Test Procedures for Board Testing
Overview
Equipment Required
Actel Equipment Provided by Actel to Testing Facility
Testing Facility Equipment to be Available for Testing
Test Procedure for the A3PE-A3P-EVAL-BRD1
Initial Power-On Procedure
ProASIC3/E Starter Kit User’s Guide and Tutorial
This document defines the test procedure required to be carried out by the Actel designated manufacturer's testing
facility on the ProASIC3/E Evaluation Board with silkscreen labeling A3PE-A3P-EVAL-BRD-1. This testing is
specific to the socketed version of the board. All steps in the following enumerated test procedure should be followed in
sequence for testing the board. Deviations in the sequence are explained in the text.
Actel will provide the following:
• This test procedure document.
• FlashPro v3.4 software on a CD-ROM.
• FlashPro3 programmer and programming cable for connecting to the A3PE-A3P-EVAL-BRD1.
• Pre-programmed A3PE600-PQ208 or A3P250-PQ208 silicon. Ten devices will be provided for ten boards. The initial
• Power supply (+9 V, 2 A CUI) for the ProASIC3 Starter Kit board plus a mains cable for the power supply.
The manufacturer's testing facility will provide the following equipment for testing of the board:
• Digital Multimeter to measure voltages on the circuit board at the known test points.
In this section, full test procedure for the boards is outlined. This procedure applies to socketed boards. For boards fitted
with directly soldered parts, the procedure is the same except for fitting of the FPGA. In such cases, the reader should
adjust the procedure accordingly and ignore references to fitting parts to sockets.
This part of the procedure may be carried out independently and ahead of the other parts of the test procedure. Boards
passing this procedure may be transferred to a passing set of boards.
To perform the initial power-on procedure:
1.
2.
3.
4.
5.
silicon will not be labeled as having been programmed. (This is just for the testing associated with the first
manufacturing build.) Additional devices will be provided for testing further boards and this change will be detailed in
an update to the procedure.
Record the time of the test and the board serial number (written by the bar code on the back of the board) into a test
log.
Plug the +9 V power supply into the wall.
Take an A3PE-A3P-EVAL-BRD1 that has an empty socket. Make sure the switch SW11 is in the OFF position,
(the switch should be moved to the left). This corresponds with the labeling of the silkscreen on the board.
Connect +9 V DC output of the CUI power supply to the J18 connector on the board. You should observe the red
LED at the top right of the board, i.e. LED D19 should light indicating +9 V DC has been applied to the board.
Move the SW11 switch to the ON position, i.e., move the switch to the right. Observe that LEDs, D13, D9, D10,
D11, and D17 light up green on the board. All LEDs are on the top edge of the board (same edge as red D19 power
connector LED, which should remain lit).