GBU1002 Taiwan Semiconductor, GBU1002 Datasheet

no-image

GBU1002

Manufacturer Part Number
GBU1002
Description
Bridge Rectifiers 10 Amp 100 Volt 220 Amp IFSM
Manufacturer
Taiwan Semiconductor
Datasheet

Specifications of GBU1002

Product
Single Phase Bridge
Peak Reverse Voltage
100 V
Maximum Rms Reverse Voltage
70 V
Max Surge Current
220 A
Forward Voltage Drop
1.1 V
Maximum Reverse Leakage Current
5 uA
Maximum Operating Temperature
+ 150 C
Length
22.3 mm
Width
3.56 mm
Height
18.8 mm
Mounting Style
Through Hole
Minimum Operating Temperature
- 55 C
Package / Case
GBU
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
C2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
GBU1002A
Manufacturer:
ZV
Quantity:
20 000
Part Number:
GBU1002G
Manufacturer:
ZV
Quantity:
20 000
Features
Mechanical Data
Maximum Ratings and Electrical Characteristics
Rating at 25
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
@T
Peak Forward Surge Current, 8.3 ms Single
Half Sine-wave Superimposed on Rated
Load (JEDEC method )
Maximum Instantaneous Forward Voltage
Maximum DC Reverse Current @ T
at Rated DC Blocking Voltage @ T
Typical Junction Capacitance (Note 3)
Typical Thermal Resistance Per Leg ( Note 1 )
Operating Temperature Range
Storage Temperature Range
Notes
Type Number
C
= 100
lengths.
UL Recognized File # E-96005
Ideal for printed circuit board
Reliable low cost construction
Plastic material has Underwriters Laboratory
Flammability Classification 94V-0
High case dielectric strength of 1500VRMS
Surge overload rating to 200 amperes peak
High temperature soldering guaranteed:
260
Case: Molded plastic body.
Terminals: Plated leads solderable per
MIL-STD-750, Method 2026.
Mounting torque: 5 in. lb. Max.
Weight: 0. 3 ounce, 8.0 grams
1: Units Mounted In Free Air No Heat Sink On PCB 0.5”x 0.5 “ (12mm x 12mm) Copper Pads,
2: Device Mounted on 4” x 6” x 0.25” Plate Heatsink.
3. Measured at 1.0 MHZ and applied Reverse Voltage of 4.0V.
o
C / 10 seconds / .375”, (9.5mm) lead
o
C
0.375”(9.5mm) Lead Length.
o
C ambient temperature unless otherwise specified.
@ 5.0A
@ 10A
( Note 2 )
A
=125
A
=25
o
C
o
C
Symbol GBU
V
V
R
R
I
V
I
T
FSM
(AV)
RRM
V
RMS
Cj
I
T
STG
DC
R
F
J
1001
50
35
50
GBU
1002
100
100
.310(7.90)
.290(7.40)
.020R(TYP.)
70
Dimensions in inches and (millimeters)
.085(2.16)
.065(1.65)
.100(2.54)
.085(2.16)
211
GBU1001 - GBU1007
Single Phase 10.0 AMPS. Glass
.080(2.03)
.065(1.65)
GBU
1003
200
140
200
Passivated Bridge Rectifiers
.160(4.1)
.140(3.5)
-55 to + 150
-55 to +150
GBU
1004
.880(22.3)
.860(21.8)
10.0
400
280
400
220
500
1.0
1.1
5.0
2.0
21
.075
(1.9)R
.190(4.83)
.210(5.33)
GBU
1005
GBU
600
420
600
.050(1.27)
.040(1.02)
0.125(3.2)x45
.080(2.03)
.060(1.52)
CHAMFER
GBU
1006
800
560
800
.710(18.0)
.690(17.5)
94
.740(18.8)
.720(18.3)
GBU
1007
1000
1000
700
.140(3.56)
.130(3.30)
Version: A06
.022(0.56)
.018(0.46)
TYP.
9
Units
.085(2.16)
.075(1.90)
o
C/W
uA
uA
pF
o
o
V
V
V
A
A
V
C
C

Related parts for GBU1002

GBU1002 Summary of contents

Page 1

... RMS V 50 100 DC I (AV) I FSM = =125 C Cj 211 STG Passivated Bridge Rectifiers GBU .140(3.56) .880(22.3) .130(3.30) .860(21.8) 0.125(3.2)x45 CHAMFER .160(4.1) .140(3.5) .740(18.8) .720(18.3) .080(2.03) .075 (1.9)R .060(1.52) .710(18.0) .690(17.5) .050(1.27) .040(1.02) .190(4.83) .210(5.33) .080(2.03) .065(1.65) GBU GBU GBU GBU GBU ...

Page 2

RATINGS AND CHARACTERISTIC CURVES (GBU1001 THRU FIG.1-MAXIMUM FORWARD CURRENT DERATING CURVE HEAT-SINK MOUNTG 100mm x 100mm x 1 Cu. PLATE 0 50 100 0 CASE TEMPERATURE FIG.3- MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT ...

Related keywords