ADF4360-9BCPZ Analog Devices Inc, ADF4360-9BCPZ Datasheet - Page 19

Synthesizer And VCO

ADF4360-9BCPZ

Manufacturer Part Number
ADF4360-9BCPZ
Description
Synthesizer And VCO
Manufacturer
Analog Devices Inc
Type
Fanout Distribution, Integer N Synthesizer (RF)r
Datasheet

Specifications of ADF4360-9BCPZ

Pll
Yes
Input
CMOS
Output
Clock
Number Of Circuits
1
Ratio - Input:output
1:2
Differential - Input:output
No/No
Frequency - Max
400MHz
Divider/multiplier
Yes/No
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
24-LFCSP
Frequency-max
400MHz
Number Of Elements
1
Supply Current
5mA
Pll Input Freq (min)
10MHz
Pll Input Freq (max)
250MHz
Operating Supply Voltage (typ)
3.3V
Operating Temp Range
-40C to 85C
Package Type
LFCSP EP
Output Frequency Range
1.1 to 400MHz
Operating Supply Voltage (min)
3V
Operating Supply Voltage (max)
3.6V
Operating Temperature Classification
Industrial
Pin Count
24
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADF4360-9BCPZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADF4360-9BCPZRL7
Manufacturer:
Maxim
Quantity:
618
Company:
Part Number:
ADF4360-9BCPZRL7
Quantity:
217
N COUNTER LATCH
Figure 24 shows the input data format for programming the
N counter latch.
5-Bit Divider
A5 to A1 program the output divider. The divide range is 2 (00010)
to 31 (11111). If unused, this divider should be set to 0. The output
or the output divided by 2 is available at the DIVOUT pin.
Reserved Bits
DB23, DB22, and DB7 are spare bits and are designated as
reserved. They should be programmed to 0.
B Counter Latch
B13 to B1 program the B counter. The divide range is 3
(00 … 0011) to 8191 (11 … 111).
Overall Divide Range
The overall VCO feedback divide range is defined by B.
CP Gain
DB21 of the N counter latch in the ADF4360 family is the
charge pump gain bit. When it is programmed to 1, Current
Setting 2 is used. When programmed to 0, Current Setting 1 is
used. This bit can also be programmed through DB10 of the
control latch. The bit always reflects the latest value written to it,
whether this is through the control latch or the N counter latch.
Rev. A | Page 19 of 24
R COUNTER LATCH
With (C2, C1) = (0, 1), the R counter latch is programmed.
Figure 25 shows the input data format for programming the
R counter latch.
R Counter
R1 to R14 set the counter divide ratio. The divide range is
1 (00 … 001) to 16,383 (111 … 111).
Antibacklash Pulse Width
DB16 and DB17 set the antibacklash pulse width.
Lock Detect Precision
DB18 is the lock detect precision bit. This bit sets the number of
reference cycles with <15 ns phase error for entering the locked
state. With LDP at 1, five cycles are taken; with LDP at 0, three
cycles are taken.
Test Mode Bit
DB19 is the test mode bit (TMB) and should be set to 0. With
TMB = 0, the contents of the test mode latch are ignored and
normal operation occurs, as determined by the contents of the
control latch, R counter latch, and N counter latch. Note that
test modes are for factory testing only and should not be
programmed by the user.
Band Select Clock
These bits (DB20 and DB21) set a divider for the band select
logic clock input. The output of the R counter is, by default, the
value used to clock the band select logic; if this value is too high
(>1 MHz), a divider can be switched on to divide the R counter
output to a smaller value (see Figure 25). A value of 8 is
recommended.
Reserved Bits
DB23 to DB22 are spare bits that are designated as reserved.
They should be programmed to 0.
ADF4360-9