BK/HEJ-BB Cooper/Bussmann, BK/HEJ-BB Datasheet

no-image

BK/HEJ-BB

Manufacturer Part Number
BK/HEJ-BB
Description
BUSS FUSEHOLDER
Manufacturer
Cooper/Bussmann
Datasheet

Specifications of BK/HEJ-BB

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Non-Breakaway Holders
HEJ Series Catalog Symbol: HEJ-AA
HEJ-LL, HEJ-PP, and HEJ-QQ
In-Line Fuseholders, Single-Pole
Water-Resistant
Agency Information:
(1)
(2)
(3)
HEJ — For SC fuses; 35A to 60A and high voltage fuses.
Example:
A single-pole, in-line holder for a SC-40 fuse. A single #8
copper, stranded wire is on the load. Copper crimp connec-
tion desired. Two #10 copper, stranded wires are on the line
side. Copper crimp is the desired connection.
1. Choose HEJ- series.
2. Choose “A” for load side.
3. Choose “B” for line side.
Complete Part Number: HEJ-AB
Ordering Information:
Recommended Torque on Coupling Nut: 10-20 in-lb.
The only controlled copy of this Data Sheet is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is
intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change
design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information con-
tained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.
7-16-03
TRON
Single-Pole for SC-35 – 60A and HVW Fuses
HEJ-AC, HEJ-BB, HEJ-CC, HEJ-DD, HEJ-JJ, HEJ-JK,
Type HVW, ⁄Ω ™ to 6A, 1200Vac (or less).
Fuse size ⁄‹Ω £ ™∑ ≈ 2⁄Ω ¢ ∑. Holder rated 60A, 480V
UL Recognized, Guide IZLT2, File E14853
CSA Certified, Class 6225-01, File 47235
CE
HEJ
N03082
®
In-Line Fuseholders
Load
Terminal
(1) (2) (3)
Line
Terminal
, HEJ-AB,
Catalog Data — Insulating Boots
Insulating boots are not included with non-breakaway parts
and must be ordered separately. They come standard with the
breakaway series. When boots are utilized, extra heat retention
requires that fuses are sized at a minimum of 200% of the
RMS load current.
Catalog and Specification Data
Conductor Terminals
Terminal Type
Copper Crimp
Copper Set-Screw
Aluminum Crimp
Aluminum Set-Screw
Conductor Data
Size
#12 to #8
#12
#10
#6
#4
#8
#4
#6
#2
#12 to #3
#12 to #2
#6
#4
#3, #4
#2
#12 to #2
Catalog
Numbers
2A0660
2A0661
1
2
2
1
1
2
1
2
1
1
2
1
1
1
1
1
Bussmann
Single Conductor
Two Conductor
Form No. HEJ Series
Series
Data Sheet: 2123
Type
HEJ
Catalog
Symbol
Load &
Line
Page 1 of 1
A
B
C
D
J
K
P
Q
L
®