CP1E-N20DT1-A Omron, CP1E-N20DT1-A Datasheet - Page 20

no-image

CP1E-N20DT1-A

Manufacturer Part Number
CP1E-N20DT1-A
Description
12In 8PNP RS232,AC PS,Non UL
Manufacturer
Omron
Datasheet

Specifications of CP1E-N20DT1-A

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
20
CP1E-E@@D@-@ CP1E-N@@D@-@/NA20D@-@
Allocating Built-in Output Terminals to Functions
Output terminals are allocated functions by setting parameters in the PLC Setup. Set the PLC Setup so that each terminal is used for only one function.
CPU Unit with
I/O points
60
40
30
20
14
10
block label
CIO 100
CIO 101
CIO 102
Terminal
Output terminal
block
Terminal
number
00 to 03
04 to 07
00 to 07
00
01
02
03
04
05
06
07
Normal output 0
Normal output 1
Normal output 2
Normal output 3
Normal output 4
Normal output 5
Normal output 6
Normal output 7
Normal output 8 to 11
Normal output 12 to 15
Normal output 16 to 23
Other than those
Normal output
shown right
Pulse output 0 (pulse)
Pulse output 1 (pulse)
Pulse output 0 (direction)
Pulse output 1 (direction)
When a pulse output instruction
(SPED, ACC, PLS2, or ORG) is
These functions are supported only by N/NA-type CPU Units with transistor outputs.
Pulse + direction
executed
--
--
--
--
--
--
--
Fixed duty ratio pulse output
Pulse 0: Error counter reset
Pulse 1: Error counter reset
Pulse Output 0/1 Tab Page
Origin search setting on
Setting in PLC Setup
output
output
Use
--
--
--
--
--
--
--
--
--
PWM output 0
instruction is executed
Variable duty ratio
When the PWM
pulse output
PWM output
--
--
--
--
--
--
--
--
--
--

Related parts for CP1E-N20DT1-A