Specifications of GLK19264-7T-1U-WB-USB

Character Count X Line
32 x 8
Background Color
Blue
Voltage Rating
+ 5 VDC
Operating Temperature Range
- 20 C to + 70 C
Backlight Type
LED White
Interface
USB
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
GLK19264-7T-1U
Technical Manual
Revision: 1.2

Related parts for GLK19264-7T-1U-WB-USB

GLK19264-7T-1U-WB-USB Summary of contents

Page 1

... GLK19264-7T-1U Technical Manual Revision: 1.2 ...

Page 2

... Changing the I C Slave Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 4.5 Changing the Baud Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 4.6 Setting a Non-Standard Baud Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 5 Fonts 5.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 5.1.1 Font File Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 5.1.2 Creating a Font . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 5.2 Uploading a Font File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 5.3 Setting the Current Font . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 5.4 Font Metrics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Matrix Orbital GLK19264-7T- ...

Page 3

... Auto Transmit Key Presses 10.3 Auto Transmit Key Presses Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 10.4 Poll Key Press . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 10.5 Clear Key Buffer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 10.6 Set Debounce Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 10.7 Set Auto Repeat Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 10.8 Auto Repeat Mode Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 10.9 Assign Keypad Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Matrix Orbital GLK19264-7T- iii ...

Page 4

... Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 14.2 Read Version Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 14.3 Read Module Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 15 Command Summary 15.1 Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 15.2 Fonts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 15.3 Text . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 15.4 Bitmaps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 15.5 Bar Graphs and Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 15.6 General Purpose Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 15.7 Keypad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 15.8 Display Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 15.9 Filesystem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 15.10Data Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Matrix Orbital GLK19264-7T- ...

Page 5

... By Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 16 Appendix 16.1 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 16.1.1 Environmental . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 16.1.2 Electrical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 16.2 Optical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 16.3 Physical Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 16.4 Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 16.5 Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 16.6 Contacting Matrix Orbital . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 16.7 Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Matrix Orbital GLK19264-7T- ...

Page 6

... With the ability to communicate via serial RS-232/TTL and protocols, the versatile GLK19264-7T-1U can be used with virtually any controller. The GLK19264- 7T-1U-USB has the ability to communicate via USB. The ease of use of these displays is further enhanced by an intuitive command structure to allow display settings such as backlight brightness, contrast and baud rate to be software controlled ...

Page 7

... Figure 3: Standard Power Matrix Orbital Figure 4: 5V Power Adapter GLK19264-7T-1U 2 ...

Page 8

... Figure 5: 3ft Mini-B USB Cable Figure 7: Communication & Power Cable Matrix Orbital Figure 6: Breadboard Cable Figure 8: Serial Cable GLK19264-7T-1U 3 ...

Page 9

... Built in LED’s 1.4 Connecting The GLK19264-7T-1U Non-USB connects seamlessly and excellent means of testing the functionality and uploading new fonts and bitmaps. You will require a standard RS-232 9-pin serial cable such as the one pictured in Figure 8, as well as a modified 5V power adapter such as the one pictured in Figure 4 ...

Page 10

... MOGD# provides a new user friendly interface as well as many feature enhancements. To install MOGD# from the Matrix Orbital website, follow the following steps the website location: http://www.matrixorbital.ca/software/software_graphic/MOGDsharp/ 2. Click on “Download Here” Matrix Orbital GLK19264-7T-1U 5 ...

Page 11

... The serial port the display is plugged in to. Speed The communication speed the display module is set to. (Default 19,200) Display Type The type of display (GLK19264-7T-1U) PCB Revision The revision of the display you are using. (Found on the back of the PCB). Figure 10: Mogd Sharp Settings ...

Page 12

... Power Cable Standard Connector 2 Power/Data Connector 3 DB9 Connector Figure 11: GLK19264-7T-1U Non-USB 1 Power Cable Standard Connector 2 USB mini-B Connector 3 Protocol Select Jumpers NOTE * The USB module can have a header populated at your request to allow for an internal USB cable, talk to a Sales representitive for details. ...

Page 13

... DB-9 Connector - For Non-USB modules only The GLK19264-7T-1U provides a DB-9 Connector to readily interface with serial devices which use the EIA232 standard signal levels of ±30V also possible to communicate at TTL levels +5V by setting the Protocol Select Jumpers to TTL added feature it is also possible to apply power through pin 9 of the DB-9 Connector in order to reduce cable clutter ...

Page 14

... AND through the Power/Data Connector at the same time. 2.2 Power/Data Connector for Non-USB modules only The Power/Data Connector provides a standard connector for powering the display module. The GLK19264- 7T-1U requires five volts for the standard display module. The voltage is applied through pins one and four of the four pin Power/Data connector ...

Page 15

... Non-USB module. For the USB module operation the USB jumpers must be in place. There are three, one is for power. If you wish to power it up from a non-USB source, you must remove one of the jumpers. The jumper to remove is the rightmost USB jumper as seen if Figure 18. Figure 17: Protocol-Select-Jumpers for GLK19264-7T-1U Non-USB Matrix Orbital Figure 16: Serial Header 2 C protocols ...

Page 16

... Figure 18: Protocol-Select-Jumpers for GLK19264-7T-1U USB 2.5 Manual Override The Manual Override is provided to allow the GLK19264-7T- reset to some of the factory defaults. This can be particularly helpful if the display module has been set to an unknown baud rate or I slave address and you are no longer able to communicate with it. If you wish to return the module to its default settings you must press the bottom left button at power up. Please see fi ...

Page 17

... The last step will be to check the Power / Data Connector on the GLK19264-7T-1U. If the Power / Data Connector has become loose, or you are unable to resolve the issue, please contact Matrix Orbital see 16 ...

Page 18

... There is a problem uploading fonts or bitmaps. • First, ensure that you can communicate to the display. A good test is to use a PC, with MOGD# installed, to connect to the display. See Section 1.4 on page 4for setting test the GLK19264- 7T-1U. • Second, ensure that the Filesystem Lock Jumper has not been jumpered. See Section 2.6 on the previous page. • ...

Page 19

... The default read address of the display module will be 0x51, whereas the write address is 0x50 by default. This address may be changed by using cmd 254 / 51 / <address>. The GLK19264-7T-1U should only be sent addresses that are even (LSB ...

Page 20

... Protocol Select Jumpers to TTL. 4.1.4 USB Communication The GLK19264-7T- USB device that offers identical communication protocol as the serial com- port. capable of communicating via a USB interface. The USB communications are identical to the serial communications. Communication is via a virtual com port, which is created in the operating system by the drivers necessary to install the USB display ...

Page 21

... Off 4.3 Turn Flow Control Off Matrix Orbital 0xFE 0x3A [full] [empty] 254 58 [full] [empty] 254 “:” [full] [empty] Length Description 1 Bytes remaining before issuing a almost full message. (Full Bytes available before issuing a almost empty message. (Empty is 128 mode. GLK19264-7T-1U 16 ...

Page 22

... The new I C write address (0x00 - 0xFF write address of the module between 0x00 2 C write address must be an even number and the read 0xFE 0x39 [speed] 254 57 [speed] 254 “9” [speed] Length Description 1 Hex value corresponding to a baud rate. GLK19264-7T- write 17 ...

Page 23

... Manual Override jumper to be set. Remembered Always Matrix Orbital Baud Rate 9600 14400 19200 28800 38400 57600 76800 115200 0xFE 0xA4 [speed] 254 164 [speed] Length Description 2 Inputed LSB MSB from baud rate formula (12-2047). GLK19264-7T-1U CrystalSpeed 1 to 8×DesiredBaud 18 ...

Page 24

... Fonts 5.1 Introduction The GLK19264-7T-1U comes loaded with the ’Small Filled’ and ’Futura Bk BT 16’ fonts by default. However capable of displaying any font that is uploaded the correct format. MOGD# provides a simple method of generating font files from your installed fonts. For instructions on how to install MOGD# see Section 1 ...

Page 25

... Matrix Orbital Figure 21: Bitmaps for h, i, and j Table 8: Font File Header Height ASCII Start Val 0x07 0x68 Bitmap Data Byte 10000100 00101101 10011000 11000110 00100000 Figure 22: Bitmap Encoding GLK19264-7T-1U ASCII End Val 0x6A Hex Value 0x84 0x2D 0x98 0xC6 0x20 20 ...

Page 26

... Table 9: Character Table Low Offset (LSB) Character Width 0x0D 0x12 0x15 Table 10: Sample Font File 0x68 0x6A 0x00 0x0D 0x05 0x00 0x15 0x04 0x84 0x2D 0x43 0x24 0x84 0x2D 0x98 GLK19264-7T-1U 0x05 0x03 0x04 0x05 0x03 0x04 0x00 0x98 0x19 21 ...

Page 27

... Description In order to upload a font to the GLK19264-7T-1U you must first initiate the upload font file command (0xFE 0x24), you must then pass it a reference identification number, which must be unique for every font on the display module. You may then pass the display module the two byte fi ...

Page 28

... GLK19264-7T-1U. It defines the row that, when filled, will cause the display to auto scroll if auto scrolling is enabled. The font metrics will have to be reconfi ...

Page 29

... Character Set The graphic displays such as the GLK19264-7T-1U, do not have built in character sets. Instead fonts are uploaded to the display using the commands detailed in Section 5 on page 19. 6.1.2 Control Characters ...

Page 30

... Section 5.4 on page 23. Remembered Yes Default On 6.6 Auto Scroll Off Matrix Orbital Length Description 1 Column 1 Row 0xFE 0x79 [x] [y] 254 121 [x] [y] 254 “y” [x] [y] Length Description 1 The horizontal position in pixels. 1 The vertical position in pixels. 0xFE 0x51 254 81 254 “Q” GLK19264-7T-1U 25 ...

Page 31

... Bitmaps 7.1 Introduction One of the main features of the GLK19264-7T-1U is its ability to display bitmap images, that are either loaded onto its on board memory, or written directly to the screen. This chapter will cover creating a bitmap, uploading the bitmap, as well as drawing the bitmap from memory and directly. ...

Page 32

... Description The GLK19264-7T-1U is capable of storing 128 font and bitmap files Kbytes total. In order to upload a bitmap to the GLK19264-7T-1U you must first initiate the upload font file command (0xFE 0x5E), you must then pass it a reference identification number, which must be unique for every font on the display module. You may then pass the display module the two byte fi ...

Page 33

... Bar Graphs and Drawing 8.1 Introduction Supplementary to the ability of the GLK19264-7T-1U to display bitmaps and fonts, the GLK19264-7T- 1U also allows for a robust 2D drawing environment. With the ability to draw by pixel, line or rectangle, as well as the ability to continue a line to form a polygon, we are certain that you will spend less time, developing and creating better looking projects. With the addition of custom bar and strip graphs, you are sure to fi ...

Page 34

... Length Description 1 X screen location screen location. 0xFE 0x6C [x1] [y1] [x2] [y2] 254 108 [x1] [y1] [x2] [y2] 254 “l” [x1] [y1] [x2] [y2] Length Description 1 Left bounds. 1 Top Bounds. 1 Right Bounds. 1 Bottom Bounds. GLK19264-7T-1U 29 ...

Page 35

... Black). 1 Left bounds. 1 Top Bounds. 1 Right Bounds. 1 Bottom Bounds. 0xFE 0x78 [color] [x1] [y1] [x2] [y2] 254 120 [color] [x1] [y1] [x2] [y2] 254 “x” [color] [x1] [y1] [x2] [y2] Length Description 1 Drawing color (0: White, 1-255: Black). 1 Left bounds. 1 Top Bounds. 1 Right Bounds. 1 Bottom Bounds. GLK19264-7T-1U 30 ...

Page 36

... Length Description 1 Reference number 1 Type of bar graph. 1 Left bounds. 1 Top Bounds. 1 Right Bounds. 1 Bottom Bounds. Direction Bar Start Point Vertical Bottom Horizontal Left Vertical Top Horizontal Right GLK19264-7T-1U 31 ...

Page 37

... Length Description 1 Initialized bar graph reference number. 1 The number of pixels to fill. 0xFE 0x6A [refID] [x1] [y1] [x2] [y2] 254 106 [refID] [x1] [y1] [x2] [y2] 254 “j” [refID] [x1] [y1] [x2] [y2] Length Description 1 Reference number 1 Left bounds. 1 Top Bounds. 1 Right Bounds. 1 Bottom Bounds. GLK19264-7T-1U 32 ...

Page 38

... This restriction does not apply to y values. Remembered No 8.11 Shifting a Strip Chart Hexadecimal Syntax Decimal ASCII Parameters Parameter ref Matrix Orbital 0xFE 0x6B [ref] 254 107 [ref] 254 “k” [ref] Length Description 1 Reference number of a strip chart that has already been created. GLK19264-7T-1U 33 ...

Page 39

... General Purpose Output 9.1 Introduction The GLK19264-7T-1U has 6 General purpose outputs which are connected to 3 tri-colour LEDs. The LEDs consist of red, green and orange-yellow colours. The LEDs are hence software controlled with func- tions to turn them on/off. A pair of GPOs control one LED. GPO1 and GPO2 control LED1, GPO3 and GPO4 control LED2 and GPO5 and GPO6 control LED3. The tables below illustrate the relation. “ ...

Page 40

... Table 34: LED 2 - middle GPO4 GPO3 Yellow 0 0 Green 0 1 Red 1 0 Off 1 1 Table 35: LED 3 - bottom GPO6 GPO5 Yellow 0 0 Green 0 1 Red 1 0 Off 1 1 0xFE 0x56 [Num] 254 86 [Num] 254 “V” [Num] Length Description 1 GPO number. GLK19264-7T-1U 35 ...

Page 41

... Always 10 Keypad 10.1 Introduction The GLK19264-7T-1Usupports Key, matrix style, embedded keypad and may be configured to allow key presses to be automatically transmitted via RS-232 or polled through I 1U also allows for auto-repeating key presses. The keypad is scanned whenever a key is pressed;there is no continuous key scan. This means that key presses are dealt with immediately without any appreciable latency ...

Page 42

... Remembered Yes Matrix Orbital Table 39: Keypad Values up arrow 0x42 down arrow 0x48 left arrow 0x44 right arrow 0x43 center 0x45 top left 0x41 bottom left 0x47 0xFE 0x41 254 65 254 “A” 0xFE 0x4F 254 79 254 “O” GLK19264-7T-1U 37 ...

Page 43

... Set Debounce Time Hexadecimal Syntax Decimal ASCII Parameter Parameters time Matrix Orbital 0xFE 0x26 254 38 254 “&” 0xFE 0x45 254 69 254 “E” 0xFE 0x55 [time] 254 85 [time] 254 “U” [time] Length Description 1 Debounce time in increments of 6.554ms (0 - 255). GLK19264-7T-1U 38 ...

Page 44

... In this mode, when a key is held down, the key code is transmitted immediately and no other codes will be sent until the key is released. On the release of the key, the key release code transmitted will be a value equal to the key down code plus 20 hex. GLK19264-7T-1U 39 ...

Page 45

... This command turns auto repeat mode off. See Set Auto Repeat Mode. Remembered No 10.9 Assign Keypad Codes Hexadecimal Syntax Decimal Parameters Parameter KDown KUp Matrix Orbital 0xFE 0x60 254 96 254 “‘” 0xFE 0xD5 [KDown] [KUp] 254 213 [KDown] [KUp] Length Description 9 Key down codes 9 Key up codes GLK19264-7T- the “Key 40 ...

Page 46

... Display Functions 11.1 Introduction The GLK19264-7T-1U employs software controlled display settings, which allow for control over, clear- ing the screen, changing the brightness and contrast or setting timers for turning off. The combination of these allow you complete software control over your display’s appearance. ...

Page 47

... Length Description 1 Minutes before turning the display 90). 0xFE 0x46 254 70 254 “F” 0xFE 0x99 [brightness] 254 153 [brightness] Length Description 1 Display brightness setting (0 to 255). GLK19264-7T-1U 42 ...

Page 48

... Matrix Orbital 0xFE 0x98 [brightness] 254 152 [brightness] Length Description 1 Backlight setting (0 to 255). 0xFE 0x50 [contrast] 254 80 [contrast] 254 “P” [contrast] Length Description 1 Contrast value (0 to 255). This command has only 32 levels for X-Board based displays, meaning eight GLK19264-7T-1U 43 ...

Page 49

... Filesystem 12.1 Introduction The GLK19264-7T-1U incorporates a 16 Kbyte on board flash memory in order to allow up to 128 font and bitmap files to be transfered directly onto the display and recalled whenever necessary. The filesystem can address font and bitmap files combined Kbytes recommended that fonts and bitmaps are uploaded when possible all together after a fi ...

Page 50

... Font ASCII Start Value 0x49 Echo Font ASCII Start Value Confimation Byte ... ... Last Font File Byte 0x60 Echo Last Font File Byte Confirm Upload Finished Table 55: Upload Protocol Description Confirm: Will continue the file transfer. Decline: Terminate the session. GLK19264-7T-1U 45 ...

Page 51

... NOTES • The GLK19264-7T-1U has watch dog timer, set to 2.1 seconds in between transmis- sions, in order prevent the display module from staying in a waiting state. • Once the timeout has been reached the timer will reset the display and issue a 0xFE 0xD4 response to the host to signal that this has happened. ...

Page 52

... ACK (NAK if CRCs don’t match) Block Count 255 - Block Count 0x06 ACK (NAKif counts don’t match) Data Block CRC High Byte CRC Low Byte 0x06 ACK (NAKif CRCs don’t match) ... ... End of Transmission 0x06 ACK (NAK if EOT is not expected) Table 56: XModem Upload Protocol GLK19264-7T-1U 47 ...

Page 53

... Parameters type refID Description This command erases a single fi time within the GLK19264-7T-1U memory when given two parameters: [type] and [refID]. The file type and reference number are defined when the file is saved to the GLK19264-7T-1U. • [type Bitmap • [type Font NOTE After deleting a fi ...

Page 54

... FileID/Type: 1st bit is the file type (0: Font, 1: Bitmap). Next 7 bits are the file ID. File Size: LSB File Size: MSB 0xFE 0xB0 [Size] [Data] 254 176 [Size] [Data] Length Description 4 LSB to MSB filesystem image data var Actual data to upload GLK19264-7T-1U 49 ...

Page 55

... Ensuring that your GLK19264-7T-1U display’s exactly what you want it to can be the difference between a projects success and failure. This is why we incorporate features such as Data Lock into the GLK19264- 7T-1U With this new feature you now are in control over of how and when settings will be changed so there is no need to worry about the module acting exactly like you expected it to because all the settings may be locked and remembered for the next power up ...

Page 56

... Do not remember 13.3 Data Lock Hexadecimal Syntax Decimal Parameters Parameter level Matrix Orbital 0xFE 0x93 [switch] 254 147 [switch] Length Description not remember, 1: Remember 0xFE 0xCA 0xF5 0xA0 [level] 254 202 245 160 [level] Length Description 1 Sets the data lock level GLK19264-7T-1U 51 ...

Page 57

... Display Lock When this bit is set (1) the module is locked from dis- playing any new informa- tion. (text lock) Hex Dec Binary 0x00 0 0 0x50 80 01010000 Setting and Command Lock GLK19264-7T- Slave Description Unlock 52 ...

Page 58

... Length Description 1 Sets the data lock level 0xFE 0x30 254 48 254 “0” 0xFE 0x34 [data] 254 52 [data] 254 “4” [data] Length Description 16 Writes the customer data 0xFE 0x35 254 53 254 “5” GLK19264-7T-1U 53 ...

Page 59

... This command will return a byte representing the version of the module, see the following table as an example: Remembered No 14.3 Read Module Type Hexadecimal Syntax Decimal ASCII Matrix Orbital 0xFE 0x36 254 54 254 “6” Hex Value Version Number 0x19 Version 1.9 0x57 Version 5.7 0xFE 0x37 254 55 254 “7” GLK19264-7T-1U 54 ...

Page 60

... LK404-25 74 Unused 78 GLT480282 7A GLK19264-7T-1U Product ID LCD2021 LCD4021 LK202-25 LK404-55 VFD2041 VK202-25 GLC12232 Unused Unused GLK12232-25 GLK12232-25-SM GLK24064-16-1U GLK12232-16 GLK19264-7T-1U LK204-7T-1U-USB MOS-AV-162A LK162-12 LK202-24-USB LK204-24-USB PK162-12 MOS-AP-162A MOS-AL-162A MOS-AV-202A PK202-24-USB MOS-AL-204 MOS-AL-402 LK082-12 VK404-55 VK402-25 Unused MOI XBoard-I XBoard-U VK202-25-USB VK204-25-USB Unused ...

Page 61

... Decimal 254 50 [lm] [tm] [csp] [lsp] [srow] ASCII 254 “2” [lm] [tm] [csp] [lsp] [srow] Hexadecimal 0xFE 0xAC [value] Decimal 254 172 [value] Syntax Hexadecimal 0xFE 0x48 Decimal 254 72 ASCII 254 “H” GLK19264-7T-1U Page Page Page 24 56 ...

Page 62

... ASCII 254 “p” [x] [y] Hexadecimal 0xFE 0x6C [x1] [y1] [x2] [y2] Decimal 254 108 [x1] [y1] [x2] [y2] ASCII 254 “l” [x1] [y1] [x2] [y2] Hexadecimal 0xFE 0x65 [x] [y] Decimal 254 101 [x] [y] ASCII 254 “e” [x] [y] GLK19264-7T-1U Page Page Page ...

Page 63

... Decimal 254 195 [Num] [state] Syntax Hexadecimal 0xFE 0x41 Decimal 254 65 ASCII 254 “A” Hexadecimal 0xFE 0x4F Decimal 254 79 ASCII 254 “O” Hexadecimal 0xFE 0x26 Decimal 254 38 ASCII 254 “&” GLK19264-7T-1U Page Page Page ...

Page 64

... Hexadecimal 0xFE 0x50 [contrast] Decimal 254 80 [contrast] ASCII 254 “P” [contrast] Hexadecimal 0xFE 0x91 [contrast] Decimal 254 145 [contrast] Syntax Hexadecimal 0xFE 0x21 0x59 0x21 Decimal 254 ASCII 254 “!” “Y” “!” GLK19264-7T-1U Page Page Page 46 59 ...

Page 65

... Decimal 254 52 [data] ASCII 254 “4” [data] Hexadecimal 0xFE 0x35 Decimal 254 53 ASCII 254 “5” Syntax Hexadecimal 0xFE 0x36 Decimal 254 54 ASCII 254 “6” Hexadecimal 0xFE 0x37 Decimal 254 55 ASCII 254 “7” GLK19264-7T-1U Page Page Page ...

Page 66

... Drawing a Bitmap Directly “e” Continue a Line “g” Initializing a Bar Graph “i” Drawing a Bar Graph “j” Initializing a Strip Chart “k” Shifting a Strip Chart “l” Drawing a Line “p” Draw Pixel “r” Draw a Rectangle GLK19264-7T- ...

Page 67

... Moving a File Set Startup GPO state Data Lock Table 84: Environmental Specifications Standard Temperature ◦ ◦ +50 C ◦ ◦ - +70 C 90% max non-condensing 2 4.9 m/s XYZ directions 2 19.6 m/s 2 29.4 m/s 2 490 m/s XYZ directions GLK19264-7T- Extended Temperature ◦ ◦ - +70 C ◦ ◦ ...

Page 68

... Table 86: Optical Characteristics 192 x 64 pixels 256 (maximum 32 characters x 8 Lines with 5x7 font 28.4mm 0.36 x 0.36mm 0.39 x 0.39mm 20,000 hours typical 10,000 hours typical White or Green LED GLK19264-7T-1U -LV 63 ...

Page 69

... NOTE Autocad version is downloadable from the Matrix Orbital Manual download lo- cation. Matrix Orbital Figure 24: Physical Diagram GLK19264-7T-1U 64 ...

Page 70

... Pixel Width Count 64: Pixel Height Count -7T: Seven Integrated Tactile Keys -1U: Fits a 1U Opening NP: Standard RS232/TTL/I -USB: Universal Serial Bus Only -YG: Grey/Yellow-Green -GW: Grey/White -WB: White/Blue NP: Standard (4.75-5.25V) -LV: Low Voltage (3.30V) ◦ NP: Standard ( +50 -E: Extended Temperature (-20 Table 88: Part Options GLK19264-7T- ◦ C) ◦ ◦ + ...

Page 71

... Sales: 1(403)229-2737 Support: 1(403)204-3750 On The Web Sales: http://www.MatrixOrbital.com Support: http://www.MatrixOrbital.ca Forums: http://www.lcdforums.com 16.7 Revision History Revision Number 1.0 1.1 1.2 Matrix Orbital Table 89: Revision History Description Initial Manual -LV Option Added Updated Backlight Life GLK19264-7T-1U Author Clark Clark Clark 66 ...

Related keywords