HDL26020 SQUARE D, HDL26020 Datasheet - Page 37

CIRCUIT BREAKER, THERMAL MAG, 2P, 20A

HDL26020

Manufacturer Part Number
HDL26020
Description
CIRCUIT BREAKER, THERMAL MAG, 2P, 20A
Manufacturer
SQUARE D
Series
PowerPactr
Datasheet

Specifications of HDL26020

Actuator Style
Toggle
No. Of Poles
2
Current Rating
20A
Voltage Rating Vdc
250V
Voltage Rating Vac
600V
Mounting Type
DIN Rail
Terminals
Lug
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
J-Frame Circuit Breaker
with GFM Installed
Terminal strip wiring terminals must not be
be dielectric tested.
No se deben realizar pruebas dieléctricasa a
las terminalses de la tabilla de conexiones.
Les bornes de câblage de la barrette de
connexion ne doivent pas étre véroflées
diélectriquement.
© 2004–2010 Schneider Electric
All Rights Reserved
Ground-Fault Indicator
Pousser pour réinitialiser
Indicador de falla a tierra
Oprima para restablecer
Indicateur de défaut de
Ground-Fault Module
Modulo de falla a tierra
Module de défaut de mise à la terre
mise à la terre
Push to reset
®
Replace cover after adjusting/Replacer le couvercle avant aprés le réglage/Vuelva a colocar la cubierta después de ajustar
ault Indicator
Requires 120 V
HAZARD OF ELECTRICAL SHOCK OR BURN.
PELIGRO DE DESCARGA ELECTRICA O
QUEMADURAS.
DANGER DE D’CHARGE ELECTRIQUE OU DE
BRULURE.
Push-to-test
Class I Ground-fault Protection
Protección de falla a tierra clase I
Protection de défaut de mise à la terre classe I
100A 600 Vac/V
DANGER PELIGRO
20A
40A
Pick-up
max.
60A
80A
GFM150HD
100A
Replace lug cover after
wiring.
Vuelva a colocar después
de realizar el cableado
Replacez le couvre-
cosse après le câblage
!
DANGER
Delay Band
1
1=min.
2
52H
4
3
PELIGRO
4
LISTED
Circuit
Breaker
Accessory
.
®
Add-On Ground-Fault Module (GFM)
The Micrologic
equipment from damage caused by ground faults. It is an add-on module which, when connected to a
PowerPact H- or J-frame circuit breaker, provides ground-fault sensing and ground-fault relay
functions.
HD/JD ground-fault modules feature:
The GFM system requires the following:
Table 48:
See Section 6, Figure 52–53 for GFM trip curves.
Catalog No.
GFM150HD
GFM250JD
Adjustable ground-fault pickup levels.
Adjustable ground-fault time delays.
Integral ground-fault push-to-test feature.
Ground-fault indicator (mechanical for local, contacts for remote).
All GFMs are supplied for I-Line
removing the I-Line bracket.
Fault-powered (via the sensing current transformer) for electronics, shunt trip, and integral test
feature. Meets NEC 230-95(c).
A 12 Vdc shunt trip module (Catalog No. S29382) is required in the circuit breaker. This may be
field installed or factory installed when the circuit breaker is ordered with an -SN suffix.
H-frame (15–150 A) or J-frame (150–250 A) molded case circuit breaker.
Shunt trip for circuit breaker (may be factory-installed or field-installed).
Bus bar connection (terminal nut inserts) for OFF end of circuit breaker.
Optional neutral current transformer, catalog number GFM25CT (must be ordered for 4-wire
applications).
Ground-Fault Module
®
Ground-Fault Moduel (GFM) is a UL Listed circuit breaker accessory which protects
Rating
150 A
250 A
Sensitivity
20, 40, 60, 80, 100 A
40, 80, 120, 160, 200 A
®
mounting as standard, easily convertible to unit mount by
PowerPact
®
H- and J-Frame Circuit Breakers
Time Delay (Approximate)
0.2, 0.3, 0.4, 0.6 sec
0.2, 0.3, 0.4, 0.6 sec
Section 3—Accessories
06/2010
37