G12V42AH10EP EnerSys, G12V42AH10EP Datasheet

LEAD ACID BATTERY, 12V, 42AH

G12V42AH10EP

Manufacturer Part Number
G12V42AH10EP
Description
LEAD ACID BATTERY, 12V, 42AH
Manufacturer
EnerSys
Datasheet

Specifications of G12V42AH10EP

Battery Capacity
42Ah
Battery Voltage
12V
Battery Technology
Pure Lead
External Height
170.56mm
External Width
165.86mm
External Depth
197.49mm
Weight
32.9lb
Battery Terminals
Bolt
Height
6.72"
Lead Free Status / RoHS Status
na
TM
TM
GENESIS SELECTION GUIDE
FOURTH EDITION

Related parts for G12V42AH10EP

G12V42AH10EP Summary of contents

Page 1

GENESIS SELECTION GUIDE FOURTH EDITION TM TM ...

Page 2

... Global Headquart e rs EnerSys 14145 Reading Belgium PA 196212-4145 +32 (0)2 247 EnerS ys Asia + Guangdong, China +86-755-2689 3639 ...

Page 3

... GENESIS SELECTION GUIDE TABLE OF CONTENTS Company background EnerSys, Inc rvices and applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Features and benefits Technical information Capacity as a function of temperature State of charge Storage time as a function of temperature Voltage regulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GENESIS GENESIS product family ...

Page 4

... EnerSys’ environmentally progressive Warrensburg, Missouri plant, home base of the Genesis product lines, covers 320,000 square feet on 33 acres and employs more than 400 people. EnerSys was the first company in the United States to receive ISO 14001 certification. ISO 14001 focuses on the environmental management system of the business and provides a systematic approach to resource conserv ...

Page 5

... Batteries from EnerSys’ “pure lead-tin” family are used in a wide variety of standby and portable/cyclic applications including those in: • telecommunications • electronics • uninterruptible power supplies • defense installations • ...

Page 6

... This is 50% to 100% overall better performance for your energy dollar. 6 RUGGED CONSTRUCTION—Due to their strong external packaging and internal pure lead-tin composition, EnerSys’ products can withstand not only extreme temperatures but also harsh usage. THE PURE LEAD-TIN ...

Page 7

... The battery and outer pack- aging must be plainly and durably marked “NONSPILLABLE” or “NONSPILLABLE BAT T E RY”. GENESIS shipments from EnerSys Warrensburg location, will be properly labeled in accordance with applicable regulations. Packaging changes performed at other loca- ...

Page 8

C A PACITY AS A FUNCTION OF TEMPERATURE FOR GENESIS BAT TATE OF CHARGE FOR GENESIS BAT Certificate Number EMS 39520, ISO 14001 Certified Certificate Number FM ...

Page 9

GENESIS SELECTION GUIDE STORAGE TIME AS A FUNCTION OF TEMPERATURE FOR GENESIS BAT CHARGED BAT LTAGE REGULATION FOR GENESIS BAT ...

Page 10

... Most current waveforms are not pure DC nor are they pure sine waves. Therefore, consult the EnerSys Application Support Department for assistance when evaluating the charger current waveforms for your specific application. ...

Page 11

GENESIS SELECTION GUIDE GENESIS PRODUCT (All capacities at 10 hr. rate 25°C to 1.67 vpc) GENESIS EP : Internal res Part of fully charged ( ...

Page 12

... Terminal attachment torque for G13EP & G16EP—50 in. - lbs. (5.6 nm) Terminal attachment torque for G26EP & G42EP—60 in. - lbs. (6.8 nm) * Users planning to use CC should consult the EnerSys Application Support Department Caution: Batteries contain toxic materials (Pb and H Sealed-lead rechargeable battery must be recycled. Contact EnerSys Customer Service for details. ...

Page 13

GENESIS SELECTION GUIDE GENESIS EP MECHANICAL SPECIFICATIONS (A,B,& C — ...

Page 14

... Atmospheric pressure range—Vacuum to 2 atmospheres Terminal attachment torque for G70EP—60 in.-lbs. (6.8 nm) * Users planning to use CC should consult the EnerSys Application Support Department Caution: Batteries contain toxic materials (Pb and H Sealed-lead rechargeable battery must be recycled. Contact EnerSys Customer Service for details. ...

Page 15

GENESIS SELECTION GUIDE GENESIS 70EP MECHANICAL SPECIFICATIONS (A,B,& C — ...

Page 16

... Maximum recommended storage time before recharge—24 months @ 25°C or 2.0vpc, whichever is earlier Atmospheric pressure range—Vacuum to 2 atmospheres Terminal attachment torque—60 in. - lbs. (6.8 nm) * Users planning to use CC should consult the EnerSys Application Support Department Caution: Batteries contain toxic materials (Pb and H Sealed-lead rechargeable battery must be recycled. Contact EnerSys Customer Service for details. ...

Page 17

GENESIS SELECTION GUIDE GENESIS VP MECHANICAL SPECIFICATIONS (A,B,& C — ...

Page 18

GENESIS CONSTANT CURRENT (CC) DISCHARGE GENESIS CONSTANT POWER (CP) DISCHARGE Certificate Number EMS 39520, ISO 14001 Certified Certificate Number FM 32099, ISO 9001 Certified Publication No. US-GPL-SG-001 March 2003 GENESIS SELECTION GUIDE 16 ...

Page 19

... GENESIS SELECTION GUIDE ENERSYS STANDARD PRODUCT LIST GENESIS EP BAT G13EP (13Ah G13EPX (13Ah G16EP (16Ah G16EPX (16Ah G26EP (26Ah G26EPX (26Ah G42EP (42Ah G42EPX (42Ah G70EP (70Ah G70EPX (70Ah) GENESIS VP BAT G26VP (26Ah G26VPX (26Ah G42VP (42Ah G42VPX (42Ah PACITY RATINGS BASED ON END OF DISCHARGE VOLTAGE OF 1.67 VOLTS/CELL AT 25°C ...

Page 20

... TM Global Headquarters P.O. Box 14145 Reading, PA 196212-4145 TM USA Tel: +1-610-208-1991 +1-800-538-3627 www.enersysinc.com Fax: +1-610-372-8613 EnerSys EMEA Distributed by: Brussels, Belgium Tel: +32 (0)2 247 94 47 EnerSys Asia Guangdong, China Tel: +86-755-2689 3639 ...