AD260BND-0 Analog Devices Inc, AD260BND-0 Datasheet
AD260BND-0
Specifications of AD260BND-0
Related parts for AD260BND-0
AD260BND-0 Summary of contents
Page 1
FEATURES IsoLogic™ Circuit Architecture Isolation Test Voltage: To 3.5 kV rms Five Isolated Logic Lines: Available in Six I/O Configurations Logic Signal Bandwidth: 20 MHz (Min), 40 mbps (NRZ) Isolated Power Transformer p-p, 1.5 W Max CMV ...
Page 2
AD260–SPECIFICATIONS Parameter INPUT CHARACTERISTICS Threshold Voltage Positive Transition ( Negative Transition (V ) T– Hysteresis Voltage ( Input Capacitance ( Input Bias Current ( OUTPUT CHARACTERISTICS 1 Output Voltage High Level (V ...
Page 3
... Description AD260AND-0 0 Inputs, 5 Outputs AD260AND-1 1 Input, 4 Outputs AD260AND-2 2 Inputs, 3 Outputs AD260AND-3 3 Inputs, 2 Outputs AD260AND-4 4 Inputs, 1 Output AD260AND-5 5 Inputs, 0 Outputs AD260BND-0 0 Inputs, 5 Outputs AD260BND-1 1 Input, 4 Outputs AD260BND-2 2 Inputs, 3 Outputs AD260BND-3 3 Inputs, 2 Outputs AD260BND-4 4 Inputs, 1 Output AD260BND-5 5 Inputs, 0 Outputs CAUTION ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the human body and test equipment and can discharge without detection ...
Page 4
... AD260 AD260BND-0 AD260-0 LATCH F0 LINE 0 – OUT 18 LATCH F1 19 LINE 1 – OUT LATCH F2 20 LINE 2 – OUT LATCH F3 21 LINE 3 – OUT LATCH F4 22 LINE 4 – OUT ENABLE 17 FLD +5Vdc +5Vdc 16 FLD 5Vdc RTN 5V RTN 15 FLD 17V p-p OUT PWRA 14 FLD ...
Page 5
... PWRCT * FLD 14 PWRA * FLD RTN * FLD FLD 17 ENABLE * FLD 18 F0 (Rcv) F0 (Rcv (Rcv) F1 (Rcv (Rcv) F2 (Rcv (Rcv) F3 (Rcv (Rcv) F4 (Xmt) *Pin function is the same on all models, as shown in the AD260BND-0 column. REV. 0 PIN CONFIGURATIONS ENABLE ENABLE 6 17 SYS FLD +5Vdc +5Vdc +5Vdc ...
Page 6
AD260 (Continued from page 1) Integral Isolated Power: The AD260 includes an integral, uncommitted and flexible 1 Watt power transformer for devel- oping isolated field power sources. Field and System Enable Functions: Both the isolated and nonisolated sides of the ...
Page 7
The power transformer is designed to operate between 150 kHz and 250 kHz and will easily deliver more than isolated power when driven push-pull ( the system side. Different transformer tap, rectifier and regulator schemes ...
Page 8
AD260 0.160 (4.06) 0.140 (3.56) 0.075 (1.91) 0.250 (6.35) OUTLINE DIMENSIONS Dimensions shown in inches and (mm). 22-Lead Plastic DIP (ND-22) 1.500 (38.1) MAX 0.440 SIDE VIEW (11.18) MAX 0.100 (2.54) 0.050 (1.27) 0.020 0.010 (0.508 ...