ZENSTARTER02V2 Omron, ZENSTARTER02V2 Datasheet

no-image

ZENSTARTER02V2

Manufacturer Part Number
ZENSTARTER02V2
Description
ZEN STARTER KIT AC I/O
Manufacturer
Omron
Datasheet

Specifications of ZENSTARTER02V2

Accessory Type
Starter Kit
Kit Contents
CPU Unit (ZEN-10C1DR-D-V2), Connecting Cable, ZEN Support Software And Manual
Please read and understand this catalog before purchasing the
products. Please consult your OMRON representative if you have any
questions or comments. Refer to “Warranty and Application
Considerations” on page 36, and “Precautions for Safe Use” on page 34.
Even Broader Applications with Increased
Functionality and Higher Precision
• Increased functionality in a compact body (70 mm wide 90 mm
• Easy programming is available using the LCD and operation
• This single Unit easily provides relay, timer, counter, and time
• Expansion is easy with Expansion I/O Units, allowing up to 44
• Economy-type and Communications-type CPU Units have been
• Improved Weekly Timers (See note 1.)
• Select from two power supply options:
Note: 1. Not supported for ZEN-@C2@@-@-V2 models.
Features
Saves Space, Wiring, and Installation Steps
• Versatile functionality in a compact body (70 mm wide
• This single Unit easily provides relay, timer, counter, and time
high).
switch functions. Wiring work is greatly reduced because separate
wiring is not required for devices such as timers and counters.
high).
buttons. (See note 1.)
switch functions.
I/O points. (See note 2.)
added to series.
Increased timing accuracy with a monthly deviation of ±15 s
max. Multiple-day operation and pulse output operation have
been added.
100 to 240 VAC or 12 to 24 VDC.
Programmable Relay
ZEN V2 Units
Easy and Simple Programming for Automatic Small-scale Control
2. When using CPU Units with 20 I/O points.
70 mm
90 mm
90 mm
Easy Programming
The LCD screen comes with 8 operation buttons on the front panel to
enable programming in ladder view format. The LCD screen also has
a backlight, making it easier to see when the ZEN is used in dark
locations.
Note: Not supported for ZEN-@C2@@-@-V2 models.
The information in this document applies to V2 Units.
Refer to page 28 for details on differences with previous
products.
Programmable Relay
ZEN V2 Units
1

Related parts for ZENSTARTER02V2

ZENSTARTER02V2 Summary of contents

Page 1

... Programmable Relay ZEN V2 Units Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to “Warranty and Application Considerations” on page 36, and “Precautions for Safe Use” on page 34. Even Broader Applications with Increased Functionality and Higher Precision • ...

Page 2

... ZEN. Note: For notebook computers that do not have an RS-232C serial port, connect the computer to the ZEN by connecting an OMRON CS1W-CIF31 USB-Serial Conversion Cable to the ZEN-CIF01 Connecting Cable. Other Versatile Functions • Use of a Memory Cassette makes it easy to copy and save programs. • ...

Page 3

Series Configuration CPU Units Power supply voltage: 100 to 240 VAC VDC, Output: Relay, transistor output With LCD display, operation buttons, and calendar/clock function 10 I/O points Communications type Standard LCD type Economy type ZEN-10C1@ ZEN-10C3@ Expansion ...

Page 4

... ZEN Operation Manual (Cat. No. Z211) ZEN Communications Manual (Cat. No. Z212) ZEN Support Software Operation Manual (Cat. No. Z184-E1-03) The PDF versions of these manuals can be downloaded from the following website. ZEN Website http://www.zen.omron.co.jp/eng/index.html ZEN V2 Units 4 Programmable Relay 3. Input type ...

Page 5

Ordering Information List of Models CPU Units and Expansion I/O Units Unit Name No. of LCD I/O display points CPU Standard 10 Yes 100 to 240 VAC Units LCD type VDC 20 100 to 240 VAC 12 ...

Page 6

... CPU Unit version combination. For details, refer to “Memory Cassette and CPU Unit Combinations” on page 33. 2. Standard LCD-type, Economy-type, and Communications-type CPU Units (i.e., excluding ZEN-@C2@@-@-V2 models). 3. LED-type CPU Unit without display (i.e., ZEN-@C2@@-@-V2 models). Mounting Accessories (Order Separately) Name Specifications Mounting Track 50 cm (l) 7 ...

Page 7

Specifications Ratings Item Rated supply voltage 100 to 240 VAC, 50/60 Hz Operating voltage range 85 to 264 VAC Power consumption CPU Units without Expansion I/O Units • ZEN-10C1AR-A-V2/ZEN-10C2AR-A-V2/ ZEN-10C3AR-A-V2 100 V AC max. 240 V AC: 7 ...

Page 8

Characteristics Item Control method Stored program control I/O control method Cyclic scan Programming language Ladder diagram Program capacity 96 lines (3 input conditions and 1 output per line) Max. No. of control I/O points 44 points (See note 1.) CPU ...

Page 9

Approved Standards Item Safety standards cULus: UL508/CSA C22.2 No.142 Class I Div2 Conforms to EN/IEC 61131-2 clause 11, excluding 11.7.2.2 (Overvoltage category 2 and Pollution degree II conforms to IEC 60664-1) EMC Radiation Field Emission (See note.) Noise Terminal Voltage ...

Page 10

DC Inputs: I4 and I5 for Units with 10 I/O points, Ia and Ib for Units with 20 I/O Points (Not Isolated) Item DC Inputs Input voltage VDC +20%, 10% Input impedance PNP: NPN: Input current PNP: ...

Page 11

Output Specifications (CPU Units and Expansion I/O Units) Units with Relay Outputs Item Maximum switching capacity 250 VAC/8 A (resistive load: cos = 1) 24 VDC/5 A (resistive load) Use the following values for the total of all outputs. CPU ...

Page 12

Connections Input Connections Units with AC Power Supply Note: 1. Supply power to both the CPU Unit and Expansion I/O Units from the same power supply and turn them ON and OFF at the same time. 2. The input circuit ...

Page 13

Units with DC Power Supply Note sure to connect the COM terminal before turning ON the power supply. If the COM terminal is disconnected the wiring is changed after turning ON the power supply, a malfunction ...

Page 14

CPU Units with 20 I/O Points For Connections to a Negative Common (PNP Connection VDC COM CPU Unit with 20 I/O points For Connecting Analog Input Devices to Input Terminals ...

Page 15

Output Connections Units with Relay Outputs All four relay output circuits in both CPU Units with 10 I/O points and Expansion I/O Units have independent contacts. CPU Units with 20 I/O points have 4 independent contacts (Q0 to Q3) and ...

Page 16

Nomenclature Standard LCD-type, Economy-type, and Communications-type CPU Units (Except for ZEN-@C2@@-@-V2 Models) CPU Units with 10 I/O Points Left side Power supply terminals Display screen Battery Unit connector (Remove the seal to connect the Battery Unit.) CPU Units with 20 ...

Page 17

... Function Menus Writing ladder program --- Deletes inputs, outputs, connection lines, and blank lines. --- • Switches between normally open and normally closed conditions. • Changes to connection line write mode. • Inserts a line. Moves the cursor • Moves the cursor up and down. up and down. ...

Page 18

LED-type CPU Units without Display (ZEN-@C2@@-@-V2) CPU Units with 10 I/O Points Left side Front Power supply terminals LED indicators Battery Unit connector (Remove the seal to connect ZEN Support Software connector the Battery Unit.) (also used for Memory Cassette.) ...

Page 19

Operation Bits Name Symbol Bit addresses Input bits (See note 2.) Expansion input bits Output bits (See note 2.) Expansion output bits Work bits ...

Page 20

Using Timers and Holding Timers X: ON-delay timer Trigger input Reset input Setting Present value 0 Timer bit : OFF-delay timer Trigger input Reset input Setting Present value 0 Timer bit O: One-shot pulse timer Trigger input Reset input ...

Page 21

Counter Operation Counter direction specification input Counter input Reset input Set value Present value 0000 Counter bit 5. 8-digit Counter Operation Count speed H High Counter direction speed specification input Counter input Reset input L Low Set value speed ...

Page 22

Example Calculation of Ladder Program Execution Time [ [ TT0 @ [Q2 6. Weekly Timer Operation (Only for Standard LCD-type, Economy-type, and Communications- type CPU Units) Weekly ...

Page 23

... When are selected, the ZEN switches to the display function screen if the display function is enabled and the specified data is displayed. The Main Screen will no longer be displayed. To display the Main Screen, change the CPU Unit to STOP mode. ...

Page 24

Specifications for Button Input Bits (Only for Standard LCD-type, Economy-type, and Communications-type CPU Units) The operation buttons are used to perform operations for input bits. They are useful when checking program operations or forcefully resetting holding timers or counters. ...

Page 25

ZEN Support Software Functions Note: Always use ZEN-SOFT01-V4 as the Support Software for the V2 CPU Unit. Creating Ladder Programs ZEN ladder programs can be created with ease. Note: The Edit Input Dialog Box is displayed when an input bit ...

Page 26

Dimensions Note: All units are in millimeters unless otherwise indicated. CPU Units CPU Units with 10 I/O Points ZEN-10C@@@-@- 4.7 (Sliding: 13 max.) CPU Units with 20 I/O Points ZEN-20C@@@-@- 4.7 (Sliding: 13 max.) Dimensions with ...

Page 27

... Expansion I/O Units ZEN-8E1 Power Supply Unit ZEN-PA03024 90 80 4.7 (Sliding: 13 max.) Accessories (Order Separately) Battery Unit ZEN-BAT01 DIN Track Hook (Using Slide) 7.6 Two, 3.5 dia 7 Memory Cassette ZEN-ME01 Programmable Relay Mounting Hole Dimensions 54 Two Mounting Hole Dimensions Two, M4 ...

Page 28

... Track Mounting Accessories (Order Separately) Mounting Track PFP-100N PFP-50N 4 1,000 (500 The numbers in parentheses () are dimensions for the PFP-50N. End Plate PFP pan-head screw 50 11 spring washer Precautions when Selecting ZEN Programmable Relays Changes in Comparison with Previous Models • The power supply and transistor output voltage ranges for CPU Units and Expansion I/O Units with DC power supply has been expanded to 10.8 to 28.8 VDC. • ...

Page 29

Precautions when Switching from Previous Units • Previous models of Expansion I/O Units cannot be connected to V2 CPU Units. • ZEN-8E1@R Expansion I/O Units with relay outputs need to be connected to a power supply. • A ZEN-@C@D@-D-V2 CPU ...

Page 30

Item DC inputs Input impedance 5 voltage 8 VDC min. (See note 2.) OFF voltage 3 VDC max. Analog inputs Input impedance 100 Accuracy 1.5% FS (at ambient operating ...

Page 31

Other Functions Item Bits Timer operation ON-delay, OFF-delay, one-shot pulse, flushing pulse, twin timer operation Weekly timer Timer operation, multiple-day operation, pulse- operation output operation Addition of bits 8-digit counter (1 counter 150 Hz) 8-digit comparators (4 comparators) ...

Page 32

Compatible Combinations of CPU Units and Expansion I/O Units The Expansion I/O Units that can be connected to V2 CPU Units are different from those that can be connected to V1 CPU Units and previous CPU Units. Expansion I/O Units ...

Page 33

... Restrictions Restrictions (See notes 2, 3, and 4.) (See note 4.) Support Software Ver. 1.0 Ver. 2.0 ZEN-SOFT01 ZEN-SOFT01- Restrictions (See note 2.) Not applicable. Not applicable. OMRON SYSMAC PLCs When the following instructions are executed, Q0 turns ON/OFF at the same time as the other bits cycle ...

Page 34

... For programming units and personal computers use only the connecting cable ZEN-CIF01 (optional accessory) manufactured by OMRON. ZEN-CIF01 provides safe (reinforced) insulation between personal computers and ZEN. • Provide emergency stop circuits, external interlock circuits, limit ...

Page 35

Precautions for Correct Use Installation Environment • Do not install the ZEN in the following locations. • Locations subject to radical changes in temperature • Locations with high humidity subject to condensation • Locations subject to excessive dust or dirt ...

Page 36

... Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority ...

Page 37

Cat. No. L106-E1-06rev 11/06 Specifications subject to change without notice Printed in USA ...