ACPL-M61T-500 Avago Technologies US Inc., ACPL-M61T-500 Datasheet - Page 3

Automotive 10MBd Coupler Tape Reel

ACPL-M61T-500

Manufacturer Part Number
ACPL-M61T-500
Description
Automotive 10MBd Coupler Tape Reel
Manufacturer
Avago Technologies US Inc.
Series
R²Coupler™r
Datasheets

Specifications of ACPL-M61T-500

Voltage - Isolation
3750Vrms
Number Of Channels
1, Unidirectional
Current - Output / Channel
50mA
Data Rate
10MBd
Propagation Delay High - Low @ If
46ns @ 6.5mA
Current - Dc Forward (if)
20mA
Input Type
DC
Output Type
Open Collector
Mounting Type
Surface Mount
Package / Case
6-SOIC (0.173", 4.40mm Width) 5 Leads
Number Of Elements
1
Forward Voltage
1.85V
Forward Current
20mA
Output Current
50mA
Isolation Voltage
3750Vrms
Package Type
SOIC
Operating Temp Range
-40C to 125C
Power Dissipation
85mW
Propagation Delay Time
75ns
Pin Count
5
Mounting
Surface Mount
Reverse Breakdown Voltage
5V
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ACPL-M61T-500E
Manufacturer:
AVAGO
Quantity:
10 000
Part Number:
ACPL-M61T-500E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Recommended Pb-Free IR Profile
Recommended reflow condition as per JEDEC Standard, J-STD-020 (latest revision).
Note: Non-halide flux should be used.
Regulatory Information
The ACPL-M61T is approved by the following organizations:
UL
Approved under UL 1577, component recognition
program up to V
CSA
Approved under CSA Component Acceptance Notice #5.
IEC/EN/DIN EN 60747-5-2 Insulation Characteristics*
*
Insulation and Safety Related Specifications
3
Description
Installation classification per DIN VDE 0110/1.89, Table 1
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
V
Input to Output Test Voltage, Method a*
V
Highest Allowable Overvoltage (Transient Overvoltage t
Safety-limiting values – maximum values allowed in the event of a failure.
Insulation Resistance at T
Parameter
Minimum External Air
Gap (Clearance)
Minimum External
Tracking (Creepage)
Minimum Internal Plastic
Gap (Internal Clearance)
Tracking Resistance
(Comparative Tracking
Index)
Isolation Group
(DIN VDE0109)
IORM
IORM
Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, (IEC/EN/
DIN EN 60747-5-2) for a detailed description of Method a and Method b partial discharge test profiles.
for rated mains voltage ≤ 150 V
for rated mains voltage ≤ 300 Vrms
for rated mains voltage ≤ 600 V
Case Temperature
Input Current
Output Power
x 1.875=V
x 1.6=V
PR
, Type and Sample Test, t
PR
ISO
, 100% Production Test with t
= 4000 V
S
, V
IO
Symbol
L(101)
L(102)
CTI
RMS
= 500 V
rms
rms
ACPL-M61T Units
≥ 5
≥ 5
0.08
175
IIIa
m
=10 sec, Partial discharge < 5 pC
m
=1 sec, Partial discharge < 5 pC
mm
mm
mm
V
ini
= 60 sec)
Conditions
Measured from input terminals to output terminals, shortest distance
through air.
Measured from input terminals to output terminals, shortest distance
path along body.
Through insulation distance conductor to conductor, usually the
straight line distance thickness between the emitter and detector.
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0109)
IEC/EN/DIN EN 60747-5-2
Approved under:
IEC 60747-5-2:1997 + A1
EN 60747-5-2:2001 + A1
DIN EN 60747-5-2 (VDE 0884 Teil 2)
Symbol
V
V
V
V
T
I
P
R
S, INPUT
S
IORM
PR
PR
IOTM
S, OUTPUT
S
Characteristic
I – IV
I – III
I – II
55/125/21
2
567
1063
907
6000
175
230
600
>10
9
Unit
V
V
V
V
°C
mA
mW
:
peak
peak
peak
peak

Related parts for ACPL-M61T-500