APD199N-A-24V IDEC, APD199N-A-24V Datasheet - Page 2

LAMP, INDICATOR, INCAND, AMB

APD199N-A-24V

Manufacturer Part Number
APD199N-A-24V
Description
LAMP, INDICATOR, INCAND, AMB
Manufacturer
IDEC
Datasheet

Specifications of APD199N-A-24V

Supply Voltage
24V
Current Rating
0.020A
Mounting Hole Dia
30mm
Color
Amber
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Oiltight Switches & Pilot Devices
Specifi cations
Mechanical-Electrical Specifi cations
Contact Ratings
Conforming to Standards
Approvals
Operating Temperature
Vibration Resistance
Shock Resistance
Electric Shock Protection
Degree of Protection
Mechanical Life
Pollution Degree
Rated Operational Characteristics
Rated Insulation Voltage
Rated Switching Overvoltage
Rated Impulse Withstanding Voltage
Rated Thermal Current
Minimum Switching Capacity
Contact Operation
Operating Force
Terminal Referencing
Recommended Terminal Torque
External Short-Circuit Protection
Applicable Wire Size
Contact Resistance
Contact Gap
Lamp Ratings
Maximum Inrush Current
Contact Material
Contact Ratings by Utilization Category IEC 60947-5-1
Operational Voltage
Operation Current
(conforming to IEC60947-1)
AC 50/60 Hz
DC
AC-12 Control of resistive loads & solid state loads
AC-15 Control of electromagnetic loads (> 72VA)
DC-12 Control of resistive loads & solid state loads
DC-13 Control of electromagnets
AC-15: A600 or Ue = 250V, le = 3A (NO, NC, NO-EM, NC-LB)
DC-13: P600 or Ue = 125V, le = 1.1A (NO, NC)
DC-13: Q600 or Ue = 125V, le = 0.9A (NO-EM, NC-LB)
600V
Less than 4kV, conforming to IEC60947-1
4kV for contact circuit
2.5kV for lamp circuit
10 Amp
5 mA at 3V AC/DC
Slow break NC or NO, self-cleaning
Flush and extended pushbuttons—with 1NO or 1NC contact: 6.2±2N (momentary),
7.0±2N (maintained)
Additional contacts—1NO or 1NC: +3.2N (momentary), + 3.3N (maintained)
Conforming to CENELEC EN50005
0.8 N m (7.1 in lb.)
10A 250V fuse conforming to IEC60269-1
Minimum 1 x 22 AWG, max. 2 x 14 AWG or 1 x 12 AWG
Initial contact resistance of 50mΩ or less
4mm (NO and NC)
2mm (NO-EM and NC-LB)
Incandescent: 1 W
LEDs: 6V: 17mA, 12V: 11mA, 24V: 11mA, / 120, 240V: 10mA
40 A (40 msec)
Silver
EN60947-1, EN60947-5-1, VDE0660-200, UL508, CSA C22-2 No.14
CSA: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbut-
tons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V)
UL: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons
with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V)
TÜV: pushbuttons and selector switches: A600=P600 (NO, NC)/Q600 (NO-EM, NC-LB) pilot lights and illuminated pushbuttons, direct supply
pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V)
Operation: –25 to +50°C (without freezing)
Storage: –40 to +70°C (without freezing)
10 to 55Hz, 98m/sec
980m/sec
Class 0 conforming to IEC60536
IP65 (from front of the panel) (conforming to IEC60529)
IP54 (key switches)
NEMA 1, 2, 3, 3R, 3S, 4, 4X, 5, 12, 13 (conforming to NEMA ICS6-110)
Momentary pushbuttons: 5,000,000 (900 operations per hour)
All other switches: 500,000
3 for switches not using a transformer
2 for switches using a transformer
2
(100g) conforming to IEC6068-2-7
USA: 800-262-IDEC
2
(10g) conforming to IEC6068-2-6
Contact Ratings by Utilization Category
AC-15 (A600)
DC-13 (P600)
Canada: 888-317-IDEC
ø30mm - TWTD Series
24V
10A
10A
8A
5A
48V
5A
2A
50V
10A
7A
110V
10A
5A
2.2A
1.1A
220V
6A
3A
1.1A
0.6A
440V
2A
1A
611

Related parts for APD199N-A-24V