BTHQ21603V-SRE WC BATRON, BTHQ21603V-SRE WC Datasheet

LCD MODULE, ALPHANUMERIC, 16X2

BTHQ21603V-SRE WC

Manufacturer Part Number
BTHQ21603V-SRE WC
Description
LCD MODULE, ALPHANUMERIC, 16X2
Manufacturer
BATRON
Datasheet

Specifications of BTHQ21603V-SRE WC

No. Of Digits / Alpha
32
Character Count X Line
16 X 2
Character Size
3.15mm
Supply Voltage
5V
Display Area Width
36mm
Display Area Height
10mm
Operating Temperature
RoHS Compliant
Display Mode
Reflective
Backlighting Colour
Yellow
Rohs Compliant
Yes
Operating Temperature Range
0°C To +50°C
Feb/2002
BATRON
BTHQ 21603VSS-01
1/12
DOCUMENT NUMBER AND REVISION
VL-FS-BTHQ 21603VSS-01 REV.B
(BTHQ 21603V-SRE-CONN.)
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de

Related parts for BTHQ21603V-SRE WC

BTHQ21603V-SRE WC Summary of contents

Page 1

... BATRON DOCUMENT NUMBER AND REVISION DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119 VL-FS-BTHQ 21603VSS-01 REV.B (BTHQ 21603V-SRE-CONN.) Feb/2002 BTHQ 21603VSS-01 1/12 www.data-modul.de ...

Page 2

... BATRON DISTRIBUTION LIST: MARKETING DOCUMENT REVISION HISTORY 1: DOCUMENT DATE REVISION FROM TO A 2002.01. 2002.01.14 DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119 DESCRIPTION First Release Items were updated: 1.) (Page 4, point 1) “(CON-IL-402)” was added. 2.)(Page 4, point 2) “ ...

Page 3

... BATRON 1. GENERAL DESCRIPTION 2. MECHANICAL SPECIFICATIONS 3. ABSOLUTE MAXIMUM RATINGS 3.1 ELECTRICAL MAXIMUM RATINGS (Ta=25°C) 3.2 ENVIRONMENTAL CONDITION 4. ELECTRICAL SPECIFICATIONS 4.1 INTERFACE SIGNALS 4.2 TYPICAL ELECTRICAL CHARACTERISTICS 4.3 TIMING SPECIFICATIONS 4.4 TIMING DIAGRAM OF VDD AGAINST V0 4.5 CORRESPONDENCE BETWEEN CHARACTER CODES AND CHARACTER PATTERNS (NOVATEK STANDARD NT3881D-01) DATA MODUL AG Landsberger Str. 322 80687 Mü ...

Page 4

... BATRON 1. General Description • 16 characters (5x8 dots lines STN Positive Yellow Reflective Dot Matrix LCD module. • Viewing Angle: 6 O’clock direction. • Driving scheme: 1/16 Duty, 1/5 bias. • ‘NOVATEK’ NT3881DH-01/AI (Die form) LCD Controller and Driver or equivalent • ’SAMSUNG’ KS0065B-PCC (Die form) or equivalent 40-Channel Segment/Common Driver for Dot Matrix LCD. • ...

Page 5

... BATRON DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119 BTHQ 21603VSS-01 5/12 www.data-modul.de ...

Page 6

... BATRON 3. Absolute Maximum Ratings 3.1 Electrical Maximum Ratings( ºC) Parameter Power Supply voltage (Logic) Power Supply voltage (LCD drive) Input voltage Note: The modules may be destroyed if they are used beyond the absolute maximum ratings. All voltage values are referenced to VSS = 0V. ...

Page 7

... BATRON 4. Electrical Specifications 4.1 Interface signals Pin No. Symbol 1 VSS Ground(0V). 2 VDD Power supply for logic (+5V Power supply for LCD driver 4 RS Register Select Input: “High” for Data register (for read and write) ”Low” for Instruction register (for write), 5 R/W Read/Write signal: ” ...

Page 8

... BATRON 4.2 Typical Electrical Characteristics ° ° ° ° C, VDD = 5V± ± ± ± 5%, VSS=0V. Parameter Supply voltage (Logic) Supply voltage (LCD) Input signal voltage 1 for E,DB0-DB7,R/W,RS. Input signal voltage 2 for OSC1. Supply Current (Logic & LCD) Supply Current (LCD) Note (1) : There is tolerance in optimum LCD driving voltage during production and it will be within the specified range. DATA MODUL AG Landsberger Str. 322 80687 Mü ...

Page 9

... BATRON 4.3 Timing Specifications °C To +50 °C , VDD = +5V±5%, VSS = 0V. Refer to Fig. 2, the bus timing diagram for write mode. Parameter Enable cycle time Enable ”High” level pulse width Enable rise time Enable fall time RS, R/W set-up time RS, R/W address hold time ...

Page 10

... BATRON Figure 2: Bus write operation sequence (Writing data from MPU to NT3881). Figure 3: Bus read operation sequence (Reading out data from NT3881 to MPU). DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119 BTHQ 21603VSS-01 10/12 www.data-modul.de ...

Page 11

... BATRON 4.4 Timing Diagram of VDD against V0. Power on sequence shall meet the requirement of Figure 4, the timing diagram of VDD against V0. LOGIC SUPPLY VOLTAGE 0V OV LCD SUPPLY VOLTAGE Figure 4: Timing diagram of VDD against V0. DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119 ...

Page 12

... BATRON 4.5 Correspondence between Character Codes and Character Patterns (NOVATEK Standard NT3881D-01) DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119 BTHQ 21603VSS-01 12/12 www.data-modul.de ...

Related keywords