G4A01216C THERMODISC, G4A01216C Datasheet - Page 14

Thermal Fuse

G4A01216C

Manufacturer Part Number
G4A01216C
Description
Thermal Fuse
Manufacturer
THERMODISC
Series
MICROTEMPr
Datasheet

Specifications of G4A01216C

Voltage Rating Vac
250V
Fuse Current
10A
Fuse Terminals
Axial Leaded
Functioning Temperature
216°C
Holding Temperature
200°C
Length/height, External
14.7mm
Voltage Ac
250V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
14
Test samples should be x-rayed before and after the soldering operation. The size of the chemical
pellet should be measured with an optical comparator or a toolmaker’s microscope to verify that
no shrinkage has occurred during the soldering operation (see figure 8). The epoxy seal should
retain its size and shape and not discolor. If the chemical pellet or the epoxy have changed size as
a result of the soldering operation more heat sinking is required.
Welding Leads
The thermal cutoff leads may also need to be heat sinked during a welding operation (see figure
9). The same precautions and tests described in the soldering section should also be followed for
welded leads.
To avoid damaging or welding internal parts, care should be taken that none of the welding current
is conducted through the TCO. A welding current of hundreds of amperes can weld the internal
parts together, resulting in the TCO failing to open.
TCO leads must be supported during the weld operation to prevent breaking the thermal cutoff
epoxy seal.
ISOLATED
LEAD
EPOXY SEAL
HEAT SINK HERE
WELD POINTS
Figure 8
Figure 9
BARREL
SPRING
TRIP
SPRING
THERMAL PELLET
CASE &
LEAD ASSEMBLY

Related parts for G4A01216C