SIOV-S14K17G5S5 EPCOS Inc, SIOV-S14K17G5S5 Datasheet

no-image

SIOV-S14K17G5S5

Manufacturer Part Number
SIOV-S14K17G5S5
Description
Manufacturer
EPCOS Inc
Datasheet

Specifications of SIOV-S14K17G5S5

Technology
Metal Oxide
Capacitance Value
8200pF
Clamping Current
10A
Clamping Voltage
53V
Lead Style
Radial
Ac Voltage Rating (max)
17VAC
Dc Voltage Rating (max)
22VDC
Operating Temp Range
-40C to 85C
Mounting
Through Hole
Surge Current (max)
1000A
Lead Spacing
7.5mm
Product Depth (mm)
4.4mm
Product Height (mm)
18.5mm
Product Diameter (mm)
15.5mm
Varistor Voltage
27V
Lead Free Status / RoHS Status
Compliant
SIOV metal oxide varistors
Leaded varistors, StandarD series
Series/Type:
S05, S07, S10, S14, S20
Date:
December 2007
Data Sheet
Data Sheet
 EPCOS AG 2008. Reproduction, publication and dissemination of this publication, enclosures
hereto and the information contained therein without EPCOS’ prior express consent is prohibited.

Related parts for SIOV-S14K17G5S5

SIOV-S14K17G5S5 Summary of contents

Page 1

... SIOV metal oxide varistors Leaded varistors, StandarD series Series/Type: S05, S07, S10, S14, S20 Date: December 2007 Data Sheet Data Sheet  EPCOS AG 2008. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS’ prior express consent is prohibited. ...

Page 2

Leaded varistors StandarD series Construction ■ Round varistor element, leaded ■ Coating: epoxy resin, flame-retardant V-0 ■ Terminals: tinned copper wire Features ■ Wide operating voltage range 11 … 1100 V ■ High surge current ratings up ...

Page 3

... Maximum ratings (T A Ordering code Type (untaped) SIOV- B72205S0110K101 S05K11 B72207S0110K101 S07K11 B72210S0110K101 S10K11 B72214S0110K101 S14K11 B72220S0110K101 S20K11 B72205S0140K101 S05K14 B72207S0140K101 S07K14 B72210S0140K101 S10K14 B72214S0140K101 S14K14 B72220S0140K101 S20K14 B72205S0170K101 S05K17 B72207S0170K101 S07K17 B72210S0170K101 S10K17 B72214S0170K101 S14K17 B72220S0170K101 S20K17 B72205S0200K101 ...

Page 4

Leaded varistors StandarD series = 25 °C) Characteristics (T A Ordering code mA) V B72205S0110K101 18 B72207S0110K101 18 B72210S0110K101 18 B72214S0110K101 18 B72220S0110K101 18 B72205S0140K101 22 B72207S0140K101 22 B72210S0140K101 22 B72214S0140K101 22 B72220S0140K101 22 B72205S0170K101 27 B72207S0170K101 ...

Page 5

... Maximum ratings (T A Ordering code Type (untaped) SIOV- B72205S0350K101 S05K35 B72207S0350K101 S07K35 B72210S0350K101 S10K35 B72214S0350K101 S14K35 B72220S0350K101 S20K35 B72205S0400K101 S05K40 B72207S0400K101 S07K40 B72210S0400K101 S10K40 B72214S0400K101 S14K40 B72220S0400K101 S20K40 B72205S0500K101 S05K50 B72207S0500K101 S07K50 B72210S0500K101 S10K50 B72214S0500K101 S14K50 B72220S0500K101 S20K50 B72205S0600K101 ...

Page 6

Leaded varistors StandarD series = 25 °C) Characteristics (T A Ordering code mA) V B72205S0350K101 56 B72207S0350K101 56 B72210S0350K101 56 B72214S0350K101 56 B72220S0350K101 56 B72205S0400K101 68 B72207S0400K101 68 B72210S0400K101 68 B72214S0400K101 68 B72220S0400K101 68 B72205S0500K101 82 B72207S0500K101 ...

Page 7

... Maximum ratings (T A Ordering code Type (untaped) SIOV- B72205S0111K101 S05K115 B72207S0111K101 S07K115 B72210S0111K101 S10K115 B72214S0111K101 S14K115 B72220S0111K101 S20K115 B72205S0131K101 S05K130 B72207S0131K101 S07K130 B72210S0131K101 S10K130 B72214S0131K101 S14K130 B72220S0131K101 S20K130 B72205S0141K101 S05K140 B72207S0141K101 S07K140 B72210S0141K101 S10K140 B72214S0141K101 S14K140 B72220S0141K101 S20K140 B72205S0151K101 ...

Page 8

Leaded varistors StandarD series = 25 °C) Characteristics (T A Ordering code mA) V B72205S0111K101 180 B72207S0111K101 180 B72210S0111K101 180 B72214S0111K101 180 B72220S0111K101 180 B72205S0131K101 205 B72207S0131K101 205 B72210S0131K101 205 B72214S0131K101 205 B72220S0131K101 205 B72205S0141K101 220 B72207S0141K101 ...

Page 9

... Maximum ratings (T A Ordering code Type (untaped) SIOV- B72205S0271K101 S05K275 B72207S0271K101 S07K275 B72210S0271K101 S10K275 B72214S0271K101 S14K275 B72220S0271K101 S20K275 B72205S0301K101 S05K300 B72207S0301K101 S07K300 B72210S0301K101 S10K300 B72214S0301K101 S14K300 B72220S0301K101 S20K300 B72210S0321K101 S10K320 B72214S0321K101 S14K320 B72220S0321K101 S20K320 B72205S0381K101 S05K385 B72207S0381K101 S07K385 B72210S0381K101 ...

Page 10

Leaded varistors StandarD series = 25 °C) Characteristics (T A Ordering code mA) V B72205S0271K101 430 B72207S0271K101 430 B72210S0271K101 430 B72214S0271K101 430 B72220S0271K101 430 B72205S0301K101 470 B72207S0301K101 470 B72210S0301K101 470 B72214S0301K101 470 B72220S0301K101 470 B72210S0321K101 510 B72214S0321K101 ...

Page 11

... Maximum ratings (T A Ordering code Type (untaped) SIOV- B72210S0511K101 S10K510 B72214S0511K101 S14K510 B72220S0511K101 S20K510 B72210S0551K101 S10K550 B72214S0551K101 S14K550 B72220S0551K101 S20K550 B72210S0621K101 S10K625 B72214S0621K101 S14K625 B72220S0621K101 S20K625 B72210S0681K101 S10K680 B72214S0681K101 S14K680 B72220S0681K101 S20K680 B72214S0102K101 S14K1000 B72220S0102K101 S20K1000 1) Operating voltage differs from type designation. ...

Page 12

Leaded varistors StandarD series = 25 °C) Characteristics (T A Ordering code mA) V B72210S0511K101 820 B72214S0511K101 820 B72220S0511K101 820 B72210S0551K101 910 B72214S0551K101 910 B72220S0551K101 910 B72210S0621K101 1000 B72214S0621K101 1000 B72220S0621K101 1000 B72210S0681K101 1100 B72214S0681K101 1100 B72220S0681K101 ...

Page 13

Dimensional drawing ø Seating plane to IEC 60717 Dimensions ±1 Ordering code mm B72205S0110K101 5.0 B72207S0110K101 5.0 B72210S0110K101 7.5 B72214S0110K101 7.5 B72220S0110K101 10.0 B72205S0140K101 5.0 B72207S0140K101 5.0 B72210S0140K101 7.5 B72214S0140K101 7.5 B72220S0140K101 10.0 B72205S0170K101 ...

Page 14

Leaded varistors StandarD series Dimensions ±1 Ordering code mm B72205S0250K101 5.0 B72207S0250K101 5.0 B72210S0250K101 7.5 B72214S0250K101 7.5 B72220S0250K101 10.0 B72205S0300K101 5.0 B72207S0300K101 5.0 B72210S0300K101 7.5 B72214S0300K101 7.5 B72220S0300K101 10.0 B72205S0350K101 5.0 B72207S0350K101 5.0 B72210S0350K101 7.5 B72214S0350K101 7.5 B72220S0350K101 10.0 B72205S0400K101 ...

Page 15

Dimensions ±1 Ordering code mm B72205S0950K101 5.0 B72207S0950K101 5.0 B72210S0950K101 7.5 B72214S0950K101 7.5 B72220S0950K101 10.0 B72205S0111K101 5.0 B72207S0111K101 5.0 B72210S0111K101 7.5 B72214S0111K101 7.5 B72220S0111K101 10.0 B72205S0131K101 5.0 B72207S0131K101 5.0 B72210S0131K101 7.5 B72214S0131K101 7.5 B72220S0131K101 10.0 B72205S0141K101 5.0 B72207S0141K101 5.0 B72210S0141K101 ...

Page 16

Leaded varistors StandarD series Dimensions ±1 Ordering code mm B72205S0251K101 5.0 B72207S0251K101 5.0 B72210S0251K101 7.5 B72214S0251K101 7.5 B72220S0251K101 10.0 B72205S0271K101 5.0 B72207S0271K101 5.0 B72210S0271K101 7.5 B72214S0271K101 7.5 B72220S0271K101 10.0 B72205S0301K101 5.0 B72207S0301K101 5.0 B72210S0301K101 7.5 B72214S0301K101 7.5 B72220S0301K101 10.0 B72210S0321K101 ...

Page 17

Dimensions ±1 Ordering code mm B72205S0461K101 5.0 B72207S0461K101 5.0 B72210S0461K101 7.5 B72214S0461K101 7.5 B72220S0461K101 10.0 B72210S0511K101 7.5 B72214S0511K101 7.5 B72220S0511K101 10.0 B72210S0551K101 7.5 B72214S0551K101 7.5 B72220S0551K101 10.0 B72210S0621K101 7.5 B72214S0621K101 7.5 B72220S0621K101 10.0 B72210S0681K101 7.5 B72214S0681K101 7.5 B72220S0681K101 10.0 B72214S0102K101 ...

Page 18

Leaded varistors StandarD series Reliability data Test Test methods/conditions Varistor voltage The voltage between two terminals with the specified measuring current applied is called V Clamping voltage The maximum voltage between two terminals with the specified standard impulse current (8/20 ...

Page 19

Reliability data Test Test methods/conditions Climatic sequence CECC 42 000, test 4.16 The specimen shall be subjected to: a) dry heat at UCT damp heat, 1st cycle: c) cold, LCT damp heat, additional 5 ...

Page 20

Leaded varistors StandarD series Reliability data Test Test methods/conditions Resistance to soldering heat IEC 60068-2-20, test Tb, method 1A, 260 ° Each lead shall be dipped into a solder bath having a temperature of 260 ±5 °C to ...

Page 21

... K20 K25 20 K14 K17 K11 SIOV-S05 … Please read Cautions and warnings and Important notes at the end of this document. Leaded varistors StandarD series A = Leakage current B = Protection level B K420 K440 K460 K385 K300 K275 K250 K230 K175 K140 K150 K130 K115 K95 ...

Page 22

... K25 K30 K17 K20 20 K11 K14 SIOV-S07 … Please read Cautions and warnings and Important notes at the end of this document Leakage current B = Protection level B K420 K440 K460 K385 K300 K275 K250 K230 K175 K150 K140 K130 K115 K95 K75 K60 K40 ...

Page 23

... SIOV-S10 … Please read Cautions and warnings and Important notes at the end of this document. Leaded varistors StandarD series A = Leakage current B = Protection level B 460 440 680 625 550 510 420 385 320 300 275 250 230 175 150 140 130 115 95 75 ...

Page 24

... SIOV-S14 … Please read Cautions and warnings and Important notes at the end of this document Leakage current B = Protection level B 1000 420 440 680 625 550 510 460 385 320 300 275 250 230 175 150 140 130 115 ...

Page 25

... SIOV-S20 … Please read Cautions and warnings and Important notes at the end of this document. Leaded varistors StandarD series A = Leakage current B = Protection level B 1000 625 510 440 385 300 250 150 130 11/07 ...

Page 26

... Maximum surge current max For explanation of the derating curves refer to “General technical information”, section 1.8 max SIOV-S05K11 … K40 max SIOV-S05K50 … K460 Please read Cautions and warnings and Important notes at the end of this document. , pulse train 11/07 VAR0097-E i max µ ...

Page 27

... For explanation of the derating curves refer to “General technical information”, section 1.8 max SIOV-S07K11 … K40 max SIOV-S07K50 … K460 Please read Cautions and warnings and Important notes at the end of this document. Leaded varistors StandarD series , pulse train 11/07 VAR0018-Z ...

Page 28

... Maximum surge current max For explanation of the derating curves refer to “General technical information”, section 1.8 max SIOV-S10K11 … K40 max SIOV-S10K50 … K320 Please read Cautions and warnings and Important notes at the end of this document. , pulse train 11/07 VAR0100-3 i max µs 10 ...

Page 29

... For explanation of the derating curves refer to “General technical information”, section 1.8 max SIOV-S10K385 … K680 max SIOV-S14K11 … K40 Please read Cautions and warnings and Important notes at the end of this document. Leaded varistors StandarD series , pulse train 11/07 VAR0102-J i max ...

Page 30

... Maximum surge current max For explanation of the derating curves refer to “General technical information”, section 1.8 max SIOV-S14K50 … K320 max SIOV-S14K385 … K1000 Please read Cautions and warnings and Important notes at the end of this document. , pulse train 11/07 VAR0104-1 i max µs ...

Page 31

... For explanation of the derating curves refer to “General technical information”, section 1.8 max SIOV-S20K11 … K40 max SIOV-S20K50 … K115 Please read Cautions and warnings and Important notes at the end of this document. Leaded varistors StandarD series , pulse train 11/07 VAR0106-H i max ...

Page 32

... Maximum surge current max For explanation of the derating curves refer to “General technical information”, section 1.8 max SIOV-S20K130 … K320 max SIOV-S20K385 … K460 Please read Cautions and warnings and Important notes at the end of this document. , pulse train 11/07 VAR0168-7 i max µs ...

Page 33

... Derating curves Maximum surge current max For explanation of the derating curves refer to “General technical information”, section 1.8 max SIOV-S20K510 … K1000 Please read Cautions and warnings and Important notes at the end of this document. Leaded varistors StandarD series , pulse train 11/07 VAR0108-Y ...

Page 34

... Handling 1. SIOVs must not be dropped. 2. Components must not be touched with bare hands. Gloves are recommended. 3. Avoid contamination of the surface of SIOV electrodes during handling, be careful of the sharp edge of SIOV electrodes. Soldering (where applicable) 1. Use rosin-type flux or non-activated flux. 2. Insufficient preheating may cause ceramic cracks. ...

Page 35

... Potting, sealing or adhesive compounds can produce chemical reactions in the SIOV ceramic that will degrade the component’s electrical characteristics. 2. Overloading SIOVs may result in ruptured packages and expulsion of hot materials. For this rea- son SIOVs should be physically shielded from adjacent components. Operation 1 ...

Page 36

... The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSSP, DSSP, MiniBlue, MKK, MLSC, MotorCap, PCC, PhaseCap, PhaseMod, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www ...

Related keywords