APL11-1-66-203-M AIRPAX, APL11-1-66-203-M Datasheet

no-image

APL11-1-66-203-M

Manufacturer Part Number
APL11-1-66-203-M
Description
AIRPAX PART
Manufacturer
AIRPAX
Datasheet

Specifications of APL11-1-66-203-M

No. Of Poles
2
Current Rating
20A
Interrupting Capacity
5kA
Dielectric Strength
1.5kV
Trip Time
350s
Introduction
Single & Multi-Pole
Barriers
Configurations
Operating Characteristics
Delay Curves
Specifications
Decision Tables
|
|
|
|
|
|
|
|
168
169
171
172
174
175
180
186
APL/UPL, 205/295 Series
Magnetic Circuit Protectors

Related parts for APL11-1-66-203-M

APL11-1-66-203-M Summary of contents

Page 1

Introduction Single & Multi-Pole Barriers Configurations Operating Characteristics Delay Curves Specifications Decision Tables APL/UPL, 205/295 Series Magnetic Circuit Protectors 168 | 169 | | 171 | 172 174 | 175 | | 180 | 186 ...

Page 2

... UPL prefix. Additionally, many versions of the UPL comply with the spacing requirements covered by IEC specifications 950 and 601 and VDE specifications 0642 (EN60934) and are VDE approved and CE Compliant. Please contact the factory for assignment of a part number. http://airpax.sensata.com/ ...

Page 3

... Like all Airpax magnetic protectors, the trip current rating is not affected by ambient temperature. The 205 is recognized by UL and certified by CSA under the Component program ...

Page 4

... Two Pole 1.530 Ø 4X .156 [38.86] [3.96] 1.448 2.060 [36.78] [52.32] .432 .750 [10.97] [19.05] Three Pole 2.280 [57.91] 1.448 [36.78] .432 .750 .750 [10.97] [19.05] [19.05] Panel Mounting Tolerances: ±.005 [.13] unless noted. http://airpax.sensata.com/ Ø 6X .156 [3.96] 2.060 [52.32] ...

Page 5

... Consult factory. Barrier Style B Barrier Style C Barrier Style D Note: Tolerance ± .015 [.38] unless noted. Dimensions in brackets [ ] are millimeters. http://airpax.sensata.com/ .990 ± .020 [25.15 ± 0.51] 3.990 ± .020 [101.35 ± 0.51] .990 ± .020 [25.15 ± ...

Page 6

... Sometimes called “dump circuits” or “panic trip circuits,” these units make it possible to open main power contacts with lower power inputs from one or more sources. This configuration is becoming increasingly more important for sensitive circuitry and denser packaging in automation systems. Available in series, shunt, relay or dual coil configurations. http://airpax.sensata.com/ ...

Page 7

... LINE LINE V . COIL LOAD LOAD LOAD SHUNT DUAL TRIP COIL http://airpax.sensata.com/ .675 ± .050 (17.15 ± 1.27) .281 ± .020 (7.14 ± 0.51) .280 (7.11) 1.940 (49.28) LINE LOAD (>50 AMP) .295 [7.49] .110 [2 ...

Page 8

... .004 to .3 .016 max. .016 max. .016 max. .017 max. .017 max. .017 max. .008 to .150 .003 to .1 .003 to .08 .050 to .750 .007 to .15 .005 to .10 .017 max. .017 max. .017 max. .025 to .3 .020 to .22 .015 to . .016 to .60 http://airpax.sensata.com/ ...

Page 9

... PERCENT OF RATED CURRENT http://airpax.sensata.com/ 60Hz Delay Curves (typ) A choice of delays are offered for 60Hz applications. Delays 60 and 69 are fast acting non-delayed tripping to protect sensitive electronic equipment (not recommended where known inrush exists). Delay 61 has a short delay for general purpose applications ...

Page 10

... PERCENT OF RATED CURRENT 176 APL/UPL, 205/295 - Delay Curves 10000 1000 DELAY 64 100 .01 .001 700 800 900 1000 DELAY 66 700 800 900 1000 DELAY 100 150 200 300 400 500 600 700 800 125 PERCENT OF RATED CURRENT http://airpax.sensata.com/ 900 1000 ...

Page 11

... PERCENT OF RATED CURRENT 10000 1000 100 .01 .001 0 100 150 200 300 400 500 125 PERCENT OF RATED CURRENT http://airpax.sensata.com/ DELAY 70 600 700 800 900 1000 DELAY 71 600 700 800 900 1000 APL/UPL, 205/295 Series - Delay Curves 10000 1000 DELAY 72 100 ...

Page 12

... PERCENT OF RATED CURRENT DELAY 53 100 100 150 200 300 400 500 600 700 800 125 PERCENT OF RATED CURRENT DELAY 59 100 100 150 200 300 400 500 600 700 800 125 PERCENT OF RATED CURRENT http://airpax.sensata.com/ 900 1000 900 1000 900 1000 ...

Page 13

... PERCENT OF RATED CURRENT 10000 1000 100 .01 .001 0 100 150 200 300 400 500 125 PERCENT OF RATED CURRENT http://airpax.sensata.com/ DELAY 40 600 700 800 900 1000 DELAY 41 600 700 800 900 1000 APL/UPL, 205/295 Series - Delay Curves 10000 1000 DELAY 42 100 10 1 ...

Page 14

... Designed to meet the requirements of MIL-PrF-55629 when tested in accordance with Method 101 of MIL-Std-202. ReCOMMeNDeD TORQUe SPeCIfICATIONS grams 103 6-32 Mounting Inserts M3 Mounting Screws 10-32 Screw Terminals 1 Stud Terminals Where applicable, mechanical support must be provide to the terminals when applying torque Component Torque (in-lbs Stud Terminals http://airpax.sensata.com/ ...

Page 15

... A circuit protector with this voltage rating is intended for 277Vac per pole single phase source only usage. (e.g two or three pole breaker is marked 277Vac, all line terminals must be connected to the same phase, assuming the 277Vac is taken from line to neutral of a three phase 277/480Vac system. http://airpax.sensata.com/ Impedance (ohms) ...

Page 16

... 582 691 1975 119.0 160 495 4.1 6.2 22 1.08 1.56 5.01 .048 .068 .240 .0134 .0174 .0520 .0070 .0120 .0260 .0050 .0069 .0140 .0035 .0037 .0079 .0025 .0030 .0036 http://airpax.sensata.com/ 41, 42, 43 1195 284 12 2.72 .140 .0283 .0140 .0088 .0043 .0028 ...

Page 17

... If a two or three pole protector is marked 277Vac, all line terminals must be connected to the same phase, assuming the 277 Vac is taken from line to neutral of a three phase 277/480Vac system. http://airpax.sensata.com/ Maximum Voltage Ratings Interrupting Capacity (Amps) ...

Page 18

... Breakers mounted in the handle down position are to be tested with no current applied (per MIL-PrF-55629). Vibration Withstands 10G without tripping while carrying full rated current per MIL-Std-202, Method 204, Test Condition A. Instantaneous types (delay 40, 50, 60 and 49, 59, 69) are tested at 80% of rated current. http://airpax.sensata.com/ ...

Page 19

... Maximum Voltage Ratings 0.050 - 50 65Vdc 0.050 - 50 120Vac (50/60Hz) 0.050 - 20 240Vac (50/60Hz) 0.050 - 20 277Vac (50/60Hz) Note: AC units require maximum of 4X rated series fusing: DC units do not require series fusing. A: Two or three poles breaking http://airpax.sensata.com/ APPROxIMATe WeIgHT PeR POLe Torque (in-lbs) Ounces 3 Horsepower, Single Phase ...

Page 20

... APL/UPL, 205/295 - APL/UPL Decision Tables Notes: A The most common current values for 100% of rated current are those listed. Please consult an Airpax office orsales representa- tive for other values. B All APL/UPL protectors are constructed with stainless steel springs and plated parts. As noted in the specifications, all meet normal requirements for moisture and salt spray resistance ...

Page 21

... UPL 61- 203 APL/UPL, 205/295 Series - APL/UPL Decision Tables 187 ...

Page 22

... D For detailed barrier and wiring information, request Airpax specification AM-433. E When metric threaded inserts are specified, breakers rated at 50 amperes and below will be supplied with metric threaded terminals. For breakers rated above 50 amperes, ¼ -28 threaded terminals will be supplied. F Available in multi-pole, series only for multiphase applications. ...

Page 23

... DC-50/60Hz 150% instant trip 71* DC-50/60Hz short delay 72* DC-50/60Hz long delay 73* DC-50/60Hz motor start delay For addition of inertial delay, add an “F” to any delay number, except 40, 50, 60 and 70. *Not available above 50 amperes. http://airpax.sensata.com/ 5 Fifth Decision Maximum Voltage Rating -1 32Vdc -2 65Vdc -3 120Vac ...

Page 24

...

Related keywords