1620-1 10A ETA, 1620-1 10A Datasheet

no-image

1620-1 10A

Manufacturer Part Number
1620-1 10A
Description
FUSE, BLADE, RESETTABLE, 10A
Manufacturer
ETA
Series
1620r
Datasheet

Specifications of 1620-1 10A

Voltage Rating Vdc
12V
Fuse Current
10A
Blade Length
7.5mm
Blade Width
2.8mm
Colour
Red
External Depth
7mm
External Length / Height
25mm
External Width
13.3mm
Fuse Size
Mini Blade
Fuse Size Code
Mini Blade
Svhc
No SVHC (15-Dec-2010)
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Single pole, thermal miniaturised circuit breaker designed for automotive
applications. Fits into fuse blocks designed to ISO 8820-3, Type F.
Automatic reset (for DC 12 V only) and open circuit (modified reset to
SAE) version optional. Open circuit version ensures contacts staying
open as long as power is on. The circuit breaker will reset after the
load is removed. Particularly suitable for installation in inaccessible
locations.
Current ratings correspond to those of blade fuses. Clear colour coding
of the ratings: blade fuse and circuit breaker of the same colour have
the same rating.
Meets the requirements of SAE J553.
Protection of electrical systems of passenger cars, trucks, buses,
watercraft, extra low voltage wiring systems.
Type No.
1620
1620 - 1 - ... - 10 A
Current
rating (A)
5
7.5
10
15
20
25
30
261109
Description
Typical applications
Ordering information
Current ratings, typical voltage drop values and colour coding
single pole thermal Mini-CBE with standard characteristic curve
Version, according to SAE J553
1
2
3
3H
type 1, DC 12 V automatic reset
type 2, modified reset (not yet available)
type 3, DC 24 V with reset button
type 3*, DC 24 V with reset button and manual release facility
Voltage rating
...
1
2
standard
12 V – only for type 2
24 V – only for type 2
Current ratings
5
7.5
Thermal automotive Mini-CBE 1620-...
ordering example
Voltage
drop (mV)
< 150
< 150
< 150
< 150
< 150
< 150
< 150
10
15
20
25
Housing cap colour
light brown
brown
red
blue
yellow
white
light green
30 A
www.e-t-a.com
All dimensions without tolerances are for reference only. In the interest of improved design,
performance and cost effectiveness the right to make changes in these specifications without
notice is reserved. Product markings may not be exactly as the ordering codes. Errors and
omissions excepted.
Max. voltage rating
Current ratings
Service short-circuit
Ultimate short-circuit
breaking capacity
Shock
Corrosion
Humidity
Voltage rating
breaking capacity
Ambient temperature
Reset period for 1626-1
(at 23 °C)
Reset period for 1626-2
(at 23 °C)
Degree of protection
(IEC 60529)
Mass
It is good practice to switch off the vehicle’s ignition system before
manually releasing or re-setting the circuit breaker. Free travel of the
actuator must be ensured.
Depending on the socket used and with the 30 A device carrying a full
load, the temperatures at the terminals may rise above the allowed
SAE value.
Vibration
Technical data
1620-1
1620-1, 1620-2-1: DC 12 V
1620-2-2, 1620-3, 1620-3H:
DC 12 V, DC 24 V
1620-1, 1620-2-1: DC 14.5 V
1620-2-2, 1620-3, 1620-3H:
DC 29.0 V
DC 12 V: 5...30 A
DC 24 V: 5...25 A
300 operations at 2 x I
-40...85 °C (-40…+185 °F)
≤ 15 s
after 5 sec at rated voltage < 35 s
operating area IP40 (-3)
operating area IP50 (-1, -2)
terminal area IP00
≥ 3 break operations at 150 A, or
≥ 1 break operation at 2,000 A
10 g (57-500 Hz), ± 0.38 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
SAE-J553, Step No. 14, § 4.2.7.1.5
50 g (11 ms)
to IEC 60068-2-27, test Ea
SAE-J553, Step No. 14, § 4.2.7.1.6
24 hrs in 5 % salt mist,
to IEC 60068-2-11, test Ka
SAE-J553, Step No. 14, § 4.2.7.1.3
240 hrs in 95 % RH,
to IEC 60068-2-78, test Cab
SAE-J553, Step No. 14, § 4.2.7.1.2
approx. 3 g
1620-3
N
1620-3H
1

Related parts for 1620-1 10A

1620-1 10A Summary of contents

Page 1

... with reset button and manual release facility Voltage rating ... standard – only for type – only for type 2 Current ratings 5 7 1620 - 1 - ... - 10 A ordering example Current ratings, typical voltage drop values and colour coding Current Voltage rating (A) drop (mV) 5 < 150 7.5 < 150 10 < 150 15 < 150 20 < ...

Page 2

... Thermal automotive Mini-CBE 1620-... Dimensions 1620-1 / 1620-2 13.3 .512 GERMANY 4.5 .177 2.8 2.8 .110 10.9 .429 12.7 .500 1620-3 13.3 3.5 .524 .138 2 1.8 .079 .071 GERMANY 1620-3H 13.3 .524 4.8 3.5 .189 .138 GERMANY 2 Internal connection diagrams 1620-1 1620-2 ...

Related keywords