VFD MODULE, 140X16

GU140X16G-7806A

Manufacturer Part NumberGU140X16G-7806A
DescriptionVFD MODULE, 140X16
ManufacturerNoritake Company Inc
GU140X16G-7806A datasheet
 

Specifications of GU140X16G-7806A

Resolution140 X 16Viewing Area (h X W)11.45mm X 69.85mm
Supply Current250mASupply Voltage Range4.75V To 5.25V
Operating Temperature Range-40°C To +85°CCharacter FormatDot Graphic
Character Type5x7Lead Free Status / RoHS StatusLead free / RoHS Compliant
1
Page 1
2
Page 2
3
Page 3
4
Page 4
5
Page 5
6
Page 6
7
Page 7
8
Page 8
Page 6/8

Download datasheet (259Kb)Embed
PrevNext
Dot Graphic VFD Module
DISPLAYING GRAPHICS
Graphical images can be displayed on the VFD module in either a horizontal or vertical byte orientation. After each graphical data write, the cursor
is automatically advanced. All graphical data is contained within the defined area. Unused bits are masked where the screen area is not a byte
multiple
The following example displays a simple graphical image. The graphical data orientation is
set to horizontal data format, with a vertical cursor movement. Command bytes that are
underlined should be sent with RS line low.
AREA COMMAND
AREA CO-ORDINATES
HORIZONTAL FORMAT
F1H
30H 04H 37H 0BH
‘h’
The next example displays a simple graphical image using a vertical data format, with a
horizontal cursor movement. Command bytes that are underlined should be sent with RS
line low.
AREA COMMAND
AREA CO-ORDINATES
VERTCAL FORMAT
F1H
50H 00H 63H 0FH
‘v’
AREA COMMANDS
The VFD module contains commands to fill, clear and invert defined areas of the display. Also an outline command is available to draw rectangles
around objects.
The following example displays three options for the user to select, each option is contained within a box with a shadow effect. Drawing horizontal
and vertical lines using the fill area command creates the shadow effect. Command bytes that are underlined should be sent with RS line low.
5x7 FONT
1-PIXEL SPACING
SET CURSOR
F2H ‘B’
F2H ‘1’
F0H 0DH 0BH
F0H 36H 0BH
F0H 65H 0BH
SET AREA
TOP LEFT
BOTTOM RIGHT
F1H
0AH 02H
2CH 0CH
F1H
33H 02H
55H 0CH
F1H
5CH 02H
7EH 0CH
SET AREA
HORIZONTAL LINE
FILL
SET AREA
F1H 0BH 0DH 2DH 0DH
‘F’
F1H 2DH 03H
F1H 34H 0DH
56H 0DH
‘F’
F1H 56H 03H
F1H 5DH 0DH 7FH 0DH
‘F’
F1H 7FH 03H
The next example uses the invert area command to select one of the options.
SET AREA
TOP LEFT
BOTTOM RIGHT
F1H
5DH 03H
7DH 0BH
NORITAKE ITRON VFD MODULES
GRAPHIC DATA
1CH 5CH 48H 3EH 1DH 1DH 14H 36H
GRAPHIC DATA
00H 00H 00H 00H 07H 04H C7H FEH 72H 73H
32H 3EH 3FH 1DH 00H 00H 00H 00H 00H 00H
00H 3CH 42H 81H B9H C1H 42H 7CH 20H D8H
FCH 3CH FCH CAH 49H B1H 89H 42H 3CH 00H
DISPLAY TEXT
‘SETUP’
‘PRINT’
‘RUN’
OUTLINE
‘O’
‘O’
‘O’
HORIZONTAL LINE
FILL
2DH 0DH
‘F’
56H 0DH
‘F’
7FH 0DH
‘F’
INVERT
‘I’
GU140x16G-7806A
MSB
- 1CH
- 5CH
- 48H
- 3EH
- 1DH
- 1DH
- 14H
- 36H
Graphic Image using horizontal data
MSB
Graphic Image using vertical data
Displaying graphic images in vertical and horizontal format.
Display options with simple graphic text write.
Boxes created using the ‘Set Area Outline’ command.
Drop Shadows created with the ‘Fill Area’ command.
Option ‘Run’ selected with the ‘Invert Area’ command.
GU140x16G-7806A