Page 1
... BNC Plug 58 31-5560-RFX BNC Plug Plenum 59, 62 Step Step 2 Step 3 Amphenol Corporation Tel: 800-627-7100 outer ferrule plug body assembly Hex Crimp Data Cavity for Die Set for CTL Series Outer Ferrule Tool 227-944* Tool Number .324(8.2) 227-1221-32 CTL-2 .324(8.2) ...
Page 2
... For angle plugs only: (except 31-204) Solder center conductor to preassembled contact. Assemble cap and lightly punch center of cap for retention in body, or solder in place. Amphenol Corporation Tel: 800-627-7100 clamp bushing‡ female contact jack body ‡ For use on RG-62, 71, 122, 178, 180, 196, 210 ...
Page 3
... For RG-174, 179, 187, 188, 316/U cables only, slit jacket back .100"(2.5mm) as shown. Before attaching center contact, slide metal spacer/TFE sleeve (not shown) over cable dielectric and under braid. The center contact should butt against the dielectric and TFE sleeve. Amphenol Corporation Tel: 800-627-7100 outer ferrule bushing male contact ...
Page 4
... Step 2 contact must butt against cable dielectric Step 3 cable dielectric must butt insulator outer ferrule should butt here crimp here Amphenol Corporation Tel: 800-627-7100 bushing male contact plug body assembly used with RG-62, 71, 210 cable only Hex Crimp Data Cavity for ...
Page 5
... Step 5 note: center conductor must be visible thru contact solder hole prior to soldering Step 6 lip of boot must be firmly posi- Step 7 tioned in body groove Amphenol Corporation Tel: 800-627-7100 ferrule ferrule clamp nut assembly Hex Crimp Data Cavity for Cavity for Contact Outer Ferrule — ...
Page 6
... Assembly Instructions-C28 BNC SURETWIST ® PLUG .813 (20.7) .250 (6.4) Step 1 .563 (14.3) Step 2 .031 (0.8) Step 3 Back end of connector and cable dielectric flush, center conductor in place Step 4 Amphenol Corporation Tel: 800-627-7100 BNC SURETWIST® plug Amphenol Connector Cable Number Type ...
Page 7
... Use caution that braid slides over contact assembly and not inside of it. Be sure center conductor is visible through side hole of contact. Solder contact to center conductor. Contact may be crimped on applicable connectors using Amphenol CTL-1 crimp tool using die set 227-1221-13 cavity B in tool frame 227-944 or equivalent tool. Step 3 Insert into connector body ...
Page 8
... Assembly Instructions-C30 BNC PLUGS FCP TERMINATION outer ferrule Step 1 Step 2 Step 3 Step 4 Amphenol Corporation Tel: 800-627-7100 center plug body assembly contact Amphenol Connector Cable Number Type RG-/U 31-4700 BNC Plug 58, 141 31-4702 BNC Plug 59 .250(6.4) .156(4.0) Step 1 Slide ferrule over cable end, slotted end first. Strip cable to dimensions shown ...
Page 9
... Before attaching center contact, slide TFE sleeve (not shown) over cable dielectric and under braid. The center contact should butt against the dielectric and TFE sleeve. Step 2 Step 3 Amphenol Corporation Tel: 800-627-7100 CONNECTORS contact body assembly Stripping Dimensions, inches (mm) ...
Page 10
... The center contact should butt against the dielectric and TFE sleeve. Step 2 contact must butt against cable dielectric Step 3 cable dielectric must butt insulator outer ferrule should butt here Amphenol Corporation Tel: 800-627-7100 CONNECTORS plug body assembly female contact Hex Crimp Data Cavity for Cavity for ...