6-1394461-5 TE Connectivity, 6-1394461-5 Datasheet

PLUG, SOLARLOK, 6MM, POS

6-1394461-5

Manufacturer Part Number
6-1394461-5
Description
PLUG, SOLARLOK, 6MM, POS
Manufacturer
TE Connectivity
Series
SolarLokr
Datasheets

Specifications of 6-1394461-5

Gender
M
Body Orientation
Straight
Housing Material
Polyphenylene Oxide
Number Of Contacts
1POS
Number Of Ports
1Port
Number Of Terminals
1
Current Rating (max)
25A
Pitch (mm)
Not Requiredmm
Contact Material
Copper Zinc
Operating Temp Range
-40C to 105C
Mounting Style
Cable
Contact Plating
Silver
Product Depth (mm)
18mm
Connector Type
Photovoltaic
Contact Termination
Crimp
No. Of Contacts
1
Connector Mounting
Cable
Colour
Black
Rohs Compliant
Yes
Connector Mounting Orientation
Cable
Product Type
Connector
Insulation Diameter (mm [in])
5.50 - 8.00 [.216 - .315]
Type Of Connector
Cable Coupler
Wire Size (mm² [awg])
6.0² [10]
Keying
Plus
Contact Base Material
Copper Zinc
Contact Finish
Silver Plate
Housing Color
Black
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Packaging Quantity
100
Lead Free Status / RoHS Status
Compliant
SOLARLOK
Interconnection System
RoHS
Ready

Related parts for 6-1394461-5

6-1394461-5 Summary of contents

Page 1

SOLARLOK Interconnection System RoHS Ready ...

Page 2

... Table of Contents The SOLARLOK Concept . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Large Junction Box – Serial Interconnection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Large Junction Box – Parallel Interconnection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Medium Junction Box – Serial Interconnection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Small Junction Box – Serial Interconnection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Mini Junction Box – Serial Interconnection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Cable Coupler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 T-Branch Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 DC/AC Converter Receptacle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 AC Inverter Connector ...

Page 3

... Different cable diameters of the world’s energy mix. ■ Operating Temperature from –40 ° +120 °C ■ Voltage Rating up to 2600 V DC ■ IEC 60228 Class 5 (stranded tin plated copper and flexible) ■ TÜV certified acc. to 2Pfg 1169/08.2007 ■ ...

Page 4

... Configuration Number 1-1394723-6 2-1394723-6 0-1394723-4 0-1394723-3 2 All specifications subject to change. Consult Tyco Electronics for latest specifications Interconnection Options Package Plug Connector Quantity Plus Keyed Minus Keyed Catalog 889753-3 Revised 6-2008 W: 150 Contact Diodes Rails Direct Wire oo oooooo oo oooooo oooo oo oooooo oooooo ...

Page 5

... Part Package Configuration Number Quantity 1394723-5 1394723-6 1394723-9 All specifications subject to change. Consult Tyco Electronics for latest specifications. Interconnection Options Plug Connector Plus Keyed Minus Keyed Catalog 889753-3 Revised 6-2008 W: 150 Contact Diodes Rails Direct Wire oooooo oooo oooooo oooo oooooo 3 ...

Page 6

... Plus Keyed Minus Keyed black solar cable and plug connector. 2 black solar cable and two plug connectors. Catalog 889753-3 Revised 6-2008 W: 115 mm H: 22.5 mm Contact Diodes Rails Direct Wire oo oooo ooo SL1010 oo oooo ooo SL1010 oooo ooo SL1010 oooo ooo SL1010 oo oooo ...

Page 7

... Minus Keyed black solar cable and plug connector. 2 black solar cable and two plug connectors. Catalog 889753-3 Revised 6-2008 (continued) W: 115 mm H: 22.5 mm Contact Diodes Rails Direct Wire ooo SL1010 oo oooo ooo SL1515 ooo SL1010 oo oooo ooo SL1515 ooo SL1010 oooo ...

Page 8

... All specifications subject to change. Consult Tyco Electronics for latest specifications Interconnection Options Package Plug Connector Quantity Plus Keyed Minus Keyed black solar cable and plug connector. 2 black solar cable and plug connectors. Catalog 889753-3 Revised 6-2008 Contact Diodes Rails Direct Wire oo ooo oo ooo oo oo ooo oo oo ooo oo ooo ...

Page 9

... All specifications subject to change. Consult Tyco Electronics for latest specifications Interconnection Options Package Plug Connector Quantity Plus Keyed Minus Keyed black solar cable and two plug connectors. 2 black solar cable and two plug connectors. Catalog 889753-3 Revised 6-2008 (continued Contact Diodes Rails Direct Wire ooo ooo oo ooo oo ooo ooo oo ooo oo 7 ...

Page 10

... Junction Box Assembly with two 85 cm long 4 All specifications subject to change. Consult Tyco Electronics for latest specifications Package Contact Rail Quantity Shape ✱ 80 Straight ✱ 80 Right-Angle 2 black solar cable and plug connector. Catalog 889753-3 Revised 6-2008 Contact Direct Wire Diodes Rails ...

Page 11

... Not Keyed, only for Junction Box Serial Interconnection All specifications subject to change. Consult Tyco Electronics for latest specifications. Male Cable Coupler Minus Keyed Plus Keyed 0-1394462-2 0-1394461-1 0-1394462-4 0-1394461-3 5-1394462-6 6-1394461-5 Wire Size Male Cable Coupler 2 (mm ) 2.5 6-1394461-1 4.0 6-1394461-2 6.0 ...

Page 12

... All specifications subject to change. Consult Tyco Electronics for latest specifications. T-Branch Connector Plus Keyed Minus Keyed o o T-Branch Connector Plus Keyed Minus Keyed o o Catalog 889753-3 Revised 6-2008 Package Part Number Quantity 1534611-1 20 1534611-2 20 Package Part Number Quantity 1740277-1 20 1740277-2 ...

Page 13

... Catalog 889753-3 Revised 6-2008 With Cover Remarks 100 100 O-Ring and Metal Nut 100 100 100 100 Flat Seal and Plastic Nut – Black 100 100 100 Flat Seal and Plastic Nut – Red 100 Flat Seal and Plastic Nut – ...

Page 14

... VDE certified • UL pending Configuration 5 Pole Receptacle o Receptacle o Header o Assembly o Assembly o 12 All specifications subject to change. Consult Tyco Electronics for latest specifications. Cable Length 200 mm Metall Nut Plastic Nut Catalog 889753-3 Revised 6-2008 Package Part Number Quantity 1740483 1740483-2 24 1740479-1 24 1740493 1740493-2 24 ...

Page 15

... At Short Circuit: +250 °C Test Voltage for 5 Minutes: Min. Operating Temperature 6000 V Free Installation: –25 °C Max. Current Carrying Capacity Fixed Installation: –40 °C (Free in Air): Wire Size Range 116 A (size dependent) 2 2.5 mm (AWG 14), 2 4.0 mm (AWG 12), 2 6.0 mm (AWG 10) Min ...

Page 16

... Red 1-956299-5 0-956299-6 Blue 1-956299-6 Color Part Number (Inch) -1986166-2 0.17 Black -1986166-3 -1986165-2 0.19 Black -1986165-3 -1986164-2 0.21 Black -1986164-3 Catalog 889753-3 Revised 6-2008 Package Quantity Approbation (m) (Feet) TÜV 500 – o 100 – o 500 – o 100 – o 500 – o 100 – ...

Page 17

... Compact, standardized design ■ Proven quality ■ One- / two-pole switch ■ Main switch function ■ Lockable ■ Current ■ Voltage up to 900 V U All specifications subject to change. Consult Tyco Electronics for latest specifications. Collecting ■ strings input ■ Cable cross section ■ ...

Page 18

... Cable Assembly Version 1 m 2-1987376-1 2-1987376 1-1987376-1 1-1987376-2 2-1987376-1 2-1987376-2 3 Catalog 889753-3 2 Female Cable Coupler (+) 1394462-3 Female Cable Coupler (–) 1394462-4 Female Cable Coupler (+) 1394462-3 Inverter Part Numbers for Cable Length 2-1987376-3 2-1987376-4 1-1987376-3 1-1987376-4 2-1987376-3 2-1987376-4 Revised 6-2008 2-1987376-5 1-1987376-5 2-1987376-5 ...

Page 19

... Female Cable Coupler (–) 1394462-4 Female Cable Coupler (+) 1394462-3 Inverter Female Cable Coupler (–) 1394462-4 Female Cable Coupler (+) 1394462-3 Part Numbers for Cable Length 2-1987376-3 2-1987376-4 1-1987376-3 1-1987376-4 2-1987376-3 2-1987376-4 3-1987376-3 3-1987376-4 4-1987376-3 4-1987376-4 Revised 6-2008 2-1987376-5 1-1987376-5 2-1987376-5 3-1987376-5 4-1987376-5 17 ...

Page 20

... All specifications subject to change. Consult Tyco Electronics for latest specifications. Termination times are meas- With a tensile strength of up ured in seconds using the to 36 kg, the UV-resistant pre-mounted Tyco Electronics enclosure provides a secure SolKlip thereby saving time termination even in roughest and reducing wiring costs environmental and assembly substantially ...

Page 21

... Click Click Click Standards and Specifications SolKlip Grounding Clip: UL 467 pending, a requirement for UL 1703 solar panel listing. UL 486A-B pending, also a requirement as part of the UL 1703 approval listing. Materials Housing: Durable PPT Contact: High conductivity copper alloy Catalog 889753-3 Revised 6-2008 • ...

Page 22

... SOLARLOK Interconnection System Interconnection Examples Serial Interconnection for Junction Boxes with Cable Glands 1394462-4 1394461-4 1394462-4 1394738-4 20 All specifications subject to change. Consult Tyco Electronics for latest specifications. 2 (4.0 mm Wiring) DC/AC Converter Catalog 889753-3 Revised 6-2008 6-1394461-2 1394462-3 1394462-3 1394738-3 ...

Page 23

... SOLARLOK Interconnection System Interconnection Examples Serial Interconnection for Junction Boxes with Plug Connectors 1394462-4 1394462-3 1394462-4 1394738-4 All specifications subject to change. Consult Tyco Electronics for latest specifications. (continued) 2 (4.0 mm Wiring) 1394462-4 DC/AC Converter Catalog 889753-3 Revised 6-2008 1394462-3 1394462-3 1394738-3 21 ...

Page 24

... Hand Crimping Tool incl. Vario Crimp Head and Locator Part No. 1579004-8 2 (for 1.5 + 2.5 + 4 Die Set Part No. 6-1579001-6 2 (for 1.5 + 2.5 + 4 Extraction Tool suitable for all wire sizes Part No. 1102855-3 Insulation Stripper includes length stop for all wire sizes: 1 ...

Page 25

... Part No. 1579007-2 Dioden / Jumper Spring Clamp Tool Part No. 1579007-5 Foil Spring Clamp Tool Part No. 1579007-3 Large Box Part No. 1740969-1 Medium Box Part No. 1740969-2 Small Box Kit includes the following parts: ■ 100 Cable Coupler (Housings, Plus and Minus coded) ■ Crimp Contacts 2 (4 ...

Page 26

... Part No. 1394465-4 The grommet has to be matched with the outer diameter of the solar cable (see customer drawing, Part No. 1394461 and Part No. 1394462) and the pinch ring (Part No. 1418677-2) must be applied. 24 All specifications subject to change. Consult Tyco Electronics for latest specifications. ...

Page 27

... Place seal/pinch ring combination into the connector housing until it stops. 4 Place backshell onto the connector housing. 5 Push contact with cable into the connector housing until you hear the contact is locked into position 6 Tighten backshell nut to 1.5 Nm All specifications subject to change. Consult Tyco Electronics for latest specifications. Catalog 889753-3 ...

Page 28

... The “neutral” designated pin connectors incorporate no keying features and must only be used for Serial Interconnection of Photovoltaic Modules. The neutral product should not be used where maintaining polarity is critical disconnect the connector by pulling the connector halves apart. Catalog 889753-3 Fig. 7 (Female Connector) CAUTION: Do not disconnect the connector under load! Revised 6-2008 Fig. 8 ...

Page 29

... The panel thickness must not be under 1.0 mm. ■ For environmental protection of the unmated connector, use of the covering cap is recommended. Cover: Part No. 1394739-1 All specifications subject to change. Consult Tyco Electronics for latest specifications. Catalog 889753-3 (continued) Revised 6-2008 Fig. 9 Fig. 10 Fig. 11 Fig. 12 Fig ...

Page 30

... Technical Description 28 All specifications subject to change. Consult Tyco Electronics for latest specifications. (continued) Fig. 15: Parallel (Wire Diagram) Hand Tool, integral Locator and Die (Part No. 1-1105851-8), use ‘HVT’ position on locator Hand Tool, only (Part No. 539973-1) Catalog 889753-3 Revised 6-2008 Fig. 16 ...

Page 31

... Diameter 18 mm, (diameter 0.71 inch) –40 °C to +105 °C AWG 14, AWG 12, AWG 10 stranded wire IP 67, mated silver plated, 50, silver plated 30 – 40 Newton Coded housing ensures mating safety Contact voltage-proof Connector with crimp technology IEC 61215 Edition 2, 61646, IEC 61730, Protection Class II, UL 1703 29 ...

Page 32

... 1418867-6 1-1105851-8 28 1-1418867-2 1394461-1 9 1-1418867-3 1394461-2 9 1534226-1 1394461-3 9, 16, 17 1534611-1 1394461-4 9, 16, 17, 1534611-2 20 1534858-1 6-1394461-1 9 1579000-4 6-1394461 5-1579001-4 6-1394461-4 9 5-1579001-5 6-1394461-5 9 6-1579001-6 6-1394461-6 9 7-1579001-8 1394462-1 9 7-1579001-9 1394462-2 9 8-1579001-2 1394462-3 9, 16, 17, 4-1579002-2 20, 21 1579004-8 1394462-4 9, 16, 17, 1-1579004-1 20, 21 1-1579004-2 5-1394462-5 9 1579007-2 5-1394462-6 9 ...

Page 33

... RoHS Compliant Part numbers in this catalog are RoHS Compliant, unless marked otherwise. These products comply with European Union Directive 2002/95/EC as amended 1 January 2006 that restricts the use of lead, mercury, cadmium, hexavalent chromium, PBB, and PBDE in certain electrical and electronic products sold into the July 2006. ...

Page 34

... SOLARLOK Interconnection System Engineering Notes 32 All specifications subject to change. Consult Tyco Electronics for latest specifications. Catalog 889753-3 Revised 6-2008 ...

Page 35

... For Latin/South American Countries not shown Phone: +54-11-4733-2015 +57-1-660-0206 Fax: +54-11-4733-2083 New Zealand – Auckland Phone: +64-9-634-4580 +81-44-812-3207 Fax: +64-9-634-4586 Philippines – Makati City Phone: +632-848-0171 +81-44-812-3200 Fax: +632-867-8661 People’s Republic of China Hong Kong +82-2-3486-3810 Phone: +852-2735-1628 Fax: +852-2735-0243 Shanghai +60-3-7805-3066 ...

Page 36

... Tyco Electronics AMP GmbH Siemensstr. 13 67346 Speyer / Germany Phone: +49-(0)6232-30-2520 Fax: +49-(0)6232-30-2243 www.tycoelectronics.com AMP, SOLARLOK, SOLKLIP, TE Logo and Tyco Electronics are trademarks. © 2008 Tyco Electronics Ltd. 889753-3 Revised 6-2008 5M ST ...

Related keywords