PROTEXT-DIN RF Solutions, PROTEXT-DIN Datasheet

no-image

PROTEXT-DIN

Manufacturer Part Number
PROTEXT-DIN
Description
MOD, DIN, GSM REMOTE CONTROL SYSTEM
Manufacturer
RF Solutions
Datasheet

Specifications of PROTEXT-DIN

Svhc
No SVHC (15-Dec-2010)
Accessory Type
GSM Telemetry System
Power Supply Output Voltage @ Current
240VAC
Supply Voltage
24V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
DS PROTEXT-3 Mar 09
Applications
Ordering Information
Remote Control From a Mobile Phone
Easy to Install and Configure using SMS commands
(no PC required).
4 Digital Inputs (Volt Free)
User Can set inputs and outputs Names
Up to 5 mobiles per input
Outputs controlled by SMS text message
Request Status via SMS
Enclosure Rated IP68 (Pressure Washer Proof)
Automatically Sends SMS message when input
activated
Accepts all major SIM Cards
Remote control by GSM Mobile phone.
Remote Maintenance, warnings / Alarms.
Irrigation Systems.
Remote system monitoring.
Plant Maintenance.
Security Systems
Alert / Panic caller
Upto 8 Relay Outputs rated 240Vac 5A
PROTEXT-USA
PROTEXT-DIN
PROTEXT
PART No
©2009 REG No 277 4001, ENGLAND.
PROTEXT - GSM R
GSM Telemetry System IP68 Enclosure for use in N. America
GSM Telemetry System DIN Rail Module
GSM Telemetry System IP68 Enclosure
Description
EMOTE
Page 1
C
ONTROL
PROTEXT-DIN RAIL
PROTEXT
Inputs
PROTEXT
outputs

Related parts for PROTEXT-DIN

PROTEXT-DIN Summary of contents

Page 1

... PART No PROTEXT PROTEXT-DIN PROTEXT-USA DS PROTEXT-3 Mar 09 ©2009 REG No 277 4001, ENGLAND. EMOTE Description GSM Telemetry System IP68 Enclosure GSM Telemetry System DIN Rail Module GSM Telemetry System IP68 Enclosure for use in N. America C ONTROL PROTEXT PROTEXT-DIN RAIL PROTEXT outputs Inputs Page 1 ...

Page 2

... User Set-Up Commands .........................................................6 11. Control Commands .................................................................8 12. Messages generated by PROTEXT ......................................11 13. PROTEXT-DIN Optional Modules .........................................12 215 Relay Output Module............................................................................................................ 12 230 Relay Output Module............................................................................................................ 12 Enclosure / Mains Power Supply................................................................................................. 12 14. Technical Specifications ......................................................13 1. Definitions The following definitions are used throughout this document and generally in connection with the control unit ...

Page 3

... PROTEXT - GSM R 2. PROTEXT Features Integrated Antenna connector 2 x Relay outputs 3. PROTEXT DIN Features External Antenna connector via UFL connector 2 x Relay outputs on board 8 Outputs using Relay Module (These simply plug and play no additional connections required) SIM Card Here Power Connection ...

Page 4

... GND/IN2 GND/IN3 GND/IN4 These are volt-free digital inputs are designed to be actuated by contact ‘switch’ closures across the input pins. Two relay outputs are provided on PROTEXT and PROTEXT-DIN, which provide a ‘switch’ output as below. User Inputs Users Switch contacts PROTEXT-DIN can also provide a further six additional outputs by using the Relay Modules which connect directly to the PROTEXT-DIN ...

Page 5

... GSM activity, I.E. the unit is sending or receiving a text. 7. Power Loss In the event of power loss to the PROTEXT the unit will maintain the user configured data entered during the User set-up sequence, as this information is stored in non-volatile memory. However the status of the relays will be lost ...

Page 6

... Input number-to-text The number must be in full international format including country code and leading zeros. (INUM) Note the country code for the United Kingdom is 44. (Optional) Note the PROTEXT can store mobile number per input. DSPROTEXT-3 Mar 09 C EMOTE ONTROL Command Syntax UPW~< ...

Page 7

... Power Failure This command is used to identify the mobile number number-to-text which text if power has be removed from the (PNUM) PROTEXT. PNUM can store mobile numbers. (Optional) If either of INUMn or PNUM contain a mobile number that is already present in the phone number list then this Deleting numbers-to- number will be deleted ...

Page 8

... PROTEXT - GSM R 11. Control Commands PLEASE NOTE: ~ Denotes a ‘space’ in the format of a message Command Description Activate and deactivate outputs This command is used to turn a relay output on or off. (OUT) Retrieve status of This command requests that the status of the inputs inputs and outputs and outputs be returned to this caller ...

Page 9

... PROTEXT - GSM R Control Commands Cont… PLEASE NOTE: ~ Denotes a ‘space’ in the format of a message The <ISTRING> alphanumeric string consisting characters. Customising input names This string of characters sets the custom input (ISTRING) name. For example if input detector on a door then input 1 can be assigned the name DOOR. The < ...

Page 10

... PROTEXT - GSM R PLEASE NOTE: ~ Denotes a ‘space’ in the format of a message This command requests the mobile phone Retrieve saved numbers numbers for input (INUMn returned to text for INUMn to this caller. This command requests the mobile phone Retrieve saved numbers numbers to text in the event of power failure text for PNUM1 returned to this caller ...

Page 11

... A message is sent with the following Change Of Status Of format. Inputs A change of input will only be ‘valid’ after 5mSecs (IN) Where the PROTEXT unit is processing an SMS messages then the response time could 250mS. When an incoming SMS contains an error in the Error in received message format, no action will be taken by the unit ...

Page 12

... PROTEXT - GSM R 13. PROTEXT-DIN Optional Modules 215 Relay Output Module 8 relay switches rated 230Vac at 5A • Each relay provides ‘input’ and ‘normally open’ screw • terminals Dimensions: Within DIN Rail Storage Temperature: -10 to +70 Electrical Characteristics Supply Voltage Relay* output Rating ...

Page 13

... Technical Specifications Storage Temperature: PROTEXT Enclosure Rating PROTEXT Dimensions Electrical Characteristics Supply Voltage for 12Vdc Supply Voltage for 24Vdc Supply Current for PROTEXT: Idle Operating Mains rated Relay Rating (230Vac) Notes 1. Refers to maximum supply current required with all components idle. 2. Refers to peak supply current required with all components operating. In practice internal reservoir capacitance limits the instantaneous peak current to less than 500 mA ...