Fuses C518 2A BUSS FA BK 100 BOX-R

BK-C518-2-R

Manufacturer Part NumberBK-C518-2-R
DescriptionFuses C518 2A BUSS FA BK 100 BOX-R
ManufacturerCooper/Bussmann
TypeMiniature
SeriesC518
BK-C518-2-R datasheet
 

Specifications of BK-C518-2-R

ActingFastVoltage Rating (vac)250V
Current Rating2AMountingThrough Hole
Product Depth (mm)Not RequiredmmProduct Height (mm)Not Requiredmm
Housing MaterialGlassVoltage Rating250 Volts
Fuse Size / Group5 mm x 15 mmTermination StyleAxial
Fuse TypeFast ActingBody MaterialGlass
Dimensions15.2 mm L x 5.5 mm DProductAxial Lead and Cartridge Fuses
Interrupt Rating100 AmpsMounting StyleThrough Hole
Resistance0.064 OhmsLead Free Status / RoHS StatusCompliant
1
Page 1
2
Page 2
Page 1/2

Download datasheet (229Kb)Embed
Next
5 x 15mm Fast-Acting Glass Tube Fuses
C518 Series
Description
• Axial-leaded fast-acting
• 5 x 15mm physical size
• Nickel-plated brass endcap construction
• Optional insulation sleeve is flexible flouropolymer
(UL Flammability rating VW-1).
• UL Listed product meets standard UL 248-14
Electrical Characteristics
Rated Current
Amp Rating
100%
100mA-5A
135%
200%
Agency Information
• UL Recognition Card: Guide JDYX2, File E19180
• CSA Certification Card: Class 1422-01, File 53787
Ordering
Specify product code
• Insert packaging code prefix before part number. E.g.
BK (or TR2)/C518-2-R
Specify option code, if desired
• For insulation sleeve, insert “S” after part series. E.g.
BK/C518S-2-R
Voltage
Part Number
Rating
Vac
C518-100-R
250
C518-125-R
250
C518-250-R
250
C518-375-R
250
C518-500-R
250
C518-750-R
250
C518-1.5-R
250
C518-2-R
250
C518-2.5-R
250
C518-3-R
250
C518-3.5-R
250
C518-4-R
250
C518-5-R
250
* DC Cold Resistance (Measured at <10% of rated current)
** Typical Melting I
2
t (A
2
Sec) (Minimum at 10 times rated current)
*** Typical Voltage Drop (Voltage drop was measured at 20°C ambient temperature at rated current)
0909
BU-SB09718
Opening Time
None
Dimensions - mm
60 minutes max.
Drawing Not to Scale
2 seconds max.
• With TR2 packaging code, lead wire length is 20.3mm
Specifications
Interrupting Rating
Typical DC Cold
at Rated Voltage (amps)
Resistance*
250Vac
125Vac
35
10,000
22.30
35
10,000
15.20
35
10,000
35
10,000
35
10,000
35
10,000
100
10,000
0.900
100
10,000
0.064
100
10,000
0.046
100
10,000
0.038
100
10,000
0.032
200
10,000
0.022
200
10,000
0.018
Page 1 of 2
Typical
Melting I
2
t**
Voltage
(Ω Ω )
AC
Drop (mV)***
0.0010
0.0019
5.66
0.012
2.53
0.039
1.66
0.059
0.91
0.264
0.800
1.9
2.9
6.1
9.7
16.6
22.4
Data Sheet 2026
Max
2230
1930
1450
968
845
686
135
136
121
116
115
88
91

BK-C518-2-R Summary of contents

  • Page 1

    ... CSA Certification Card: Class 1422-01, File 53787 Ordering Specify product code • Insert packaging code prefix before part number. E.g. BK (or TR2)/C518-2-R Specify option code, if desired • For insulation sleeve, insert “S” after part series. E.g. BK/C518S-2-R Voltage ...

  • Page 2

    ... Packaging Code Prefix Description BK 100 fuses packed into a cardboard carton TR2 1,500 fuses packed into tape on a reel (20.3mm lead wire length) Option Code Description S Insulation Sleeve The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications ...