119379-52 AMETEK, 119379-52 Datasheet

BLOWER, 127MM, 24VDC, INT, HF

119379-52

Manufacturer Part Number
119379-52
Description
BLOWER, 127MM, 24VDC, INT, HF
Manufacturer
AMETEK
Series
Minijammerr
Type
Canisterr
Datasheets

Specifications of 119379-52

External Height
68.58mm
Current Type
DC
Supply Voltage
24VDC
Flow Rate
21l/s
Depth
71.63mm
External Length / Height
68.58mm
Flow Rate Imperial
45cu.ft/min
Flow Rate Max
21l/s
Air Flow
44.6 CFM
Diameter, Inlet
1.5 "
Dimensions
127Dia x 71.63L mm
Special Features
Speed Control
Static Pressure
24.9 in.-H2O
Temperature, Operating, Maximum
+45 °C
Temperature, Operating, Minimum
0 °C
Termination
Terminals
Voltage, Rating
24 VDC
Outer Diameter
127mm
Flow Rate - Imperial
45cu.ft/min
Flow Rate - Metric
76m3/h
Rohs Compliant
Yes
External Depth
71.63mm
Power Connection Type
Terminals
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
5.0” (127mm) BLDC Low-Voltage Blower
Blower Data
Voltage Input
Stages
Pressure, Max. (Sealed Pressure)
Flow Rate, Max. (Open Flow)
Drive Electronics
Air Flow
0 CFM
10 CFM
20 CFM
30 CFM
40 CFM
* These part numbers are available through AMETEK Rotron distributors. (Models 150017 and 150016 have slight dimensional changes. Consult AMETEK
NOTES:
• Temperature: Working Air: 0°C to 45°C, Ambient Air: 0°C to 45°C, Storage Air: -40°C to 85°C
• Dielectric Testing: 500 volts AC RMS 60Hz applied for one second between input pins and ground, one milliamps leakage max.
• Speed Control: Internal – E (Electrical): Pulse Width Modulated or Analog input voltage (User Supplied), 0 to 5 Volts DC Nominal
• Optional fan cover shell with molded air inlet tube available (see above drawing)
Marketing and Sales for additional information on these part numbers.)
External - These blowers require a 3 phase electronic commutated input to operate. A separate blower controller provides this input and
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed.
speed control. Refer to the controller section (page 84) of this catalog for additional information.
Internal or External
Measure
in. H
in. H
in. H
in. H
in. H
in. H
Unit
L/sec
mBar
CFM
VDC
2
2
2
2
2
2
O
O
O
O
O
O
(150017)*
External
119380
12.5
11.7
7.6
2.3
12
12
30
34
16
1
Typical Performance Points
119381 (M)*
119382 (E)*
Internal
12.5
11.7
24
7.6
2.3
12
12
30
34
16
1
Standard Flow
Pressure
(150016)*
External
119383
Part Number
12.5
11.7
7.6
2.3
24
12
30
34
16
1
119384 (M)*
119385 (E)*
Internal
12.5
11.7
7.6
2.3
24
12
30
34
16
1
External
119375
24.3
22.0
18.4
10.8
3.5
24
24
60
45
21
1
12/24 VDC
High Output
119378 (M)*
119379 (E)*
Internal
24.3
22.0
18.4
10.8
3.5
24
24
60
45
21
1

Related parts for 119379-52

119379-52 Summary of contents

Page 1

... External Internal External Typical Performance Points Pressure 12.5 12.5 12.5 11.7 11.7 11.7 7.6 7.6 7.6 2.3 2.3 2.3 24 12/24 VDC High Output 119384 (M)* 119378 (M)* 119385 (E)* 119375 119379 (E Internal External Internal 12.5 24.3 24.3 11.7 22.0 22.0 7.6 18.4 18.4 2.3 10 ...

Page 2

... Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed for and should not be used in medical life support applications ...

Related keywords