KRP-11DG-6

Manufacturer Part NumberKRP-11DG-6
DescriptionKRP-11DG-6=KA/KB/KC/KR
ManufacturerTyco Electronics
SeriesKRP
KRP-11DG-6 datasheet
 


Specifications of KRP-11DG-6

Relay TypeGeneral PurposeContact FormDPDT (2 Form C)
Contact Rating (current)10ASwitching Voltage120VAC
Coil TypeStandardCoil Current188mA
Coil Voltage6VDCTurn On Voltage (max)4.5 VDC
Mounting TypeSocketTermination Style8 Pin Socketable
CircuitDPDT (2 Form C)Contact Rating @ Voltage10A @ 120VAC
Control On Voltage (max)4.5 VDCMounting StyleSocket
Power Consumption1.2 WContact MaterialSilver Cadmium Oxide
Coil Resistance32 OhmsLead Free Status / RoHS StatusLead free / RoHS non-compliant
Control Off Voltage (min)-Other names9-1393101-0
1
Page 1
2
Page 2
3
Page 3
4
Page 4
5
Page 5
Page 1/5

Download datasheet (140Kb)Embed
Next
KRPA
KRP
Features
• Industry standard octal-type termination for quick installation.
• Contact arrangements from 1 Form C (SPDT) to 3 Form C (3PDT).
• Indicator lamp and push-to-test options available on certain models.
• The KRPA is the automated manufactured version of the KRP .
Contact Data @ 25°C
Arrangements: See Ordering Information Table.
Materials: Silver or silver-cadmium oxide, with or without gold flashing.
Expected Life: 10 million operations min., mechanical; 100,000
operations min. @ rated loads.
KA, KRP , KRPA
UL/CSA Contact Ratings @ 25°C
Contact Code
Arrangement
Y
1, 2, 3 Poles
(Silver)
G&N
1, 2, 3 Poles
(Silver-Cad.
Oxide)
KRP , KRPA
Factory Ratings
Contact Code
Arrangement
Contact Rating
Y
1, 2, 3 Poles
5A @ 28VDC, 120VAC, 80% PF
G&N
1, 2, 3 Poles
10A @ 28VDC, 120VAC, 80% PF
6A @ 250VAC
KA UL Contact Ratings
Contact Code
Series
Contact Ratings
1
Y
KA
5A @ 120VAC, 3A @ 240VAC,
1/10 HP @ 120VAC, 1/6 HP @ 240VAC
2
G
KA
10A @ 120VAC, 6A @ 240VAC
1/6 HP @ 120VAC, 1/3 HP @ 240VAC
1
Listed by C.S.A. for 5A @ 120VAC 80% PF
2
Listed by C.S.A. for 10A @ 120VAC 80% PF
Note: See KRPA, KRP , KA Ordering Information table.
Initial Dielectric Strength
Between Open Contacts: 500V rms.
Between All Elements: 1,500V rms.
Dimensions are shown for
Dimensions are in inches over
reference purposes only.
(millimeters) unless otherwise
specified.
Catalog 1308242
PDF Revised 9-03
KRPA, KRP , KA, KR
5 to 10 Amp
General Purpose Relay
File E29244, E22575
File LR15734
Users should thoroughly review the technical data before selecting a product
KA
part number. It is recommended that users also seek out the pertinent approvals
files of the agencies/laboratories and review them to ensure the product meets
the requirements for a given application.
Coil Data @ 25°C
KRP
AC
KRPA
DC
KA
AC
DC
Duty Cycle: Continuous.
Initial Insulation Resistance: KRP , KRPA - 1000 Megohms, min.
Coil Data @ 25°C
Nominal
Voltage
Contact Rating
6
12
5A @ 120VAC
DC
24
3A @ 240VAC
Coils
48
1/10HP @ 120VAC
110
1/6HP @ 240VAC
220
10A @ 240VAC
6
1/2 HP @ 240VAC
AC
12
1/3HP @ 120VAC
Coils
24
120
240
Operate Data @ 25°C
Must-Operate Voltage:
DC: 75% or less of nominal voltage.
AC: 85% or less of nominal voltage.
Operate Time (Excluding Bounce):
15 milliseconds typical @ nominal voltage.
Release Time (Excluding Bounce):
10 milliseconds typical @ nominal voltage.
Environmental Data
Temperature Range:
Open Models: AC: -45°C to +70°C.
DC: -45°C to +85°C.
Enclosed Models: AC: -45°C to +55°C.
Mechanical Data
Termination: Open Models: Solder terminals.
Enclosed Models: Octal-type plug.
Enclosure: Transparent polycarbonate.
Weight: KA: 1.7 oz. (48.2g) approximately.
KRPA, KRP: 3.0 oz. (85g) approximately.
Specifications and availability
subject to change.
series
Nominal Power
Maximum Power
2VA
Enclosed Models - 4VA
1.2W
Enclosed Models - 3W
2VA
Open Models - 4VA
125mW per movable arm
Open Models - 4W
KA - 100 Megohms, min.
DC Resistance ( )
Nominal Coil
±10%
Current (mA)
32
188
120
100
472
51
1,800
26.6
10,000
11.5
Use 110V relay with 10,000
5W Resistor in series
6
335
24
168
85
84
2,250
17 .5
9,110
8.75
DC: -45°C to +70°C.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
P&B
737

KRP-11DG-6 Summary of contents

  • Page 1

    ... Industry standard octal-type termination for quick installation. • Contact arrangements from 1 Form C (SPDT Form C (3PDT). • Indicator lamp and push-to-test options available on certain models. • The KRPA is the automated manufactured version of the KRP . Contact Data @ 25°C Arrangements: See Ordering Information Table. ...

  • Page 2

    ... Ordering Information 1. Series: KRPA (Newer version, enclosed) KRP (Older version, enclosed) KA (Open style) 2. Contact Arrangement Form C (SPDT Form C (DPDT) 3. Coil Input AC, 50/60 Hz Contact Rating and Indicator Lamp Option: TYPE KRPA KRP Codes Available Y = Silver, no indicator lamp G = Silver-cadmium oxide, no indicator lamp N = Silver-cadmium oxide, with indicator lamp* 5 ...

  • Page 3

    ... Dimensions are shown for Dimensions are in inches over reference purposes only. (millimeters) unless otherwise specified. Catalog 1308242 PDF Revised 9-03 KRP-3-H 20 Amp Small Relays File E22575 Coil Data @ 25°C See chart on page 105. Nominal Power: DC Coils: 1.2W Initial Insulation Resistance: 1,000 megohms. ...

  • Page 4

    ... MAX. THREAD (48.8) Tolerances on .XX Decimals ± .02 (± .5) Unless Otherwise Specified Tolerances on .XXX Decimals ± .005 (± .13) Unless Otherwise Specified KR Series Enclosures Type “P” Clear Dust Cover For KRPA and KRP 1.406 MAX. (35.71) Wiring Diagrams (Bottom Views) KA KR5 KAP5 ...

  • Page 5

    ... Sockets For KRP , KRPA Series Relays The following sockets are normally maintained in stock for immediate delivery. Screw Terminal, DIN Rail Snap-Mount Sockets (Use with mounting track 24A110) 27E891 10A, 300VAC 1.295 (32.89) 1.005 (25.53) 2.010 (51.05) .165 (4.19) DIA.TYP . .312 TYP . ...