ZB5AZ1014 SQUARE D, ZB5AZ1014 Datasheet

no-image

ZB5AZ1014

Manufacturer Part Number
ZB5AZ1014
Description
CONNECT TERMINAL
Manufacturer
SQUARE D
Datasheet
Product data sheet
Characteristics
Complementary
Mar 31, 2012
CAD overall width
CAD overall height
CAD overall depth
Terminals description ISO n°1
Product weight
Additional information
Contacts usage
Positive opening
Operating travel
Operating force
Operating torque
Mechanical durability
Contacts material
Short circuit protection
[Ith] conventional free air thermal current
[Ui] rated insulation voltage
[Uimp] rated impulse withstand voltage
[Ie] rated operational current
Electrical durability
Electrical reliability IEC 60947-5-4
ZB5AZ1014
single contact block with body/fixing collar 1NO
plug-in connector
Main
Range of product
Product or component
type
Device short name
Fixing collar material
Sale per indivisible
quantity
Contacts type and com-
position
Contacts operation
Contact block type
Connections - terminals
30 mm
42 mm
32 mm
(13-14)NO
0.018 kg
With body/fixing collar
Standard contacts
Without positive opening
2.6 mm (NO changing electrical state)
4.3 mm (total travel)
2.3 N (NO changing electrical state)
0.05 N.m (NO changing electrical state)
5000000 cycles
Silver alloy (Ag/Ni)
4 A cartridge fuse type gG conforming to EN/IEC 60947-5-1
10 A conforming to EN/IEC 60947-5-1
250 V (degree of pollution: 3) conforming to EN 60947-1
4 kV conforming to EN 60947-1
6 A at 120 V, AC-15, A300 conforming to EN/IEC 60947-5-1
0.22 A at 125 V, DC-13, R300 conforming to EN/IEC 60947-5-1
0.1 A at 250 V, DC-13, R300 conforming to EN/IEC 60947-5-1
3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1
1000000 cycles, AC-15, 3 A at 24 V, operating rate: 3600 cyc/h, load factor: 0.5
conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.15 A at 110 V, operating rate: 3600 cyc/h, load factor:
0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 1 A at 230 V, operating rate: 3600 cyc/h, load factor: 0.5
conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.4 A at 24 V, operating rate: 3600 cyc/h, load factor: 0.5
conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 1.5 A at 120 V, operating rate: 3600 cyc/h, load factor:
0.5 conforming to EN/IEC 60947-5-1 appendix C
Λ < 10exp(-6) at 5 V, 1 mA in clean environment conforming to EN/IEC
60947-5-4
Λ < 10exp(-8) at 17 V, 5 mA in clean environment conforming to EN/IEC
60947-5-4
Harmony XB5
Complete body/contact assembly
ZB5
Plastic
1
1 NO
Slow-break
Single
Plug-in connector
1

Related parts for ZB5AZ1014

ZB5AZ1014 Summary of contents

Page 1

... Electrical durability Electrical reliability IEC 60947-5-4 Mar 31, 2012 ZB5AZ1014 single contact block with body/fixing collar 1NO plug-in connector Main Range of product Harmony XB5 Product or component ...

Page 2

Environment Protective treatment Ambient air temperature for storage Ambient air temperature for operation IP degree of protection Standards Product certifications Vibration resistance Shock resistance 2 TH -40...70 °C -25...70 °C IP20 conforming to IEC 60529 EN/IEC 60947-5-1 UL 508 EN/IEC ...

Page 3

... Dimensions of Bodies for Pushbuttons and Switches Screw Clamp Terminal Connections ZB5 AZ10•, ZB5 AZ141 Spring Terminal Connections ZB5 AZ10•5 Plug-in Connector ZB5 AZ10•4, ZB5 AZ1414 High Power Switching with Screw Clamp Terminal Connections ZB5 50• block + ZB5 AZ009 body ZB5AZ1014 3 ...

Page 4

... By Faston connectors On printed circuit board Detail of Lug Recess (1) Diameter on finished panel or support (2) For selector switches and Emergency stop buttons, use of an anti-rotation plate type ZB5 AZ902 is recommended. (3) +0.4 Ø22.5 mm recommended (Ø22 Ø0.89 in. recommended (Ø0.88 in ZB5AZ1014 +0.016 ) ...