S506 800MA Cooper/Bussmann, S506 800MA Datasheet

FUSE, ANTISURGE, 800MA

S506 800MA

Manufacturer Part Number
S506 800MA
Description
FUSE, ANTISURGE, 800MA
Manufacturer
Cooper/Bussmann
Series
S506r
Datasheet

Specifications of S506 800MA

Voltage Rating Vac
250V
Fuse Current
800mA
Breaking Capacity
35A @ 250VAC
Fuse Size Metric
5mm X 20mm
Svhc
No SVHC (18-Jun-2010)
Approval Bodies
CSA, Semko, VDE, BSI, IMQ, MITI
Approval
RoHS Compliant
Blow Characteristic
Time Delay
Approval Category
UL
Rohs Compliant
Yes
Description
• Time delay, low breaking capacity
• Optional axial leads available
• 5mm x 20mm physical size
• Glass tube, nickel-plated brass endcap construction
• Designed to IEC 60127-2 (32mA-10A)
Agency Information
• UL Recognized Card: (32mA-10A) Guide JDYX2,
• CSA Component Acceptance: File 53787
• cURus Recognition: Guide JDYX8, File E19180
• Semko Approval, 32mA-10A
• VDE Approval, 32mA-10A
• BSI Approval, 32mA-10A
• IMQ Approval, 32mA-10A
• MITI Approval, 32mA-10A
Ordering
• Specify packaging, product, and option code
• For -R option, drop mA or A from product code
* DC Cold Resistance (Measured at <10% of rated current)
† Minimum Pre-Arching I
‡ Maximum Voltage Drop (Voltage drop was measured at 20°C ambient temperature at rated current)
32mA-100mA 2 min 200 ms 10 sec 40 ms
125mA-6.3A
Product Code
S506-32mA
S506-40mA
S506-50mA
S506-63mA
S506-80mA
S506-100mA
S506-125mA
S506-160mA
S506-200mA
S506-250mA
S506-315mA
S506-400mA
S506-500mA
S506-630mA
S506-800mA
S506-1A
S506-1.25A
S506-1.6A
S506-2A
S506-2.5A
S506-3.15A
S506-4A
S506-5A
S506-6.3A
S506-8A
S506-10A
S506-12.5A
(i.e. S506-2-R)
8A-12.5A
File E19180
In
S506 ELECTRICAL CHARACTERISTICS
2.1 In
2 min 600 ms 10 sec 150 ms 3 sec
2 min 600 ms 10 sec 150 ms 3 sec
max
2
min
t (Measured at 10 In and rated voltage)
2.75 In
Voltage
Rating
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
AC
max
min
at Rated Voltage (50Hz)
4 In
Interrupting Rating
3 sec
max
100A
125A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
40A
50A
63A
80A
10 ms 300 ms
20 ms 300 ms
20 ms 300 ms
AC
min
10 In
SPECIFICATIONS
max
Cold Resistance
Dimensions
Drawing Not to Scale
• Ratings above 6.3A have a 0.8mm diameter lead
S506 Series, Time Delay, Glass Tube
Typical DC
(ohms)*
0.268
0.191
0.131
0.064
0.046
0.039
0.029
0.024
0.018
0.013
0.010
0.009
0.007
0.005
0.004
21.7
14.2
0.66
0.46
0.37
9.5
7.1
4.5
2.8
2.0
1.3
1.0
5mm x 20mm Fuses
Pre-Arching I
(A
Minimum
2
Sec) AC†
0.0014
0.0034
0.006
0.012
0.015
0.022
0.034
0.052
0.078
0.17
0.41
0.61
0.67
150
214
192
420
812
1.0
2.2
2.7
6.7
9.7
15
25
51
88
2
t
Drop (mV)‡
Maximum
Voltage
1050
920
800
760
580
490
390
320
340
270
250
210
190
170
150
90
85
85
85
85
80
80
75
75
80
75
75

Related parts for S506 800MA

S506 800MA Summary of contents

Page 1

... Fuses Minimum Maximum Pre-Arching Voltage (A 2 Sec) AC† Drop (mV)‡ 0.0014 1050 0.0034 920 0.006 800 0.012 760 0.015 580 0 ...

Page 2

... Description BK 100 pieces of fuses packed into a cardboard carton BK1 1,000 pieces of fuses packed into a poly bag TR2 1,500 pieces of fuses packed into tape on a reel Option Code Description V Axial leads - copper tinned wire with nickel plated brass overcaps -R RoHS compliant version ...

Related keywords