SR3XT43BD SQUARE D, SR3XT43BD Datasheet

no-image

SR3XT43BD

Manufacturer Part Number
SR3XT43BD
Description
ZELIO SR3 ANALOG OUTPUT 24VDC
Manufacturer
SQUARE D
Datasheet
Product data sheet
Characteristics
Complementary
Mar 30, 2012
Analogue input number
Analogue input type
Analogue input range
Temperature probe type
Maximum permissible voltage
[Imp] maximum permanent current
Analogue input resolution
Input impedance
Analogue output number
Analogue output range
Analogue output resolution
Load type
Maximum load current
Short-circuit protection
LSB value
Conversion time
Conversion error
Repeat accuracy
Operating distance
Reverse polarity protection
SR3XT43BD
analogue I/O extension module - 4 I O - 24 V
DC - for Zelio Logic
Main
Range of product
Product or component
type
2
Common mode
0...10 V
0...20 mA
-25...125 °C
Pt 100, 3-wire conforming to IEC 751
30 V for analogue input circuit
30 mA for analogue input circuit
10 bits on the input range
18 kOhm, input range: 0...10 V for analogue input circuit
247 Ohm, input range: 0...20 mA for analogue input circuit
2
0...10 V
10 bits on the output range
Resistive load for analogue output
10 mA for analogue output
With analogue output
0.15 °C, - 25...125 °C for analogue input circuit
20 µA, 0...20 mA for analogue input circuit
9.8 mV, 0...10 V for analogue input circuit
9.8 mV , 0...10 V for analogue output
Smart relay cycle time for analogue input circuit
Smart relay cycle time for analogue output
+/- 1 % of the full scale value, input range: 0...10 V (25 °C) for analogue output
+/- 1 % of the full scale value, input range: 0...10 V (55 °C) for analogue output
+/- 1 %, input range: 0...10 V (25 °C) for analogue input circuit
+/- 1 %, input range: 0...10 V (55 °C) for analogue input circuit
+/- 1 %, input range: 0...20 mA (25 °C) for analogue input circuit
+/- 1 %, input range: 0...20 mA (55 °C) for analogue input circuit
+/- 1.5 °C, input range: - 25...125 °C (25 °C) for analogue input circuit
+/- 1.5 °C, input range: - 25...125 °C (55 °C) for analogue input circuit
< +/- 0.3 °C, input range: - 25...125 °C at 25 °C for analogue input circuit
<= +/- 1 %, input range: 0...10 V at 25 °C for analogue input circuit
<= +/- 1 %, input range: 0...10 V at 55 °C for analogue output
<= +/- 1 %, input range: 0...20 mA at 25 °C for analogue input circuit
10 m with screened cable for analogue input circuit
10 m with screened cable for analogue output
With analogue input circuit
Zelio Logic
Analogue I/O extension module
1

Related parts for SR3XT43BD

SR3XT43BD Summary of contents

Page 1

... Load type Maximum load current Short-circuit protection LSB value Conversion time Conversion error Repeat accuracy Operating distance Reverse polarity protection Mar 30, 2012 SR3XT43BD analogue I/O extension module - for Zelio Logic Main Range of product Zelio Logic Product or component Analogue I/O extension module type 2 Common mode 0 ...

Page 2

Connections - terminals Tightening torque Product weight Environment Product certifications Standards IP degree of protection Environmental characteristic Disturbance radiated/conducted Pollution degree Ambient air temperature for operation Ambient air temperature for storage Operating altitude Altitude transport Relative humidity 2 Screw terminals, ...

Page 3

... Product data sheet Dimensions Drawings Analog I/O Extension Modules Mounting on 35 mm/1.38 in. DIN Rail Screw Fixing (Retractable Lugs) SR3XT43BD 3 ...

Page 4

... Connections and Schema Connection of Smart Relays on DC Supply, with Analog I/O Extension Module Connection Alternatives Application Example with Input and 1 x Pt100 Input (1) Screened cables, maximum length 10 m/32.80 ft. Application Example with Input and Input (1) Screened cables, maximum length 10 m/32.80 ft. 4 SR3XT43BD Pt100 ...

Page 5

... DC-12: control of resistive loads and of solid state loads isolated by opto-coupler, L/R ≤ 1 ms. DC-13 (1) X: Current (A) Y: Millions of operating cycles (1) DC-13: switching electromagnets, L/R ≤ (Ue x Ie) in ms, Ue: rated operational voltage, Ie: rated operational current (with a protection diode on the load, DC-12 curves must be used with a coefficient of 0.9 applied to the number in millions of operating cycles). SR3XT43BD 5 ...

Related keywords