CP1E-E30DR-A

Manufacturer Part NumberCP1E-E30DR-A
Description18In,12Out AC PS NonUL
ManufacturerOmron
CP1E-E30DR-A datasheet
 

Specifications of CP1E-E30DR-A

Lead Free Status / Rohs StatusLead free / RoHS Compliant  
1
2
3
4
5
6
7
8
9
10
11
Page 11
12
Page 12
13
Page 13
14
Page 14
15
Page 15
16
Page 16
17
Page 17
18
Page 18
19
Page 19
20
Page 20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
Page 18/44

Download datasheet (5Mb)Embed
PrevNext
CP1E-E@@D@-@ CP1E-N@@D@-@/NA20D@-@
Allocating Built-in Inputs to Functions
Input terminals are allocated functions by setting parameters in the PLC Setup. Set the PLC Setup so that each terminal is used for only one function.
Input terminal block
CPU Unit with
Normal
I/O Points
Terminal
Terminal
block
Normal
number
label
input
Normal
00
input 0
Normal
01
input 1
Normal
02
input 2
10
Normal
03
input 3
Normal
04
input 4
Normal
05
input 5
CIO 0
Normal
06
input 6
14
Normal
07
input 7
Normal
08
input 8
Normal
09
input 9
20
Normal
10
input 10
Normal
11
input 11
Normal
30
00 to 05
input 12
to17
CIO 1
Normal
40
06 to 11
input 18
to 23
Normal
60
CIO 2
00 to 11
input 24
to 35
18
Settings in PLC Setup
Interrupt input setting on
High-speed counter 0 to 3 setting on
Built-in Input Tab Page
Built-in Input Tab Page
Interrupt
Quick
Single-phase
Quick-
(increment
Input
response
pulse input)
interrupt
input
Counter 0,
--
--
increment input
Counter 1,
--
--
increment input
Interrupt
Quick-response
Counter 2,
input 2
input 2
increment input
Interrupt
Quick-response
--
input 3
input 3
Interrupt
Quick-response
Counter 3,
input 4
input 4
increment input
Interrupt
Quick-response
Counter 4,
input 5
input 5
increment input
Interrupt
Quick-response
Counter 5,
input 6
input 6
increment input
Interrupt
Quick-response
--
input 7
input 7
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Origin search settings on Pulse
Output 0/1 Tab Page
Two-phase
Two-phase
(differential
CPU Unit with
CPU Unit with
(pulse/
phase x4 or
20 to 60 points
direction)
up/down)
Counter 0, phase
Counter 0,
--
A or up input
pulse input
Counter 0, phase
Counter 1,
--
B or down input
pulse input
Counter 1, phase
Counter 0,
--
A or up input
direction
Pulse 0, Origin
Counter 1, phase
Counter 1,
--
proximity input
B or down input
direction
signal
Counter 0, phase
Counter 0,
--
Z or reset input
reset input
Pulse 1, Origin
Counter 1, phase
Counter 1,
--
proximity input
Z or reset input
reset input
signal
Pulse 0: Origin
Pulse 0, Origin
--
--
input signal
input signal
Pulse 1: Origin
Pulse 1, Origin
--
--
input signal
input signal
--
--
--
--
--
--
Pulse 0: Origin
--
--
proximity input signal
Pulse 1: Origin
--
--
proximity input signal
--
--
--
--
--
--
--
--
--
These functions are supported only by
N/NA-type CPU Units with transistor
outputs.
14 I/O points
--
--
--
--
--
--
--
--
--
--
--