HDL26020 SQUARE D, HDL26020 Datasheet - Page 9

CIRCUIT BREAKER, THERMAL MAG, 2P, 20A

HDL26020

Manufacturer Part Number
HDL26020
Description
CIRCUIT BREAKER, THERMAL MAG, 2P, 20A
Manufacturer
SQUARE D
Series
PowerPactr
Datasheet

Specifications of HDL26020

Actuator Style
Toggle
No. Of Poles
2
Current Rating
20A
Voltage Rating Vdc
250V
Voltage Rating Vac
600V
Mounting Type
DIN Rail
Terminals
Lug
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
© 2004–2010 Schneider Electric
All Rights Reserved
H-Frame Trip Curve
(l
(l
t
0
n
i
) Fixed threshold
) Fixed threshold thermal
protection against
overload
magnetic protection
against short circuits
H-Frame Trip Unit
l n
l i
J-Frame Trip Unit
25 0A
(ln )
125 0
(lm )
250 0
l
Trip System (Trip Units)
The H-frame and J-frame circuit breakers are equipped with a thermal-magnetic trip system designed
to open automatically under overload or short circuit. H-frame and J-frame circuit breakers contain
individual thermal (overload) and magnetic (short circuit) sensing elements in each pole.
The amperage ratings of the thermal trip elements are calibrated at 104°F (40°C) free air ambient
temperature. Per the National Electric Code
continuously at up to 80% of their rating.
100% Rated
Some models of the H- and J-frame circuit breakers are UL Listed to be applied at up to 100% of their
current rating. Because of the additional heat generated, the use of specially-designed enclosures
(defined on page 42) and 90°C rated wire is required when applying circuit breakers at 100% of
continuous current rating. Markings on the circuit breaker indicate the minimum enclosure size and
ventilation required. The 90°C wire must be sized according to the ampacities of the 75°C wire column
in the NEC. Circuit breakers with 100% rating can also be used in applications requiring only 80%
continuous loading.
Field-Installable Trip Units
Table 3:
H-Frame Trip Units
Table 4:
1
Table 5:
Temperature
°C
-10
0
10
20
30
40
50
60
Ampere Rating
Hold (A)
Trip (A)
15–60 A H-Frame
Amperage
15 A
20 A
25 A
30 A
35 A
40 A
45 A
50 A
60 A
Shaded areas indicate temperature rerated values, non-shaded areas are standard circuit breaker ampere ratings at 40° C (104° F).
°F
14
32
50
68
86
104
122
140
1
Temperature Rerating (H-Frame Trip Unit Thermal Protection—Long-Time)
H-Frame and J-Frame 3P Field-Installable Thermal-Magnetic Trip Unit
H-Frame Trip Unit Short Circuit Protection (Fixed) I
Cat. No.
HT3015
HT3020
HT3025
HT3030
HT3035
HT3040
HT3045
HT3050
HT3060
Rating (A) I
23
21
20
18
17
15
12
9
15–30 A
350
750
30
28
26
24
22
20
17
14
70–150 A H-Frame
Amperage
70 A
80 A
90 A
100 A
110 A
125 A
150 A
n
38
36
33
31
28
25
21
17
46
43
40
37
34
30
25
20
PowerPact
35–50 A
400
850
53
49
46
42
39
35
30
24
Cat. No.
HT3070
HT3080
HT3090
HT3100
HT3110
HT3125
HT3150
®
60
56
52
48
44
40
34
28
(NEC
68
63
59
54
50
45
38
31
®
), circuit breakers may only be applied
®
76
71
66
62
56
50
43
35
H- and J-Frame Circuit Breakers
150–250 A J-Frame
Amperage
150 A
175 A
200 A
225 A
250 A
88
83
77
72
66
60
53
46
60–90 A
800
1450
Section 1—General Information
103
97
90
84
77
70
62
53
i
112
107
101
96
88
80
72
63
Cat. No.
JT3150
JT3175
JT3200
JT3225
JT3250
123
117
111
105
98
90
80
70
100
137
131
126
120
110
86
72
100–150 A
900
1700
160
151
141
132
121
110
95
80
06/2010
180
171
161
152
139
125
109
93
221
207
194
180
165
150
131
111
9

Related parts for HDL26020