L4006D5RP Littelfuse Inc, L4006D5RP Datasheet

TRIAC, SENSITIVE GATE, 400V 6A DPAK

L4006D5RP

Manufacturer Part Number
L4006D5RP
Description
TRIAC, SENSITIVE GATE, 400V 6A DPAK
Manufacturer
Littelfuse Inc
Datasheet

Specifications of L4006D5RP

Peak Repetitive Off-state Voltage, Vdrm
400V
Gate Trigger Current Max (qi), Igt
5mA
On State Rms Current It(rms)
6A
Peak Non Rep Surge Current Itsm 50hz
50A
Holding Current Max Ih
10mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
E1
General Description
Teccor's line of sensitive gate triacs includes devices with current
capabilities through 8 A. Voltage ranges are available from 200 V
to 600 V. This line features devices with guaranteed gate control
in Quadrants II and IV as well as control in the commonly used
Quadrants I and III. Four-quadrant control devices require
sensitive gate triacs. They can be controlled by digital circuitry
where positive-only or negative-only pulses must control AC
current in both directions through the device. Note that triacs with
low I
characteristics.
The sensitive gate triac is a bidirectional AC switch and is gate
controlled for either polarity of main terminal voltage. It is used
primarily for AC switching and phase control applications such as
motor speed controls, temperature modulation controls, and
lighting controls.
The epoxy TO-92 and TO-220 configurations feature Teccor's
electrically-isolated construction where the case or mounting tab
is internally isolated from the semiconductor chip and lead
attachments. Non-isolated epoxy TO-202 packages are available
as well as TO-251 and surface mount TO-252 (D-Pak). Tape-
and-reel capability and tube packing also are available. See
“Packing Options” section of this catalog.
All Teccor triacs have glass-passivated junctions. This glassing
process prevents migration of contaminants and ensures long-
term device reliability with parameter stability.
©2004 Littelfuse, Inc.
Thyristor Product Catalog
GT
values in Quadrants II and IV will have lower dv/dt
TO-202
Compak
3-lead
TO-92
TO-252
D-Pak
*TO-220
Isolated
Sensitive Triacs
E1 - 1
Variations of devices covered in this data sheet are available for
custom design applications. Consult factory for more information.
TO-251
Features
Compak Sensitive Gate Triac
V-Pak
RoHS Compliant
Electrically-isolated packages
Glass-passivated junctions ensure long device
reliability and parameter stability
Voltage capability — up to 600 V
Surge capability — up to 80 A
Four-quadrant gating guaranteed
Surface mount package — 0.8 A and 1 A series
New small profile three-leaded Compak package
Packaged in embossed carrier tape with 2,500
devices per reel
Can replace SOT-223
(0.8 A to 8 A)
MT2
http://www.littelfuse.com
E1
+1 972-580-7777
G
R o HS
MT1

Related parts for L4006D5RP

L4006D5RP Summary of contents

Page 1

... Quadrants II and IV as well as control in the commonly used Quadrants I and III. Four-quadrant control devices require sensitive gate triacs. They can be controlled by digital circuitry where positive-only or negative-only pulses must control AC current in both directions through the device. Note that triacs with low I values in Quadrants II and IV will have lower dv/dt GT characteristics ...

Page 2

... Sensitive Triacs I Isolated T(RMS) (11) G MT1 MT1 MT2 MT2 G TO-92 Compak MAX See “Package Dimensions” section for variations. (12) L2X8E3 L2X3 L4X8E3 L4X3 L6X8E3 L6X3 L2X8E5 L2X5 L4X8E5 L4X5 0.8 A L6X8E5 L6X5 L2X8E6 L4X8E6 L6X8E6 L2X8E8 L4X8E8 L6X8E8 L201E3 L2N3 L401E3 ...

Page 3

... Sensitive Triacs 2 t dv/ di/dt gt (1) (9) Volts/µSec µSec Amps Sec Amps/µSec 100 °C TYP TYP 20 2.8 0. 2.8 0. 2 0.41 20 ...

Page 4

... Sensitive Triacs I Isolated T(RMS) (11) G MT1 MT2 TO-220 MAX See “Package Dimensions” section for variations. (12) L2006L5 L4006L5 L6006L5 6 A L2006L6 L4006L6 L6006L6 L2006L8 L4006L8 L6006L8 L2008L6 L4008L6 8 A L6008L6 L2008L8 L4008L8 L6008L8 Specified Test Conditions di/dt — Maximum rate-of-change of on-state current; I ...

Page 5

... Gate Characteristics Teccor triacs may be turned on between gate and MT1 terminals in the following ways: with reference to MT1 • In-phase signals (with standard AC line) using Quadrants I and III • Application of unipolar pulses (gate always positive or nega- tive), using Quadrants II and III with negative gate pulses and ...

Page 6

... Sensitive Triacs Electrical Isolation Teccor’s isolated triac packages withstand a minimum high potential test of 2500 V ac rms from leads to mounting tab over the device's operating temperature range. The following isolation table shows standard isolation ratings. Electrical Isolation from Leads to Mounting Tab ...

Page 7

... Case Temperature ( ˚ versus Case Temperature 4.0 3.0 2.0 1.0 0 -65 -40 -15 +25 +65 Case Temperature ( ˚C C versus Case Temperature 7 ˚ MAX GT 5 MAX GT 4 MAX 3 MAX GT 2.0 1 100 DC Gate Trigger Current ( http://www.littelfuse.com +1 972-580-7777 Sensitive Triacs +110 +125 +110 +125 ...

Page 8

... Sensitive Triacs 200 SUPPLY FREQUENCY Sinusoidal 150 LOAD: Resistive RMS On-state Current: [I 100 Rated Value at Specified Case Temperature Figure E1.9 Peak Surge Current versus Surge Current Duration CURRENT WAVEFORM: Sinusoidal 1.5 LOAD: Resistive or Inductive CONDUCTION ANGLE: 360˚ 1 0.25 ...

Related keywords