MODELS CUB 1 & CUB 2 COUNTERS
OPEN UP NEW COUNTING HORIZONS, FROM COUNTING SIMPLE SWITCH CONTACT CLOSURES
AND HERE ARE SOME MORE ADVANTAGES:
SELF POWERED
loss of count if power fails. Also provides for remote or portable applications.
Battery operation also means elimination of shock hazard and allows the use of
2-conductor bell wire for count signals and micro-power input signals.
life is four years.
HIGH SPEED
E.M. counters. This opens up vast new application areas that previously were
impossible, or at best, accommodated by expensive electronic counters costing
5 to 10 times as much.
FLEXIBILITY
outputs from electronic sensors and circuits. The reset function can be disabled,
set up for front panel reset, remote reset, or both.
SPECIFICATIONS
1. DISPLAY: 6-digit LCD
2. POWER SOURCE: No external power required. Operates from 2 “N” type
3. COUNT & RESET INPUT SIGNALS: Adapts to Count-Switch Contact
4. OPERATING TEMPERATURE RANGE: 0° to 50°C (32° to 122°F)
5. STORAGE TEMPERATURE RANGE: -20° to +60°C (-4° to +140°F)
Self-Contained batteries eliminate the need for external power and prevent
Batteries are easily replaceable (2 “N” Cells, alkaline) and average battery
The 5 KHz count speed is at least 100 times faster than “high performance”
Various count inputs allow use with switch contacts or high speed pulse
CUB 1: 0.2" (5 mm) high
CUB 2: 0.35" (9 mm) high
alkaline batteries (supplied separately). Battery life up to 4 years or more.
(See Note, at right.)
Signals, Open-Collector Transistor Outputs, and Bi-Polar Drive Outputs as
shown in the diagrams on the following page. Counter increments and resets
on negative going (pull down) transition of count or reset signal.
CUB 2 GENERAL PURPOSE
INDUSTRIAL COUNTER
USE CUB COUNTERS WITH:
VCM • VOLTAGE CONVERTER MODULES for isolated, A.C., control voltage count inputs to 270 VAC,
LCM • LOGIC CONVERTER MODULES for interface with standard logic voltages & outputs,
PSMA • POWER SUPPLY & INTERFACE MODULE for operation with electronic sensors.
CUB 1 MINIATURE
ELECTRONIC COUNTER
[See Accessory Section Of The Catalog]
1
Controls. This chip contains all of the counting and display circuits in an area
less than 0.02 (0.5 mm) square inches. Via “micro-assembly”, the chip and other
peripheral parts are attached to a substrate with the electrical connections being
made ultrasonically - using wire approximately 1/3 the diameter of a human
hair. The result is an entirely new concept in counting, that is not only cost
effective, but opens the door to counting applications that until now were not
economically feasible.
NO-WEAR, NO-NOISE
counts in one hour to completely wear out an ordinary E.M. counter. More over,
it can repeat this performance 3500 times (4 years) with just one set of batteries.
RELIABILITY
force of shock and vibration compared to conventional construction.
problems associated with contact corrosion.
mode rejection ratio of more than 120 dB @ 50/60 Hz, provides ultra-high
immunity from electrical noise interference.
RUGGED, SEALED FRONT-PANEL CONSTRUCTION
designed to meet NEMA 4/IP65 specifications, for wash-down and/or dust
when properly installed.
6. COUNT SPEED: Up to 50 Hz with switch contact input (counters have
Note: Only Alkaline Cells are recommended for use with CUB Counters. DO
ELECTRONIC SOURCES
MECHANICAL] COUNTERS
The heart of the CUB is a tiny custom silicon chip developed by Red Lion
The CUB’s micro-circuits can accurately and silently accumulate enough
Internal “micro-assembly” construction withstands many times the “G”
CUB counters also feature elastomeric contacts. This eliminates long term
Battery operation, a high degree of input filtering, plus an inherent common
Housed in a die-cast metal case, CUB counters are front panel sealed and
internal de-bounce circuits) or up to 5 KHz with solid-state electronic input
(See diagrams on following page).
NOT USE CARBON-ZINC BATTERIES since they have short life times
and can leak electrolyte causing internal corrosion damage. When using
switch contacts for count input or remote reset, normally open contact
circuits are recommended. Switch contacts that remain normally-closed and
are opened only briefly to signal a count, can reduce battery life to somewhat
less than 4 years.
TO HIGH SPEED PULSES FROM TTL, CMOS, OR OTHER
AT A PRICE LESS THAN EQUIVALENT E.M.[ELECTRO-
Bulletin No. CUB1/2-G
Drawing No. LP0001
Released: 8/05

Related parts for CUB10000

CUB10000 Summary of contents

Page 1

Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net MODELS CUB 1 & CUB 2 COUNTERS OPEN UP NEW COUNTING HORIZONS, FROM COUNTING SIMPLE SWITCH CONTACT CLOSURES CUB 1 MINIATURE ELECTRONIC COUNTER CUB 2 GENERAL PURPOSE INDUSTRIAL COUNTER AND HERE ...

Page 2

APPLICATION FLEXIBILITY VIA RECONNECT OPTIONS LOW SPEED COUNT INPUT MAX. [For 250 Hz see note in text] Pulling the L.S. CNT. Input to Common with a mechanical or solid-state switch increments the counter. The low pass filter (1meg ...

Page 3

... When using accessory devices such as LCMs or PSMs into the H.S. CNT. Input, the accessory devices should be mounted near the CUB Counter. PART NUMBERS NOTES CUB10000 1. Batteries NOT supplied with counters, order separately. CUB20000 2 required per unit. 2. Counters supplied with required hardware. Includes 2 mounting BNA00000 clips & ...

Page 4

... The Company disclaims all liability for any affirmation, promise or representation with respect to the products. The customer agrees to hold Red Lion Controls harmless from, defend, and indemnify RLC against damages, claims, and expenses arising out of subsequent sales of RLC products or products containing components manufactured by RLC and based upon personal injuries, deaths, property ...

Related keywords