CONTACT, FEMALE, 26-22AWG

1-104480-3

Manufacturer Part Number
1-104480-3
Description
CONTACT, FEMALE, 26-22AWG
Manufacturer
TE Connectivity
Type
Contactr
Series
AMPMODUr
Datasheets

Specifications of 1-104480-3

Pitch (mm)
Not Requiredmm
Gender
F
Number Of Contacts
1POS
Number Of Contact Rows
Not Required
Mounting Style
Cable
Body Orientation
Straight
Contact Plating
Gold Over Nickel
Operating Temp Range
-65C to 105C
Termination Method
Crimp
Current Rating (max)
3A
Voltage Rating Max
300VAC
Contact Material
Copper Alloy
Contact Resistance Max
12mOhm
Housing Material
Not Required
Housing Color
Not Required
Product Length (mm)
11.68mm
Product Depth (mm)
2.66mm
Connector Type
Wire To Board Contact
Current Rating
3A
Contact Size
22
Contact
RoHS Compliant
Product Type
Contact
Termination Method To Wire/cable
Crimp
Wire Insulation Diameter (mm [in])
0.64 – 1.52 [0.025 – 0.060]
Connector Series
Short Point
With Insulation Support
Yes
Applied Pressure
Standard
Contact - Rated Current (a)
3
Voltage Rating (vac)
300
Termination Resistance (m?)
12
Insulation Resistance (m?)
5,000
Dielectric Withstanding Voltage (v)
750
Crimp Area Plating
Tin
Wire Range (mm [awg])
0.12-0.40² [26-22]
Contact Type
Socket
Contact Plating, Mating Area, Material
Gold (30)
Contact Base Material
Copper Alloy C7025
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Approved Standards
UL E28476, CSA LR7189
Operating Temperature (°c)
-65 – +105
Applies To
Wire/Cable
Packaging Method
Strip
Packaging Quantity
50,000
Lead Free Status / RoHS Status
Compliant
For Use With
0.1 AMPMODU Headers, Housings

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
1-104480-3
Manufacturer:
TE
Quantity:
60 000
Dual Entry, End Stackable,
Low Profile, .100 x .100
[2.54 x 2.54] Centerline,
.200 [5.08] Tine Spacing
Material and Finish
Housing — Glass-filled thermoplastic,
black, 94V-0 rated
Plating A — Duplex .000030 [0.00076]
gold on contact area, .000150-0.000300
[0.00381-0.00762] matte tin on solder
area all over .000050 [0.00127] nickel
Plating B — Duplex .000010
[0.000254] gold on contact area,
.000150-.000300 [0.00381-0.00762]
matte tin on solder area all over .000050
[0.00127] nickel
Plating C — .000150-.000300
[0.00381-0.00762] matte tin on solder
leads, all over .000050 [0.00127] nickel
Note: All part numbers are RoHS
Catalog 1307819
Revised 8-08
www.tycoelectronics.com
compliant.
are metric equivalents.
Dimensions are in inches and
millimeters unless otherwise
specified. Values in brackets
AMPMODU Interconnection System
Mod IV Receptacle Assemblies, Single-Row, Outrigger Design
.100 x .100 [2.54 x 2.54] Centerline, End To End Stackable
Notes: 1. Tyco Electronics recommends mating gold or duplex plated headers with duplex plated receptacle
(Standoffs)
No. of
Pos.
[3.56]
[0.51]
.140
.020
10
11
12
13
14
15
16
17
18
19
20
30
40
3
4
5
6
7
8
9
2. To obtain the minimum mating post length, add .020 [0.51] (not including the post lead in chamfer) to
assemblies.
the maximum point-of-contact dimension and add .062 [1.57] for recommended board thickness if used in
bottom entry application.
1.000 [25.40]
1.100 [27.94]
1.200 [30.48]
1.300 [33.02]
1.400 [35.56]
1.500 [38.10]
1.600 [40.64]
1.700 [43.18]
1.800 [45.72]
1.900 [48.26]
2.000 [50.80]
3.000 [76.20]
4.000 [101.60]
.300 [7.62]
.400 [10.16]
.500 [12.70]
.600 [15.24]
.700 [17.78]
.800 [20.32]
.900 [22.86]
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
A
[2.54]
.100
Typ.
[3.56]
.140
Dimensions
A
Recommended PC Board Hole Layout
1.000 [25.40]
1.100 [27.94]
1.200 [30.48]
1.300 [33.02]
1.400 [35.56]
1.500 [38.10]
1.600 [40.64]
1.700 [43.18]
1.800 [45.72]
1.900 [48.26]
2.900 [73.66]
3.900 [99.06]
.200 [5.08]
.300 [7.62]
.400 [10.16]
.500 [12.70]
.600 [15.24]
.700 [17.78]
.800 [20.32]
.900 [22.86]
B
.075 +.005
[
1.90
USA: 1-800-522-6752
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
C. America: 52-55-1106-0803
[0.89±0.08]
.035±.003
-.000
+0.13
-.000
]
[1.34]
.053
Typ.
B
5-147720-2
5-147720-3
5-147720-4
5-147720-5
5-147720-6
5-147720-7
5-147720-8
5-147720-9
6-147720-0
6-147720-1
6-147720-2
6-147720-3
6-147720-4
6-147720-5
6-147720-6
6-147720-7
6-147720-8
7-147720-8
8-147720-8
8-147720-9
Plating A
Dia.
[6.22]
.245
(Localized Gold
Plate Area)
[3.17±0.25]
.125±.010
Contact Plating/Part Nos.
[2.72]
.107
Typ.
[2.54]
[3.77]
.100
Typ.
.148
Typ.
5-147726-2
5-147726-3
5-147726-4
5-147726-5
5-147726-6
5-147726-7
5-147726-8
5-147726-9
6-147726-0
6-147726-1
6-147726-2
6-147726-3
6-147726-4
6-147726-5
6-147726-6
6-147726-7
6-147726-8
7-147726-8
8-147726-8
8-147726-9
Plating B
South America: 55-11-2103-6000
Hong Kong: 852-2735-1628
Japan: 81-44-844-8013
UK: 44-8706-080-208
[5.08]
.200
Point of
Contact
5-147727-2
5-147727-3
5-147727-4
5-147727-5
5-147727-6
5-147727-7
5-147727-8
5-147727-9
6-147727-0
6-147727-1
6-147727-2
6-147727-3
6-147727-4
6-147727-5
6-147727-6
6-147727-7
6-147727-8
7-147727-8
8-147727-8
8-147727-9
Plating C
[5.08±0.08]
.200±.003
Typ.
181
5

Related parts for 1-104480-3

1-104480-3 Summary of contents

Page 1

... Notes: 1. Tyco Electronics recommends mating gold or duplex plated headers with duplex plated receptacle assemblies obtain the minimum mating post length, add .020 [0.51] (not including the post lead in chamfer) to the maximum point-of-contact dimension and add .062 [1.57] for recommended board thickness if used in Note: All part numbers are RoHS bottom entry application ...

Page 2

... Notes: 1. Tyco Electronics recommends mating gold or duplex plated headers with duplex plated receptacle assemblies obtain the minimum mating post length, add .020 [0.51] (not including the post lead in chamfer) to the maximum point-of-contact dimension and .062 for recommended board thickness if used in bottom entry application ...

Page 3

... Notes: 1. Tyco Electronics recommends mating gold or duplex plated headers with duplex plated receptacle assemblies obtain the minimum mating post length, add .020 [0.51] (not including the post lead in chamfer) to Note: All part numbers are RoHS the maximum point-of-contact dimension, and .062 [1.57] for recommended board thickness if used in bot- compliant ...

Page 4

... Catalog 1307819 Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified. Values in brackets www.tycoelectronics.com are metric equivalents. AMPMODU Interconnection System Mod. IV Receptacle Assemblies, Double-Row, .100 x .100 [2.54 x 2.54] Centerline Dimensions No. of Pos 2.100 [53.34] 2.000 [50.80] 44 2.200 [55.88] 2.100 [53.34 ...

Page 5

... AMPMODU Interconnection System Mod IV Surface Mount Vertical Receptacle Assemblies, .100 x .100 [2.54 x 2.54] Centerline Product Facts ■ Surface Mount Leads ■ Contact Material: phosphor bronze ■ High temperature, black thermoplastic housings, 94V-0 rated, capable of withstanding IR or vapor- phase reflow Gold/tin duplex plating ■ ...

Page 6

... Termination Resistance: 12 milliohms (max.) Insulation Resistance: 5000 megohms (min.) Mating Force (Receptacle Assemblies): 9.0 oz. [2.50N] (max.) per contact Unmating Force (Receptacle Assemblies): 1.5 oz. [0.42N] (min.) per contact Durability: Tested to 200 cycles (min.) for .000030 [0.00076] gold plated contacts Dimensions are shown for reference purposes only ...

Page 7

... Notes: 1. Tyco Electronics recommends mating gold or duplex plated headers with duplex plated receptacle assemblies obtain the minimum mating post length, add .020 [0.51] (not including the post lead in chamfer) to the maximum point-of-contact dimension, and .062 [1.57] for recommended board thickness if used in bottom entry application 3 ...

Page 8

... Notes: 1. Tyco Electronics recommends mating gold or duplex plated headers with duplex plated receptacle assemblies obtain the minimum mating post length, add .020 [0.51] (not including the post lead in chamfer) to the maximum point-of-contact dimension, and .062 [1.57] for recommended board thickness if used in bottom entry application. ...

Page 9

... AMPMODU Interconnection System Mod IV Surface Mount Receptacle Assemblies, Double-Row, .100 x .100 [2.54 x 2.54] Centers Surface Mount,Double Row, Dual Entry with Holddowns Material and Finish Housing — Glass-filled thermoplastic, black, 94V-0 rated Contacts — Phosphor bronze, plated as follows: Plating A — Duplex .000030 [0.00076] ...

Page 10

... Notes center holddown obtain the minimum mating post length, add .020 [0.51] (not including the post lead in chamfer) to the maximum point-of-contact dimension and .062 [1.57] for recommended board thickness in bottom entry applications. 5 190 ...

Page 11

... AMPMODU Interconnection System Mod IV Surface Mount Receptacle Assemblies, Double-Row, .100 x .100 [2.54 x 2.54] Centerline Surface Mount,Double Row, Dual Entry .100 End to End Stackable [2.54] Typ. .198±.002 [5.03±0.05] .265 [6.73] Material and Finish Typ. Housing — Glass-filled thermoplastic, black, 94V-0 rated Contacts — ...

Page 12

... Notes obtain the minimum mating post length, add .020 [0.51] (not including the post lead in chamfer) to the maximum point-of-contact dimension and .062 [1.57] for recommended board thickness in bottom entry applications. 5 192 Catalog 1307819 ...

Page 13

... Component Program of Underwriters Laboratories Inc., R File No. E28476 ■ Certified by Canadian Standards Association, R File No. LR 7189 5-534972-2 Vertical Receptacle 5-102690-3 Vertical Header with ACTION PIN Posts Note: All part numbers are RoHS compliant. Catalog 1307819 Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified ...

Page 14

... Durability (Tested to) — 200 cycles energized connector for .000030 [0.00076] gold plating; Voltage Rating — 250 VAC 75 cycles for .000015 [0.00038] gold Dielectric Rating — 750 VAC rms plating between contacts for one minute Mating Force — 8 oz. [2.22N] Termination Resistance — ...

Page 15

... Notes: 1. .115 [2.92] tail length is for use with .062 [1.57] PC boards; .145 [3.68] tail length is for use with .093 [2.36] PC boards. Notes: 2. Receptacle assemblies with low force contacts are available, consult Tyco Electronics. 3. .256 [6.50] minimum positive pin stop to prevent shorting between rows. ...

Page 16

... Catalog 1307819 Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified. Values in brackets www.tycoelectronics.com are metric equivalents. AMPMODU Interconnection System Receptacle Assemblies, Board Mount, Double-Row, Closed Entry, .100 x .100 [2.54 x 2.54] Centerline .115 [2.92] .410 [10.41] B ±.008 [±0.20] .100 Typ. ...

Page 17

... AMPMODU Interconnection System Receptacle Assemblies, Board Mount, Triple-Row, Closed Entry, .100 x .100 [2.54 x 2.54] Centerline Horizontal Mount (with Guide Pin Slots and Standoffs) .179 Typ. [4.55] Material and Finish .338 Housing — Glass-filled thermoplastic, [8.59] black, 94V-0 rated .144 Contacts — Phosphor bronze, plated [3 ...

Page 18

... Tyco Electronics. 198 Catalog 1307819 Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified. Values in brackets www.tycoelectronics.com are metric equivalents. AMPMODU Interconnection System Headers, Straight Post, Double-Row, .100 x .100 [2.54 x 2.54] Centerline Pos. Ref .100 [2.54] .085 .200 [2.16] [5.08] B ...

Page 19

... Headers with ACTION PIN posts are for use with .093 [2.36] nominal or thicker PC boards. 2. Application tooling for installing headers with ACTION PIN posts is shown on pages 152 and 153. 3. Headers with .250 [6.35] tail length can be made available with make first/break last contacts, consult Tyco Electronics ...

Page 20

... Tyco Electronics. 200 Catalog 1307819 Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified. Values in brackets www.tycoelectronics.com are metric equivalents. AMPMODU Interconnection System Headers, Right-Angle Post, Double-Row, .100 x .100 [2.54 x 2.54] Centerline .762 Max. [19.35] .599 [15.21] .040 A [1.02] Typ. ...

Page 21

... AMPMODU Interconnection System Headers, Straight Post, Triple-Row, .100 x .100 [2.54 x 2.54] Centerline Solder Posts (with Pin Protection and Guide Pins) .100 [2.54] .100 [2.54] .085 [2.16] .040 [1.02] (4 Sides) Material and Finish Housing — Glass-filled thermoplastic, black, 94V-0 rated .210 [5.33] Posts — ...

Page 22

... Catalog 1307819 Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified. Values in brackets www.tycoelectronics.com are metric equivalents. AMPMODU Interconnection System Headers, VRM (Voltage Regulator Module), .100 x .100 [2.54 x 2.54] Centerline A B .110 [2.79] .440 [11.18] B .100 [2.54] .125 [3 ...

Page 23

... Shroud Board Mounted PC Board Straight Posts Typical Assembly Technical Documents — page 276 Double-Row, .100 x .100 [2.54 x 2.54] Centers Part No. 102114-1 Material — Black glass-filled polyester Note: All part numbers are RoHS compliant. Catalog 1307819 Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified ...

Page 24

... For Shrouded Double-Row, 3 and 4 Sided Headers, .100 x .100 [2.54 x 2.54] Centers See Fig. 2 See Fig. 4 Note: Right-angle (Figs. 2 and 3) and “T” (Fig. 1) configurations of barrier insert establish polarization; bar (Fig. 4) configuration of barrier insert compartmentalizes header. Note: All part numbers are RoHS compliant. Dimensions are shown for reference purposes only ...

Page 25

... Material Black thermoplastic, flame retardant Part Numbers 499991-2 (Packaged 50 per bag) 499991-3 (Packaged 1000 per bag) Related Product Data Low Profile Headers used with — pages 135-140 Catalog 1307819 Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified. Values in brackets www ...

Page 26

... File No. LR 7189 Performance Characteristics Contact Current Rating — 3 amperes Termination Resistance — 12 milliohms (max.) — Gold plated contacts 16 milliohms (max.) — Tin plated contacts Durability — Ref. Product Specification 108-36028 and 108-36028-1 206 Catalog 1307819 Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified ...

Page 27

... AMP-O-LECTRIC Model “G” machines (shown on page 270), as well as other bench machines and fully automatic AMPOMATOR lead making machines. Notes: 1. These contacts must be crimped in accordance with Tyco Electronics Specification No. 114-25006 in order to function properly in a connector housing. 2. Extraction Tool No. 91084-1 is used for removing individual contacts from connector housings and for detaching contacts from mating posts. ...

Page 28

... AMPMODU Interconnection System Wire-Applied Housings for Locking Clip Contacts, Single-Row, .100 [2.54] Centerline A C Typ. .085 [2.16] .100 Typ. [2.54] B Note: Housing illustrated above is the “Both Ends Closed” version. No. of Dimensions Pos .108 [2.74] — 2 .216 [5.49] .100 [2.54] 3 ...

Page 29

... Length) .025 [0.64] Sq. Post A (Shown for Ref. only) .100 Typ. [2.54] .100 [2.54] .058 B [1.47] Note: Housing illustrated above is the “Both Ends Closed” version. Both Ends Closed Key Keyway Right End Open No. of Dimensions Pos .116 [2.95] — 4 .216 [5.49] ...

Page 30

... Values in brackets www.tycoelectronics.com are metric equivalents. AMPMODU Interconnection System Mod IV Wire-Applied Contacts and Housings 1-87631-5 D-R Housing, Polarized with Detent 6-87756-6 Std. Pressure Contacts 102387-1 D-R Ejection Housing, Center Polarized 6-87756-6 Std. Pressure Contacts 1825851-1 Latch 5102154-1 Hdr ...

Page 31

... AMP-O-LECTRIC Model “K” machines. Call the Technical Support Center (1-800-522-6752) for part nos. [0.00038] gold on contact area, with gold of applicators for use with the AMP-O-LECTRIC Model “G” machines (shown on page 270), as well as other bench flash over .000050 [0.00127] nickel on machines and fully automatic AMPOMATOR lead making machines ...

Page 32

... Plating D — Selectively plated .000050 [0.00127] gold on contact area, with gold flash over .000050 [0.00127] nickel on entire contact Plating E — Selectively plated .000030 [0.00076] gold on contact area, with gold flash over ...

Page 33

... Ph Bz **For use with AMP-O-LECTRIC Model “K” machines. Call the Technical Support Center (1-800-522-6752) for part nos. of applicators for use with the AMP-O-LECTRIC Model “G” machines (shown on page 270), as well as other bench machines and fully automatic AMPOMATOR lead making machines. ...

Page 34

... Notes: 1. Strain reliefs are available and may be purchased separately. Consult Tyco Electronics. Notes: 2. Contact Extraction/Lance Reset Tool No. 843996-3. Note: All part numbers are RoHS compliant. ...

Page 35

... AMPMODU Interconnection System Mod IV Wire-Applied Housings, Single-Row, .100 [2.54] Centerline Polarized (with Detent Latching) .175 [4.45] Material Black thermoplastic, flame retardant .071 Related Product Data [1.80] Contacts — pages 211-213 Mateable Headers and Posts — pages 115, 116 .056 Flexible Film Connectors, [1.42] Single-Row Pin Assemblies — ...

Page 36

... Notes: 1. Strain reliefs are available and may be purchased separately. Consult Tyco Electronics. Notes: 2. Contact Extraction/Lance Reset Tool No. 843996-3. Note: All part numbers are RoHS compliant. ...

Page 37

... Notes: 1. Strain reliefs are available and may be purchased separately. Consult Tyco Electronics. Part No. 87077-2 Notes: 2. Contact Extraction/Lance Reset Tool No. 843996-3. (Plugs directly into housing) Note: All part numbers are RoHS compliant ...

Page 38

... Notes: 1. The Strain Relief/Pull Tab can be bonded to any thermoplastic connector housing. Notes: 2. Strain reliefs may be purchased separately. Notes: 3 ...

Page 39

... Notes: 1. The Strain Relief/Pull Tab can be bonded to any thermoplastic connector housing. Notes: 2. Strain reliefs may be purchased separately. Notes: 3. Contact Extraction/Lance Reset Tool No. 843996-3. ...

Page 40

... Catalog 1307819 Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified. Values in brackets www.tycoelectronics.com are metric equivalents. AMPMODU Interconnection System Mod IV Wire-Applied Housings, Double-Row, .100 x .100 [2.54 x 2.54] Centerline Position No. 1 Indicator .130 [3.30 .120 C [3.05] X .227 [5 ...

Page 41

... Mates with .025 [0.64] ■ square posts ■ Dual cantilever contact beams for reliable matings ■ Locking retention latch provides approximately 3 lb [13. retention force 5-104450-3 MTE Hdr ■ Unique locking latch design helps prevent latch from protruding through latch window Contacts snap into ■ ...

Page 42

... Gap Extraction/Lance Reset Tool No. 843477-1 Contact Part No. (Standard Pressure) Finish Strip Form Loose Piece Plating A 1-104481-1 1-104481-3 Plating B 1-104481-0 1-104481-2 Plating C 5-104481-2 5-104481-6 Plating A 1-104480-3 1-104480-6 . Plating B 1-104480-2 1-104480-5 Plating C 1-104480-7 1-104480-4 Plating A 1-104479-0 1-104479-3 . Plating B 104479-9 1-104479-2 Plating C 104479-8 1-104479-1 Note: All part numbers are RoHS compliant ...

Page 43

... AMPMODU Interconnection System Short Point Wire-Applied Housings, Double-Row, Non-Polarized, .100 x .100 [2.54 x 2.54] Centerline Material Black thermoplastic, flame retardant, 94V-0 rated Related Product Data .049 [1.24] Performance Characteristics — page 221 Contacts — page 222 Mateable Headers — .100 pages 104, 105 [2 ...

Page 44

... Catalog 1307819 Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified. Values in brackets www.tycoelectronics.com are metric equivalents. AMPMODU Interconnection System Short Point Wire-Applied Housings, Double-Row, Polarized, .100 x .100 [2.54 x 2.54] Centerline A .100 [2.54] .049 [1.24] X .100 X .100 Typ. ...

Page 45

... At 70,000 Ft. [21 336 m]–225 VAC, rms Insulation Resistance — 5,000 megohms (min.) Environmental Characteristics Operating Temperature — -65°C to +105°C Vibration — 15 G’s (gold), 10 G’s (tin) Physical Shock — 50 G’s Industrial Mixed Flow Gasing — Class 1 (20 days) (gold) Product Specification 108-25034 ...

Page 46

... Receptacle Assemblies) 1 Mating AMPMODU Double-Row Shrouded Header Assemblies must have .318 [8.08] mating post length and .150 [3.81] dimension from centerline of last 1 post to inside of end shroud wall. Surface Mount Right-Angle and Vertical Headers are also available (see pages 251 and 252) ...

Page 47

... AMPMODU Interconnection System MTE Interconnection System Wire-to-Wire Pin Assemblies, Shrouded Polarized/Latching (See pages 236 & 237) Receptacle Assemblies, Polarized/Latching (See pages 230 & 231) Receptacle Contact, Insulation Displacement (Used in all Receptacle Assemblies) Crimp Snap-In Receptacle Contact (Used with Unloaded Housings— ...

Page 48

... Note: Insulation displacement contacts 5 accept an insulation diameter of .030 [0.76] min. to .054 [1.37] max. with an insula- tion wall thickness of .015 [0.38] max. Mating post length for preloaded housings is .200 [5.08] min., .250 [6.35] max. Related Product Data Mateable AMPMODU Products Breakaway Headers — ...

Page 49

... Notes: 1. Receptacle assemblies are furnished with strip contacts partially inserted into housing—contacts latched into “preload” windows. Contacts are fully inserted into housings automatically when terminated with Tyco Electronics application machines, or manually when terminated with Tyco Electronics pistol grip hand tool. ...

Page 50

... Note: Insulation displacement contacts accept an insulation diameter of .030 [0.76] 5 min. to .054 [1.37] max. with an insula- tion wall thickness of .015 [0.38] max. Mating post length for preloaded housings is .200 [5.08] min., .250 [6.35] max. Related Product Data ...

Page 51

... Notes: 1. Receptacle assemblies are furnished with strip contacts partially inserted into housing—contacts latched into “preload” windows. Contacts are fully inserted into housings automatically when terminated with Tyco Electronics application machines, or manually when terminated with Tyco Electronics pistol grip hand tool. ...

Page 52

... Note: Insulation displacement contacts accept an insulation diameter of .030 [0.76] 5 min. to .054 [1.37] max. with an insula- tion wall thickness of .015 [0.38] max. Mating post length for preloaded housings is .200 [5.08] min., .250 [6.35] max. Related Product Data Coupling Shrouds used with — ...

Page 53

... Notes: 1. Receptacle assemblies are furnished with strip contacts partially inserted into housing—contacts latched into “preload” windows. Contacts are fully inserted into housings automatically when terminated with Tyco Electronics application machines, or manually when terminated with Tyco Electronics pistol grip hand tool ...

Page 54

... Notes: 1. Receptacle assemblies are furnished with strip contacts partially inserted into housing—contacts latched into “preload” windows. Contacts are fully inserted into housings automatically when terminated with Tyco Electronics application machines, or manually when terminated with Tyco Electronics pistol grip hand tool ...

Page 55

... AMPMODU Interconnection System MTE High Pressure Receptacle Assemblies – Guide Ribs Preassembled housings in strip form are available in positions 2 thru 12. For ease of handling, positions 2 thru 5 are recom- mended when using the Tyco Electronics Manual Pistol Grip Tool. Material and Finish Housing — Thermoplastic, black, 94V-0 rated Contacts — ...

Page 56

... Plating C — .000100 [0.00254] tin over .000050 [0.00127] nickel on entire contact 5 Note: Insulation displacement contacts accept an insulation diameter of .030 [0.76] min. to .054 [1.37] max. with an insula- tion wall thickness of .015 [0.38] max. Related Product Data Mateable AMPMODU Products — Receptacle Assemblies (Polarized/Latching) — ...

Page 57

... Notes: 1. Pin assemblies are furnished with strip contacts partially inserted into housing—contacts latched into “preload” windows. Contacts are fully inserted into housings automatically when terminated with Tyco Electronics application machines, or manually when terminated with Tyco Electronics pistol grip hand tool ...

Page 58

... Note: Insulation displacement contacts 5 accept an insulation diameter of .030 [0.76] min. to .054 [1.37] max. with an insula- tion wall thickness of .015 [0.38] max. Related Product Data Mateable AMPMODU MTE Products (with Pin Assembly Installed in Panel Mount Pin Shroud) — ...

Page 59

... Notes: 1. Pin assemblies are furnished with strip contacts partially inserted into housing—contacts latched into “preload” windows. Contacts are fully inserted into housings automatically when terminated with Tyco Electronics application machines, or manually when terminated with Tyco Electronics pistol grip hand tool ...

Page 60

... Mount Pin Shroud (Refer to pages 238, 239 & 242) Single-Row Coupling Shroud Headers, Polarized/Latching, Straight and Right Angle Post, with or without Holddown (See pages 244-252) USA: 1-800-522-6752 South America: 55-11-2103-6000 Canada: 1-905-470-4425 Hong Kong: 852-2735-1628 Mexico: 01-800-733-8926 Japan: 81-44-844-8013 C. America: 52-55-1106-0803 UK: 44-8706-080-208 ...

Page 61

... Ribs (Refer to pages 232, 233 & 235) 1 Mating AMPMODU Double-Row Shrouded Headers must have .318 [8.08] mating post length and .150 [3.81] dimension from centerline 1 of last post to inside of end shroud wall. Typical Application of Double-Row Coupling Shroud and Mating AMPMODU Products Note: All part numbers are RoHS compliant ...

Page 62

... Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified. Values in brackets www.tycoelectronics.com are metric equivalents. AMPMODU Interconnection System Panel Mount Pin Shrouds for MTE Pin Assemblies with Guide Ribs, Single-Row A Position No. 1 Identification .320 [8.13] B Dimensions No. of Panel Mount Pos. Pin Shroud ...

Page 63

... Pin Assembly with Guide Ribs (Refer to pages 238 & 239) Panel Mount Pin Shroud Receptacle Assembly, Polarized/Latching (Refer to pages 230 & 231) Dimensions are shown for USA: 1-800-522-6752 reference purposes only. Canada: 1-905-470-4425 Specifications subject Mexico: 01-800-733-8926 to change. C. America: 52-55-1106-0803 ...

Page 64

... Retention Tails) Recommended PC Board Hole Layout *±.003 [±0.08]; tolerances not to accumulate within one connector pattern. Note: Swaged retention tails are provided in a minimum of two locations per header. Dimensions are shown for reference purposes only. ...

Page 65

... Notes: 1. Selectively loaded headers are available, consult Tyco Electronics. 2. Use Keying Tool No. 91417-1 to remove post for keying. Note: All part numbers are RoHS compliant. Catalog 1307819 Dimensions are in inches and ...

Page 66

... Typ. [2.54] X .120 [3.05] X .060 [1.52] .100* Typ. [2.54] Recommended PC Board Hole Layout *±.003 [±0.08]; tolerance not to accumulate within one connector pattern. Dimensions are shown for reference purposes only. Specifications subject to change. .535 [13.59] .100 .230 [2.54] [5.84] .200 .200 [5 ...

Page 67

... Notes: 1. Selectively loaded headers are available, consult Tyco Electronics. 2. Use Keying Tool No. 91417-1 to remove post for keying. Note: All part numbers are RoHS compliant. Catalog 1307819 Dimensions are in inches and ...

Page 68

... Dia. Typ. [1.02±0.08] (for Retention Tails) Recommended PC Board Hole Layout *±.003 [±0.08]; tolerances not to accumulate within one connector pattern. Note: Swaged retention tails are provided in a minimum of two locations per header. Dimensions No. of Pos ...

Page 69

... Typ. Header Profile (Shown for .075±.003 orientation purposes only) [1.90±0.08] Recommended PC Board Hole Layout (Stencil Thickness = .010 [0.25]) *±.003 [±0.08] tolerance not to accumulate within one connector pattern Dimensions A B .300 [7.62] .220 [5.59] .100 [2.54] .400 [10.16] ...

Page 70

... Typ. [1.78±0.51] .035±.003 Dia. Typ. C [0.89±0.08] Plated-Thru Hole Recommended PC Board (Stencil Thickness = .010 [0.25]) *±.003 [±0.08]; tolerance is not to accumulate within one connector pattern. Right-Angle No. of Header Pos. C with Hold Down .100 [2.54] 5-104361-1 14 ...

Page 71

... K Plating B — Duplex plated .000015 [.00038] gold on contact area, .000100 [.00254] min. tin on solder area, with entire post underplated .000050 [.00127] nickel. Plating C — .000100 [.00254] tin over .262 [6.65] .000050 [.00127] nickel on entire post K Recommended PC Board Layout (Refer to MTE Application Spec. ...

Page 72

... Plating B — Duplex plated .000015 [.00038] gold on contact area, .000100 [.00254] min. tin on solder area, with entire post underplated .000050 [.00127] nickel. Plating C — .000100 [.00254] tin over ...

Page 73

... Heavy Duty Miniature Contact Part No. Applicator for (Standard Pressure) AMP-O-LECTRIC Strip Form Loose Piece Machine* 1-104481-1 1-104481-3 1-104481-0 1-104481-2 567296-2 5-104481-2 5-104481-6 1-104480-3 1-104480-6 1-104480-2 1-104480-5 567297-2 1-104480-7 1-104480-4 1-104479-0 1-104479-3 104479-9 1-104479-2 567298-2 104479-8 1-104479-1 Dimensions are shown for USA: 1-800-522-6752 reference purposes only ...

Page 74

... AMP-O-LECTRIC Model “K” machines. Call Technical Support Center (1-800-522-6752) for part nos. of applicators for use with the AMP-O-LECTRIC Model “G” machines (shown on page 270), as well as other bench machines and fully automatic AMPOMATOR lead making machines. Note: These wire crimp contacts can be intermixed with insulation displacement crimp contacts. ...

Page 75

... Max. Mating Force — High pressure - 26 oz. [7.23 N] Standard pressure - 9 oz. [2.50 N] Min. Unmating Force — High pressure — 5 oz. [1.39 N] Standard pressure — 1.5 oz. [0.417 N] Contact Retention in Housing — 5 lb. [22.24 N] per contact min. South America: 55-11-2103-6000 Hong Kong: 852-2735-1628 ...

Page 76

... Material — Natural color nylon 256 Catalog 1307819 Dimensions are in inches and Revised 8-08 millimeters unless otherwise specified. Values in brackets www.tycoelectronics.com are metric equivalents. AMPMODU Interconnection System MT Receptacle Assemblies, Double-Row .100 x .100 [2.54 x 2.54] Centerline .600 [15.24 Max. .100 ...

Page 77

... Application Specification 18 114-25032 20 Instruction Sheet *Cavity identification — first cavity (one side); Tyco Electronics Part No. and date code stamped on housing where size permits. 408-6532 Note: Contact Extraction/Lance Reset Tool No. 843477-3, see page 265. Keying Plugs Part No. 86286-1 (Plugs into receptacle contact) Part No. 87077-2 Material — ...

Page 78

... AMPMODU Interconnection System Low Profile Covers for Double-Row MT Receptacle Assemblies Front Covers A - Polarizing Cover (Mates with AMPMODU 4-sided shrouded headers. Refer to pages 117, 122, 126, 130.) .750 [19.05 Ejection Cover (Mates with AMP-LATCH universal ejection style pin headers equipped with latching ears, Part No ...

Page 79

... Values in brackets www.tycoelectronics.com are metric equivalents Ejection Cover (Mates with AMP-LATCH universal ejection style pin headers equipped with latching ears, Part No. 102185-2 (with push tabs) or Part No. 102312-2 (without push tabs), see Tyco Electronics Catalog 82012. 1.120 Assembled* [28.45] Top View ...

Page 80

... Shields for right-angle headers have integral cantilever beams which provide good contact with the mating shielded MT receptacle assembly, without the use of a separate RF gasket. USA: 1-800-522-6752 South America: 55-11-2103-6000 Canada: 1-905-470-4425 Hong Kong: 852-2735-1628 Mexico: 01-800-733-8926 Japan: 81-44-844-8013 C. America: 52-55-1106-0803 UK: 44-8706-080-208 ...

Page 81

... AMPMODU Interconnection System Shielding Hardware and Accessories for Double-Row MT Receptacle Assemblies Two-Piece Shields— Straight Exit Material and Finish Shell Halves — Copper alloy, .020 [0.51] thick; pretinned .000030 [0.00076] min. Related Product Data Double-Row MT Receptacle Assemblies — pages 256, 257 Non-Polarizing Covers (Part No ...

Page 82

... Notes: 1. Match shield size to number of connector positions. 2. Hole is provided in 26 through 60-position cable shields for application of optional cable tie pull ring after assembly. Note: All part numbers are RoHS compliant. Dimensions are shown for reference purposes only ...

Page 83

... Model “K” machines. Call the Tyco Electronics Technical Support Center (1-800-522-6752) for part nos. of applicators for use with the AMP-O-LECTRIC Model “G” machines (also shown on page 270), as well as other bench machines and fully automatic AMPOMATOR lead making machines. ...

Page 84

... D ±.003 [±0.08] [2.54±0.08] ±.003 2D [±0.08] Recommended PC Board Hole Layout for 6, 8 and 10 Positions D - Contact centerline is .100 [2.54]; ±.003 [0.08] tolerances not to accumulate within one connector pattern. Dimensions No. of Pos .200 [5.08] .430 [10.92] 8 ...

Page 85

... AMPMODU Interconnection System Replacement MT Receptacle Contacts Insulation Displacement Contacts Material and Finish Copper alloy, duplex plated .000030 [0.00076] gold in mating area, .000100- .000200 [0.00254-0.00508] tin in crimp area, with entire contact underplated .000050 [0.00127] nickel Related Product Data Performance Characteristics — Wire Size Range ...

Page 86

... Single-row housings can be [3.18] and when used in a converted into double-row housing, they will mate with connectors on .100 x .200 .140 [3.55] long posts. [2.54 x 5.08] centers with These versatile contacts the use of stacking clips ...

Page 87

... Max. A Max. [2.54] .050 .100 [2.54] [1.27] B Spaces @ .100 [2.54 Minimum mating post length is .140 [3.55]. Dimensions A B .200 [5.08] 1 .400 [10.16] 3 .800 [20.32] 7 1.200 [30.48] 11 1.600 [40.64] 15 1.800 [45.72] 17 2.000 [50.80 ...

Page 88

... AMPMODU Interconnection System Mini-Tandem Spring Housings, Double-Row .550 [13.97] A Max. .200 [5.08] .100 [2.54] B Spaces @ .100 [2.54 Minimum mating post length is .140 [3.55]. Dimensions No. of Pos .300 [7.62] 8 .400 [10.16] 12 .600 [15.24] 16 .800 [20.32] Note: Mini-Tandem Spring contacts for use in these housings are shown on page 269. ...

Page 89

... AMP-O-LECTRIC Model “K” machines. Call the Tooling/Technical Assistance Center (1-800-522-6752) for part nos. of applicators for use with the AMP-O-LECTRIC Model “G” machines (shown on page 270), as well as other bench machines and fully automatic AMPOMATOR lead making machines. ...

Page 90

... Values in brackets www.tycoelectronics.com are metric equivalents. AMPMODU Interconnection System Application Tooling for Wire Crimp Contacts AMP-O-LECTRIC Model “G” Terminating Machine (Shown with Optional Crimp Force Monitor) A totally new design of our most popular machine for bench-top operation. It features a quiet and reliable ...

Page 91

... Values in brackets www.tycoelectronics.com are metric equivalents. (Continued) AMP 5K/40 Terminator Dimensions are shown for USA: 1-800-522-6752 reference purposes only. Canada: 1-905-470-4425 Specifications subject Mexico: 01-800-733-8926 to change. C. America: 52-55-1106-0803 5 271 South America: 55-11-2103-6000 Hong Kong: 852-2735-1628 Japan: 81-44-844-8013 UK: 44-8706-080-208 ...

Page 92

... In fact, that’s how you standardize your process. But for ongoing quality control, testing every crimp, SLE is the choice. It’s known worldwide, and meets our standards for a high performance terminating system. That’s how you can be sure. ...

Page 93

... This capability frees the operator’s hands for optimum positioning. Modular Heads: 58062-1 (for MT connectors) 58336-1 (for MTE connectors) 58395-1 (for Level V IDC connectors) 58540-1 (for MTE connectors, discrete wire or flat ribbon cable) Modular Head Tool No. 58540-1 This modular head tool can be used on any pistol grip tool ...

Page 94

... The feed track is a constant force, *At a rate of 13-25 positions at a time. 2700 lb. Power Unit With Cable Notching Die Equipped with a cable notching die an adapter kit, this fully pneumatic bench ...

Page 95

... Termination sequence may include full termination of all contacts, or selective termi- nation. Designed for easy programming, the machine is microprocessor controlled CHAMPOMATOR Model 3A Terminating Machine No. 761420-(*) This floor model machine automatically sorts wires from multiconductor jack- eted cable and terminates them in a user-determined sequence ...

Page 96

... Receptacle Assemblies, Horizontal and Vertical Board Mount — Pages 168-192: 408-7411 Suggestions for Wave Soldering Vertical AMPMODU Receptacles .025 [0.64] Square Posts, Headers, Accessories and Tooling — Pages 92-105, 114-140, 145-153, 163: 408-2636 ACTION PIN Contact Rear Insertion/Extraction Tool 265871-7 408-6944 ...

Page 97

... Short-Point Wire-Applied Contacts and Housings — Pages 221-224: 114-25038 AMPMODU MTE Interconnection System — Pages 225-252: 114-25026 AMPMODU MT and Shielded MT Interconnection System — Pages 255-265: 114-25032 AMPMODU Level V, IDC Connectors — 114-25020 Mini-Tandem Spring Receptacle Contacts — Pages 266-269: 114-25021 Note: All part numbers are RoHS compliant ...

Page 98

... AMPMODU MT Connectors AMPMODU Level V, IDC Connectors — 408-6843 Tyco Electronics Extraction Tool 91409-1 Standard Tandem Spring and Mini-Tandem Spring Receptacle Contacts — Pages 266-269: 408-7909 Tyco Electronics Hand Crimping Tool 91540-1 Note: All part numbers are RoHS compliant. Dimensions are shown for reference purposes only ...