B84111AK10 EPCOS Inc, B84111AK10 Datasheet

Power Line Filters 1A 115/250V 2-LINE

B84111AK10

Manufacturer Part Number
B84111AK10
Description
Power Line Filters 1A 115/250V 2-LINE
Manufacturer
EPCOS Inc
Datasheets

Specifications of B84111AK10

Operating Frequency
50 to 60Hz
Current Rating (max)
1A
Voltage Rating Max
250VAC
Termination
Quick Connect
Mounting Style
Flange
Product Depth (mm)
32mm
Voltage Rating
250 VAC / 250 VDC
Current Rating
1 A
Termination Style
IEC Connector on line side, Tab Connector on load side
Lead Free Status / RoHS Status
Compliant
EMC filters
2-line filters
SIFI-A for normal insertion loss
Rated current 1 to 20 A
Series/Type:
B84111A
Date:
January 2006
 EPCOS AG 2006. Reproduction, publication and dissemination of this data sheet and the
information contained therein without EPCOS’ prior express consent is prohibited.

Related parts for B84111AK10

B84111AK10 Summary of contents

Page 1

EMC filters 2-line filters SIFI-A for normal insertion loss Rated current Series/Type: B84111A Date: January 2006  EPCOS AG 2006. Reproduction, publication and dissemination of this data sheet and the information contained therein without EPCOS’ prior ...

Page 2

SIFI-A for normal insertion loss Power line filters for 1-phase systems Rated voltage 250 V DC/AC, 50/60 Hz Rated current Alternative version ■ Series B84111F (SIFI-F) offers a low-cost solution Construction ■ 2-line filters ...

Page 3

SIFI-A for normal insertion loss Circuit diagram LINE L N Technical data and measuring conditions Rated voltage V R Rated current I R Test voltage V test Leakage current l leak Climatic category (IEC 60068-1) Approvals Please read ...

Page 4

SIFI-A for normal insertion loss Characteristics and ordering codes 250 V DC/AC, 50/ × 0.1 µF (X2) 2 × 1.5 2 × 4700 ...

Page 5

SIFI-A for normal insertion loss Case styles and dimensions Case I Dimensions (mm) R style 26 — 26.5 60 26.5 ...

Page 6

SIFI-A for normal insertion loss Case style B 6 and 10 A (B84111A0000B060, B110 Tab connector A6.3 x 0.8 ø4.7 SSB0528-L-E Case style Tab connector A6.3 x 0.8 Panel ...

Page 7

SIFI-A for normal insertion loss Insertion loss (typical values Ω) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) Filters for 100 B84111A0000*010 dB B84111A0000*020 ...

Page 8

EMC filters Cautions and warnings Important information Please read all safety and warning notes carefully before installing the EMC filter and putting it into operation (see ). The same applies to the warning signs on the filter. Please ensure that ...

Page 9

EMC filters Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge ...