BK/HEB-BB Cooper/Bussmann, BK/HEB-BB Datasheet

FUSE HOLDER, 10.3 X 38MM

BK/HEB-BB

Manufacturer Part Number
BK/HEB-BB
Description
FUSE HOLDER, 10.3 X 38MM
Manufacturer
Cooper/Bussmann
Series
TRONr
Datasheet

Specifications of BK/HEB-BB

Voltage Rating Vdc
600V
Voltage Rating Vac
600V
Fuse Current
30A
Fuse Holder Type
Fuse Holder
No. Of Fuses
1
Fuse Size Held
13/32 X 1.1/2"
Fuse Size Imperial
13/32 X 1.1/2"
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Non-Breakaway Fuse Holders
See page 2 for breakaway holders
Catalog Symbol: HEB
Description:
Water resistant, single-pole non-breakaway in-line fuse holders
for
FNM, FNQ and KTK.
Ratings:
Volts: 600V (or less)
Amps: Up to 30A*
Agency Information:
(1)
(2)
(3)
Coupling Nut Torque: 10-20lb-in.
Part Number Explanation
Example: HEB-AK
Part Number Selection
From the table on page three, select the combination of
desired loadside and lineside terminals for the application
(define terminal type, wire size, number of wires per terminal
and whether the terminal accepts solid and/or stranded
conductors). Then in the right hand two columns, select either
the non-breakaway or breakaway holder part number to order.
Available Part Numbers
HEB-AA
HEB-AD
HEB-AY, HEB-BA
HEB-CC
HEB-LL, HEB-NN, HEB-PP
HEB-SS, HEB-TT
Insulating Boots
For insulating boots, see page 2. Insulating boots are not included
with non-breakaway holders and must be ordered
separately. They come standard with the breakaway holders.
When insulating boots are utilized, extra heat retention requires
that fuses are sized at a minimum of 200% of the RMS load
current.
*Amp rating limited by conductor size.
0908
TRON
HEB Series Single-Pole Breakaway & Non-Breakway for
UL Recognized, Guide IZLT2, File E14853
CSA Certified, Class 6225-01, File 47235
CE
• HEB = Holder series
• A = Loadside terminal (copper crimp for #12 solid
• K = Lineside terminal (copper setscrew for two #6 solid
13
3 2
copper wire)
copper wires)
˝ x 1
(1) (2) (3)
(2)
(2)
, HEB-AE
, HEB-DD
1
2
˝ midget fuses. Typical fuse types: BAF, DCM,
®
, HEB-AB
In-Line Fuse Holders
(2)
(2)
, HEB-BB
, HEB-ZA.
BU-SB08489
(2)
(2)
, HEB-AJ, HEB-AK, HEB-AL, HEB-AR,
, HEB-JJ, HEB-JK, HEB-JL, HEB-JY,
(2)
, HEB-AC
(2)
(2)
, HEB-QQ
, HEB-BC
(2)
,
(2)
(2)
, HEB-RR
, HEB-BD
(2)
(2)
,
,
Specification Data - Non-Breakaway & Loadside Breakaway
Conductor Terminals
Terminal Type
Copper Crimp
Copper Setscrew
Solid Copper Terminal for
Aluminum Wire Connector
Aluminum Crimp
Aluminum Setscrew
Page 1 of 3
Data Sheet 2127
Conductor Data
Size
#12 to #8
#12
#10
#6
#8
#4
#6
#2
#4
#20 to #18
#12 to #3
#12 to #3
#8 to #12
#10 to #4
#8
#6
#6
#4
#3, #4
#2
#1, #2
#1/0
#12 to #2
#12 to #2
13
3 2
˝ x 1
1
2
2
1
2
1
2
1
2
1
1
2
1 1
1 1
1
1
1
1
1
1
1
1
1
2
1
2
˝ Fuses
— —
— —
Catalog
Symbol
Load &
Line
(2) & (3)
A
B
C
D
E
Z
J
K
S
N
P
Q
R
T
L
Y

Related parts for BK/HEB-BB

BK/HEB-BB Summary of contents

Page 1

... For insulating boots, see page 2. Insulating boots are not included with non-breakaway holders and must be ordered separately. They come standard with the breakaway holders. When insulating boots are utilized, extra heat retention requires that fuses are sized at a minimum of 200% of the RMS load current. *Amp rating limited by conductor size. 0908 BU-SB08489 Specification Data - Non-Breakaway & ...

Page 2

... HEB-AW, RCL-A). Two insulating boots must be ordered for each holder when ordering them separately. When insulating boots are utilized, extra heat retention requires that fuses are sized at a minimum of 200% of the RMS load current. Page ...

Page 3

For HEB Holders Only Directions:To select complete holder P/N, work from left to right starting with loadside terminal options and then lineside terminal options. Then determine breakaway or non-breakaway style. Loadside Terminal No. of Terminal Solid Stranded Wire Size Wires ...