CP1E-E30DR-A

Manufacturer Part NumberCP1E-E30DR-A
Description18In,12Out AC PS NonUL
ManufacturerOmron
CP1E-E30DR-A datasheet
 


Specifications of CP1E-E30DR-A

Lead Free Status / Rohs StatusLead free / RoHS Compliant  
1
Page 1
2
Page 2
3
Page 3
4
Page 4
5
Page 5
6
Page 6
7
Page 7
8
Page 8
9
Page 9
10
Page 10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
Page 10/44

Download datasheet (5Mb)Embed
PrevNext
CP1E-E@@D@-@ CP1E-N@@D@-@/NA20D@-@
Item
B-type Peripheral USB Port
Transmission
distance
Built-in RS-232C port
Communications
method
synchronization
Baud rate
Transmission
distance
Supported
protocol
Communications
Serial Option port
Mountable
Option Boards
Communications
method
synchronization
Baud rate
Compatible
protocols
Number of tasks
Maximum subroutine number
Maximum jump number
Scheduled interrupt tasks
Clock
Built-in EEPROM
Memory
Battery backup With
backup
CP1W-BAT01 Battery
(Sold separately)
Input Bits
CIO Area
Output Bits
Serial PLC Link Words
Work Area (W)
Holding Area (H)
Auxiliary Area (A)
Temporary Relay Area (TR) (TR Area)
Timer Area (T)
Counter Area (C)
Data Memory Area (D)
Operating modes
10
CP1E-E@@D@-@
Conforming to USB 2.0 B type connector
5 m max.
No built-in RS-232C port
Option Board cannot be mounted.
17
• One cyclic execution task
• One scheduled interrupt task (always interrupt task 1)
• Six input interrupt tasks (interrupt tasks 2 to 7)
• Sixteen high-speed counter interrupt tasks (interrupt tasks 1 to 16)
128
128
1 interrupt task
Clock function not included.
The time of error occurrence displays 01-01-01
01:01:01 Sunday
Ladder programs and parameters are automatically saved to built-in EEPROM
A section of the Data Memory Area can be saved to the built-in EEPROM.
Battery cannot be mounted.
1,600 bits (100 words): CIO 0.00 to CIO 99.15 (CIO 00 to CIO 99)
1,600 bits (100 words): CIO 100.00 to CIO 199.15 (CIO 100 to CIO 199)
1,440 bits (90 words): CIO 200.00 to CIO 289.15 (words CIO 200 to CIO 289)
1,600 bits (100 words): W0.00 to W99.15 (W0 to W99)
800 bits (50 words): H0.00 to H49.15 (H0 to H49)
Bits in this area maintain their ON/OFF status when operating mode is changed.
Read-only: 7,168 bits (448 words) A0 to A447
Read/write: 4,896 bits (306 words) in words A448 to A753
16 bits: TR0 to TR15
256 timer numbers (T0 to T255 (separate from counters))
256 counter numbers (C0 to C255 (separate from timers))
2 Kwords: D0 to D2047
Of these, 1,500 words can be saved to the backup
memory (built-in EEPROM) using settings in the
Auxiliary Area.
PROGRAM mode: Program execution is stopped.
Preparations can be executed prior to program execution in this mode.
MONITOR mode: Programs are executed.
Some operations, such as online editing, and changes to present values in I/O memory, are
enabled in this mode.
RUN mode: Programs are executed.
This is the normal operating mode.
CP1E-N@@D@-@
CP1E-NA@@D@-@
Interface: Conforms to EIA RS-232C.
Half duplex
Start-stop
1.2, 2.4, 4.8, 9.6, 19.2, 38.4, 57.6, or 115.2 kbps
15 m max.
• Host Link
• 1:N NT Link
• No-protocol mode
• Serial PLC Links (master, slave)
• Modbus-RTU Easy Master
1 port (Option Board can be mounted only to N30/40/
60 and NA20 CPU Units.)
• One RS-232C port: CP1W-CIF01
• One RS-422A/485 port (not isolated): CP1W-CIF11
• One RS-422A/485 port (isolated): CP1W-CIF12
• One Ethernet port: CP1W-CIF41
Depends on Option Board.
Depends on Option Board.
1.2, 2.4, 4.8, 9.6, 19.2, 38.4, 57.6, or 115.2 kbps
• Host Link
• 1:N NT Link
• No-protocol mode
• Serial PLC Links (master, slave)
• Modbus-RTU Easy Master
Included.
Accuracy (monthly deviation):
o
-4.5 min to -0.5 min at ambient temperature of 55
C,
o
-2.0 min to +2.0 min at ambient temperature of 25
C,
o
C
-2.5 min to +1.5 min at ambient temperature of 0
CP1W-BAT01 can be used.
Maximum battery service life: 5 years
Backup Time
o
Guaranteed value (ambient temperature: 55
C):
13,000 hours (approx. 1.5 years)
o
Effective value (ambient temperature: 25
C):
43,000 hours (approx. 5 years)
8 Kwords: D0 to D8191
Of these, 7,000 words can be saved to the backup
memory (built-in EEP-ROM) using settings in the
Auxiliary Area