MCPF-031-14-11 MULTICOMP, MCPF-031-14-11 Datasheet

PELTIER COOLER, 19W

MCPF-031-14-11

Manufacturer Part Number
MCPF-031-14-11
Description
PELTIER COOLER, 19W
Manufacturer
MULTICOMP
Datasheet

Specifications of MCPF-031-14-11

Transducer Function
Thermoelectric Cooler
Power Rating
19W
Internal Resistance
0.41ohm
Current Max @ Diff Temperature Max
8.5A
Voltage Max @ Diff Temperature Max
3.8V
Temperature Difference Max
70°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Specification : TE -module PF-031-14-11
1. Scope
2. Specification
1—1
2-1
1—2
Revision of these specifications is carried out after consent.
Parameters
Maximum. compress
This specification is applied to Multicomp thermoelectric modules
solder melting point
Internal resistance
Note-1 Measured by AC 4-terminal method at 25℃.
Note-2 Maximum current at ⊿Tmax.
Note-3 Maximum voltage at ⊿Tmax.
Note-4 Maximum cooling capacity at Imax.,Vmax. and ⊿T=0℃.
Note-5 Maximum temperature difference at Imax.,Vmax. and Q=0W.
(Maximum parameters are measured in a vacuum 1.3P)
Note-6 The solder melting point of thermoelectric module
Note-7 Recommended maximum compression (not destruction limit)
⊿Tmax.
Qmax.
Vmax.
Imax.
Product:Thermoelectric module
Part Number:PF-031-14-11
SPECIFICATION
.
Parameters
Th=25℃
19.0 W
70℃
0.41 Ω ± 10%
Issue 2
232 ℃
1MPa
3.8 V
8.5 A
Issued: 29/05/2008
Note-7
Remarks
Note-1
Note-5
Note-6
Note-2
Note-3
Note-4
1 / 2

Related parts for MCPF-031-14-11

MCPF-031-14-11 Summary of contents

Page 1

... Specification : TE -module PF-031-14-11 Product:Thermoelectric module Part Number:PF-031-14-11 1. Scope 1—1 This specification is applied to Multicomp thermoelectric modules 1—2 Revision of these specifications is carried out after consent. 2. Specification 2-1 Parameters Internal resistance Imax. Vmax. Qmax. ⊿Tmax. solder melting point Maximum. compress Note-1 Measured by AC 4-terminal method at 25℃ ...

Page 2

Recommendations: - maximum temperature for short time: 200 °С - operation temperature up to 150°С for long lifetime; - ON/OFF cycling mode reliability at high temperature - recommended operation current not higher than 0.7 of Imax - preferable ...

Page 3

...

Related keywords