CIRCUIT BREAKER, THERMAL MAG, 2P, 20A

HDL26020

Manufacturer Part Number
HDL26020
Description
CIRCUIT BREAKER, THERMAL MAG, 2P, 20A
Manufacturer
SQUARE D
Series
PowerPactr
Datasheet

Specifications of HDL26020

Actuator Style
Toggle
No. Of Poles
2
Current Rating
20A
Voltage Rating Vdc
250V
Voltage Rating Vac
600V
Mounting Type
DIN Rail
Terminals
Lug
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
8
PowerPact
Section 1—General Information
1
Table 2:
Table 1:
(1) Auxiliary Switch
Suffix
AA
AB
AE
AF
(2) Alarm/Overcurrent Trip Switch
Suffix
BC
BH
BD
BJ
BE
BK
Brand
_ Square D
N Schneider
Electric
Special DC J-frame circuit breakers only.
D
G
J
L
06/2010
Frame
H H-Frame
J J-Frame
Contacts
1A/1B Standard
2A/2B Standard
1A/1B Gold
2A/2B Gold
Switch
Alarm Switch (SD) S29450
Alarm Switch (SD)
Low-level
SDE Standard
SDE Low-level
SD and SDE
Standard
SD and SDE
Low-level
240 Vac
J
100 kA
125 kA
25 kA
65 kA
Accessory Suffix Codes (Building Sequence as Listed)
Interrupting Rating
®
L
H- and J-Frame Circuit Breakers
480 Vac
Terminations
L Lugs Line/Load Side
M Lugs Line Side
P Lugs Load Side
F Bus Bar
A I-Line
S Rear Connected
N Plug-in
D Drawout
K Reverse I-Line
Interruption Rating (kA) (See Table 1)
100 kA
18 kA
35 kA
65 kA
Kit Number
S29450
S29450 (2)
S29482
S29482 (2)
Kit Number
S29452
S29450
S29451
S29452
S29451
S29450
S29451
S29452
S29451
L
Catalog Numbering
UL/CSA/NOM
Poles
2 2P
3 3P
+
+
(2) +
(2) +
600 Vac
3
14 kA
18 kA
25 kA
50 kA
(3) Shunt Trip
Suffix Kit Number Suffix
SK
SL
SA
SD
SH
SJ
SN
SO
SU
SP
SV
SR
SS
6
250 Vdc
20 kA
20 kA
20 kA
20 kA
Voltage
6 600 Vac
S29384
S29385
S29386
S29387
S29388
S29389
S29382
S29390
S29391
S29392
S29383
S29393
S29394
Amperage
150 15–15- A
250 150–250 A
000 Switch
250
500 Vdc
20 kA
(4) Undervoltage
Release UVR
UK
UL
UA
UD
UH
UJ
UN
UO
UU
UP
UV
UR
US
T
1
Kit Number
S29404
S29405
S29406
S29407
S29408
S29409
S29402
S29410
S29411
S29412
S29403
S29413
S29414
220/240 Vac 380/440/415 Vac 500/525 Vac
Trip Unit
F06 60 A H-Frame Only (No trip unit)
F15 150 A H-Frame Only (No trip unit)
F25 250 A J-Frame Only (No trip unit)
T
S15 150 A Molded Case Switch (H-Frame automatic switch)
S17 175 A Molded Case Switch (J-Frame automatic switch)
S25 250 A Molded Case Switch (J-Frame automatic switch)
C
M71 30 A H-Frame Motor Circuit Protector (MCP)
M72 50 A H-Frame Motor Circuit Protector (MCP)
M73 100 A H-Frame Motor Circuit Protector (MCP)
M74 150 A H-Frame Motor Circuit Protector (MCP)
M75 250 A J-Frame Motor Circuit Protector (MCP)
D81 500 Vdc 150–175 A J-Frame Molded Case Circuit Breaker
D82 500 Vdc 200–250 A J-Frame Molded Case Circuit Breaker
100/100 kA
125/125 kA
25/25 kA
65/65 kA
Standard Fixed Trip Unit (Suitable for reverse connection)
100% Continuous Current Rating (See page 42 for minimum enclosure size)
Complete Circuit Breaker (Frame + removable trip unit)
Voltage
24 Vac
48 Vac
120 Vac
208–277 Vac
380–480 Vac
525–600 Vac
12 Vdc
24 Vdc
30 Vdc
48 Vdc
60 Vdc
125 Vdc
250 Vdc
– – – –
100/100 kA
18/18 kA
35/35 kA
65/65 kA
IEC 647-2 Icu/Ics
Accessory Suffix Code (See Table 2)
(5) Motor Operator
Suffix
ML
MA
MD
MH
MO
MP
MR
MS
(6) IEC Style Rotary Handle
Suffix
RD10
RE10
RT10
RD20
RE20
14/14 kA
18/18 kA
25/25 kA
50/50 kA
Voltage
48/60 Vac
120 Vac
277 Vac
380/480 Vac
24/30 Vdc
48/60 Vdc
110/130 Vdc
250 Vdc
Handle Type (color)
Direct Mount (black)
Extended Door Mount (black) S29338
Telescoping (black)
Direct Mount (red)
Extended Door Mount (red)
© 2004–2010 Schneider Electric
250 Vdc
H-Frame
S29440
S29433
S29434
S29435
S29436
S29437
S29438
S29439
20 kA
20 kA
20 kA
20 kA
All Rights Reserved
I-Line
— ABC (3P)
6 CBA (3P)
1 AB (2P)
2 AC (2P)
3 BA (2P)
4 BC (2P)
5 CA (2P)
6 CB (2P)
®
500 Vdc
S31541
S31542
S31545
S31546
J-Frame
S31548
S31540
S31543
S31544
Kit
Number
S29337
S29343
S29339
S29340
Phasing
20 kA
20 kA
20 kA
20 kA

Related parts for HDL26020