89750147 Crouzet USA, 89750147 Datasheet

no-image

89750147

Manufacturer Part Number
89750147
Description
STAINLESS SLEEVE-MILL TEMP PRB
Manufacturer
Crouzet USA
Datasheet

Specifications of 89750147

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Control
Catalogue

Related parts for 89750147

89750147 Summary of contents

Page 1

Control Catalogue ...

Page 2

The which does Sensors Sensors Our in-depth knowledge of your business combined with our unrivalled expertise ensure that you benefit from an innovative range of customised products. more for you Control Control Motors Motors ...

Page 3

Control Contents Crouzet, the Control specialist How to order ............................................................................................................................06 The Crouzet offer ....................................................................................................................07 Logic controllers .......................................................................................................... DIN rail mounted timers Panel mounted timers Control relays .............................................................................................................. Solid state relays .......................................................................................................... Solid state I/O modules Temperature controllers................................................................................................ Counters and ratemeters.............................................................................................. ...

Page 4

A brand which sets the standard acknowledged An specialist With 30 years’ experience and extensive technical and industrial expertise, Crouzet is a key player in the Control market. Already world leader in time management functions and management of physical values, ...

Page 5

A brand from the crowd Crouzet is able to approach each project as a true specialist, going beyond a simple product response to offer you a complete solution. Our extensive range of unique products and unmatched expertise ...

Page 6

To order See back page for details of your local Crouzet office Standard products, not in stock • Give the reference in black and Warning: The technical information in this catalogue is given for information only and does not constitute ...

Page 7

... Pneumatic Electro-pneumatic miniature control valves, Intrinsically safe miniature solenoid valves, Multi-fluid solenoid valves, Position detectors, Man / Machine Interface components, Pressure switches and amplifiers, Pneumatic logic components, Vacuum handling components products Senior For more information www.crouzet.com offer www.crouzet.com/OLC To meet your maintenance requirements, the senior products site contains a selection of products which no longer appear in this catalogue ...

Page 8

For more information www.crouzet.com ...

Page 9

Logic controller Logic controller www.crouzet.com 1 9 ...

Page 10

Selection guide Inputs Outputs 4 relays PNP (4 analogue) 4 solid state digital/PWM 0 relays 8 NPN (2 analogue relays PNP (8 analogue) 8 solid state digital/PWM 0.7 ...

Page 11

Adjacent extensions Inputs Outputs 2 relays 4 PNP NPN 2 relays VDC AS-i exchange unit 24 VDC MODBUS exchange unit ➜ Local extensions M2-M2 local link (2 modules) 4 Digital/PWM solid state outputs ...

Page 12

Millenium II +: general characteristics ➜ Starter kit ➜ Special starter kits ➜ Level detection ➜ Standard ➜ Expandable Insulation Safety class Earthing Protection 1 Certifications Conformity to standards Programming method Program size Program memory Removable memory Data memory LCD ...

Page 13

V DC input Input voltage Input current Input impedance Pull-in voltage at logic state 1 Drop-out voltage at logic state 0 Response time Sensor type Galvanic isolation Status indicator Analogue input ( model only) CN12 - SA12 ...

Page 14

Millenium II + ➜ Starter kit ■ Discover the benefits of Millenium II+ ■ Each kit includes : - a standard or expandable Millenium II PC/Millenium progrmming cable - an interactive CD-Rom including the software workshop, tutorial, application ...

Page 15

Millenium II + ➜ Level detection ■ Intuitive programming via function block (FBD) or grafcet (SFC) ■ Function : timing, counting, etc ■ Application-specific functions : rotation, cam timers, calculation, etc ■ Discrete, analogue or potentiometer inputs ■ Relay, solid ...

Page 16

Millenium II + ➜ Standard ■ Intuitive programming via function block (FBD) or grafcet (SFC) ■ Function : timing, counting, etc ■ Application-specific functions : rotation, cam timers, calculation, etc ■ Discrete, analogue or potentiometer inputs ■ Relay, solid state ...

Page 17

Millenium II + ➜ Expandable ■ Expandable : communication, inputs/outputs, etc ■ Intuitive programming via function block (FBD) or grafcet (SFC) ■ Function : timing, counting, etc ■ Application-specific functions : rotation, cam timers, calculation, etc ■ Discrete, analogue or ...

Page 18

Millenium II + ➜ Blind ■ No display or parameter-setting buttons ■ Intuitive programming via function block (FBD) or grafcet (SFC) ■ Function : timing, counting, etc ■ Application-specific functions : rotation, cam timers, calculation, etc ■ Discrete, analogue or ...

Page 19

Millenium II + ➜ Bare board ■ For mass-production applications ■ Intuitive programming via function block (FBD) or grafcet (SFC) ■ Function : timing, counting, etc ■ Application-specific functions : rotation, cam timers, calculation, etc ■ Discrete, analogue or potentiometer ...

Page 20

Millenium II + ➜ Local extensions ■ For XT 20 only (1 local extension per module) ■ Millenium - Millenium local link ■ Doubles the hardware and software capacities ■ Transparent communication between two XT 20 units ■ Max. distance ...

Page 21

Millenium II + ➜ Communication modules ■ For XT 20 only (one adjacent extension per module) ■ Communication using MODBUS or AS-i protocol (Slave module) Specifications Type Designation XC 02 AS-i communication module MODBUS communication ...

Page 22

Modular power supply ➜ Power supply ■ The output voltage can be adjusted from 100 to 120 % with a potentiometer in order to compensate for possible voltage drops. ■ Output voltage existance is indicated by a continuously lit LED. ...

Page 23

Accessories ➜ Front panel adaptors Specifications Type Designation Front panel adaptor Front panel adaptor for EC12-SA12 Front panel adaptor for EC20-SA20-XT20-EX20 Waterproof panel Waterproof panel adaptor for SA12-EC12 Waterproof panel adaptor for SA20-XT20-EC20-EX20 Waterproof panel adaptor for SA20-XT20-EC20-EX20 + 1 ...

Page 24

Temperature sensors ➜ Temperature sensors ■ Built-in converter : 0- output ■ Applications : Industrial and domestic Specifications 1 Type Range Zone -10 Ventilation duct -10 Outdoor -10 Remote/submersible probe -10 Outdoor -40 Accessories Accessories Copper protective sleeve ...

Page 25

Dimensions 89 750 150 Ø3 mm for screw Cut-outs D Fixing holes E Bolt hole M3 F Maximum thickness 750 152 Accessories for 89 750 153 and 89 750 ...

Page 26

For more information www.crouzet.com ...

Page 27

DIN rail-mounted DIN rail-mounted Timers Timers www.crouzet.com 2 27 ...

Page 28

Selection guide Function Delay on energisation (A) • Timing on impulse (one shot) • (B) Timing after impulse • Off-delay timer (C) Timing on energisation (H) • Delay on de-energisation • True delay off (K) 2 Starting “Star-Delta” (Q) • ...

Page 29

Function Casing 17.5 mm Delay on energisation (A) • Delay on energisation with • memory (At) Timing on impulse (one shot) • Shaping (B) Timing after impulse • 22.5 mm Off-delay timer (C) Timing on energisation (H) • Timing on ...

Page 30

Function Timing (to be Voltage Connection specified when ordering) 12 VDC 24 VAC Faston 60 min 48 VAC connectors 6.35 mm 110 VAC 220-240 VAC ...

Page 31

Timing Function specified when ordering wire) 60 min Hp (2 wire) 100 wire) 60 min Hi (4 wire) 60 min H (3 wire) 100 wire) 60 ...

Page 32

Function Frost formation monitored by temperature probe Choice of defrosting time Function Output Timing min 2 2-3-4 1 relay 6 min Heat exchanger defrost relay for air conditioning system Timing max. Voltage ...

Page 33

Basic principles Timers A timer is a control component which, after a preset time, energises an output contact. The start of a timing cycle, single or repetitive, is produced by timer energisation or by maintained or pulse control contacts with, ...

Page 34

... Relay R returns to its initial position at the R2 Inst. end of the timing period. 1 relais ➜ Function Repetitive cycle which switches the output T T alternately between the rest and operating position for equal time bases total Function D: the cycle begins with the output in rest position. Pause start. ...

Page 35

Function Ht : Delay on energisation with memory Provides a cumulative time for contact opening. On energisation, the output changes state, remains in that state for the duration of timing and resets at the end of the single cycle. ...

Page 36

Chronos 2 timers ➜ 17.5 mm DIN rail mounting ■ Relay or solid state output ■ Multi-function or mono-function ■ Multi-range ■ Multi-voltage ■ Screw or spring terminals ■ LED status indicator (relay version) ■ Option of connecting an external ...

Page 37

Dimensions 17,5 3 5,5 Curves Function Delay on energisation Function R1/R2 R2 Inst Flashing single cycle by switch (non resettable) 1 relay Function ...

Page 38

Chronos 2 timers ➜ 22.5 mm DIN rail mounting ■ Multi-function or mono-function ■ Multi-range ■ Multi-voltage ■ Screw or spring terminals ■ LED status indicator ■ Option of connecting an external power supply to the control input ■ 3-wire ...

Page 39

Dimensions 32 63 22,5 3 Curves Function Delay on energisation Function R1/ Inst. Timing after closing and opening of control contact 2 ...

Page 40

Function Timing on energisation 1 relay output Function R1/ Inst t1+t2 Delay on energisation with memory with 2 timed outputs or 1 timed and 1 instantaneous Function Li ...

Page 41

For more information www.crouzet.com 2 41 ...

Page 42

Chronos 2 timers ➜ Plug-in ■ Multi-function or mono-function ■ Multi-range ■ Multi-voltage ■ Relay output 250 V (10 A UL) ■ LED status indicator ■ Option of connecting an external power supply ...

Page 43

Dimensions 74,5 35 3,5 12,5 Curves Function Delay on energisation 1 relay output Function Timing after closing and opening of control contact 1 relay output Function R1/R2 ...

Page 44

Function H U R1/ Inst. Timing on energisation 2 timers or 2 relays, including 1 instantaneous Function Asymmetrical recycler 1 relay Pause start Function Li U R1/ Asymmetrical recycler 1 relay ...

Page 45

Chronos 2 timers: general characteristics ➜ 17.5 mm ➜ 22.5 mm ➜ Plug-in Timing Repetition accuracy with constant ± 0.5 % (IEC 1812-1) parameters Temperature drift ± 0. °C Voltage drift ± 0 Display accuracy ...

Page 46

RTM miniature timers ➜ Plug-IN ■ Miniature plug-in timer ( mm) ■ Function A : Delay on energisation ■ Multi-range 0 ■ Excellent noise resistance ■ Relay output changeover contacts Specifications ...

Page 47

General characteristics Timing ranges Display accuracy Repetition accuracy (with constant parameters) Drift Temperature Drift Voltage Maximum reset time by de-energisation during timed delay Maximum reset time by de-energisation after timing Operating range Frequency (Hz) Immunity from micro power cuts : ...

Page 48

Dimensions Base for DIN rail mounting RTMA2 - 26 532 707 30 24 Base for DIN rail mounting RTMA4 - 26 532 706 2 PCB base RTMA2 26 532 709 21,5 5 11,5 13,5 RTMA2 - RTMA4 3 ...

Page 49

For more information www.crouzet.com 2 49 ...

Page 50

S/SE timers ➜ Delay on energisation Solid state output ■ Mono-function ■ Mono-range-timing fixed, or adjustable by external or built-in potentiometer ■ Mono-voltage ■ Solid state output 0 °C ■ Versions : wire ■ ...

Page 51

Connections SAS SAIS Curves Function A Function Ai To order, see page 6. Accessories, dimensions, function and use, Other information, see page 61. For more information www.crouzet.com SASP Function Ap SASD Function ...

Page 52

S/SE timers ➜ Timing on impulse, one shot Solid state output ■ Mono-range-timing fixed, or adjustable by external or built-in potentiometer ■ Mono-voltage ■ Solid state output 0 °C ■ Versions : wire ■ ...

Page 53

S/SE timers ➜ Timing after impulse Solid state output ■ Mono-range-timing fixed, or adjustable by external or built-in potentiometer ■ Mono-voltage ■ Solid state output 0 °C ■ Versions : wire ■ Fully sealed ...

Page 54

S/SE timers ➜ Timing on energisation Solid state output ■ Mono-funtion ■ Mono-range-timing fixed, or adjustable by external or built-in potentiometer ■ Mono-voltage ■ Solid state output 0 °C ■ Versions : wire ■ ...

Page 55

Curves Function Hb Function Hi Connections SHSB SHIS SHSD To order, see page 6. Accessories, dimensions, function and use, Other information, see page 61. For more information www.crouzet.com Function Hp Function H SHSBP SHS ~ ...

Page 56

S/SE timers ➜ Cyclic timing functions Solid state output ■ Mono-funtion ■ Mono-range-timing fixed, or adjustable by external or built-in potentiometer ■ Mono-voltage ■ Solid state output 0 °C ■ Fully sealed for protection by encapsulation in ...

Page 57

Connections SDSB SDS1A or 2A Curves Function E Function E1 To order, see page 6. Accessories, dimensions, function and use, Other information, see page 61. For more information www.crouzet.com SDSBP Function Ep Function E2 SDSBD Function ...

Page 58

S/SE timers ➜ Fixed cyclic timing Solid state output ■ Mono-funtion ■ Mono-range-timing fixed ■ Mono-voltage ■ Solid state output 0 °C ■ Percentage timer ■ Fully sealed for protection by encapsulation in polyurethane resin ■ Connection ...

Page 59

S/SE timers ➜ Percentage timer Solid state output ■ Mono-funtion ■ Mono-range-timing fixed ■ Mono-voltage ■ Solid state output 0 °C ■ Percentage timer ■ Fully sealed for protection by encapsulation in polyurethane resin ■ Connection by ...

Page 60

S/SE timers ➜ Compressor timer Solid state output ■ Mono-funtion ■ Mono-range-timing fixed ■ Mono-voltage ■ Solid state output 0 °C ■ Specially suitable for compressors and heat pumps ■ Fully sealed for protection by encapsulation in ...

Page 61

Accessories TRPe compatible potentiometer for remote setting of timing period Dimensions Mounting on symmetrical DIN rail EN 50022 Function and use Protection against voltage surge Temperature limit operation (°C) Temperature limits stored (°C) Insulation according to standard VDE 0110 group ...

Page 62

Defrost relay for air conditioning and industrial refrigeration ➜ NFR ■ Frost formation monitored by tamperature probe. ■ Choice of defrosting time. Specifications Type NFR 2 General characteristics Supply voltage Maximum frequency variations Choice of total compressor operating time before ...

Page 63

Connections Principles S1 S2 +18˚C -3˚ OFF T= t1 ...

Page 64

DIN rail mounted ➜ TOP 2000 ■ Multi-function ■ Multi-range ■ Mono-voltage ■ 1 timed changeover + 1 instantaneous contact ■ Elapsed time can be saved mechanically in the event of a break in supply ■ Progress of a cycle ...

Page 65

General characteristics Precision Precision limit error Repetition accuracy Reset time Output specification Timed two-pole Instantaneous single pole Thermal rating Rating (cos ϕ = 0.41 operations Function and use Voltage variation at maximum temperature of 55 100 Absorbed power-motor ...

Page 66

Standards and approvals Our timers are designed according to international recommendations (IEC), American (UL), Canadian (CSA) and German (VDE) standards, European standards (EN), etc. Proof of compliance with these standards and recommendations is demonstrated by approval (a symbol or certificate ...

Page 67

Panel mounted Panel mounted Timers Timers www.crouzet.com 3 67 ...

Page 68

Selection guide Function Output 12 to 240 VDC 24 to 240 VAC 2 relays 24 VAC/DC 220 to 240 VAC A 100 to 240 VAC/DC Solid state 12 to 240 VDC A-B-C-W- 2 relays G-Ac- 240 VAC 3 ...

Page 69

Function Output Voltage 1 relay A 2 relays 127 VAC / 230 VAC 3 relays Function Output Voltage 24 VAC VAC 2-3-4 1 relay 110 to 127 VAC 220 to 240 VAC For more information www.crouzet.com Panel-mounted ...

Page 70

Basic principles Timers A timer is a control component which, after a preset time, energises an output contact. The start of a timing cycle, single or repetitive, is produced by timer energisation or by maintained or pulse control contacts with, ...

Page 71

Standards and approvals Our timers are designed according to international recommendations (IEC), American (UL), Canadian (CSA) and German (VDE) standards, European standards (EN), etc. Proof of compliance with these standards and recommendations is demonstrated by approval (a symbol or certificate ...

Page 72

... T Relay R returns to its initial position at the R2 Inst. end of the timing period. 1 relais ➜ Function Repetitive cycle which switches the output alternately between the rest and operating position for equal time bases total Function D: the cycle begins with the output in rest position. Pause start. ...

Page 73

Function Ht : Delay on energisation with memory Provides a cumulative time for contact opening. On energisation, the output changes state, remains in that state for the duration of timing and resets at the end of the single cycle. ...

Page 74

Analogue TMR 48 ➜ TMR 48 ■ Multi-function or mono-function ■ Multi-range from 0. 300 h ■ Multi-voltage 12 to 240 VDC / 24 to 240 V AC ■ Time setting displayed on dial ■ 2 changeover relays ...

Page 75

Dimensions TMR 6,8 64,5 15,5 96,8 48 Connector base - 25 622 080 - 25 622 130 18 1,1 6,4 ...

Page 76

Function Q2 Star-delta Function A (TMR 48 U) Delay on energisation Start ...

Page 77

For more information www.crouzet.com 3 77 ...

Page 78

TOP 948 digital timers ➜ TOP 948 Relay output digital timer ■ Multi-voltage (voltage range) ■ 1 changeover relay ■ Elapsed time can be saved in the event of a break in supply ■ Optional locking via keyboard of Reset ...

Page 79

General characteristics Display Number of digits Height of digits Precision Timing ranges (7 programmable ranges) Repetition accuracy (even with variation of temperature start T ON Display accuracy Reset time by de-energisation Reset time by control contact Reset time ...

Page 80

Curves Function A Delay on energisation 2-10 2-10 2-5 2-5 2-7 2 without memory C with memory Function B Timing on impulse (one shot) 2-10 2-10 2-5 2-5 2-7 2 ...

Page 81

For more information www.crouzet.com 3 81 ...

Page 82

Relay output digital timer ■ Multi-range ■ Multi-voltage ■ relay outputs ■ Reset function on panel (Timers 815) ■ Data saved in the event of a ...

Page 83

General characteristics Display Number of digits Height of digits Precision Timing ranges Repetition accuracy (with constant parameters) Display accuracy Min. control pulse Maximum reset time by de-energisation during timed delay Maximum reset time by de-energisation after timing Output specification Nominal ...

Page 84

Dimensions 9,7 74,2 16 11-pole rear base 79 694 002 Panel-mounted Panel cut-out VALID MODE 48 8-pin or 11-pin solder connected plug 25 622 301 - 25 622 076 35 ...

Page 85

Connections Timer 812 - 11-pin 2-7 Supply 1-3-4 Timed output contact 8-5-6 Timed output contact Timer 814 - 8 pin ~ + U Start Other loads may be connected ...

Page 86

Relay output ■ Multi-range ■ Multi-voltage ■ 1 relay output ■ Access to programming locked ■ down timing mode ■ Internal power supply by battery (10 years / 20°C) Specifications Type Functions Timer ...

Page 87

General characteristics Display Number of digits Height of digits Precision Timing ranges Repetition accuracy (with constant parameters) Display accuracy Min. control pulse Maximum reset time by de-energisation during timed delay Maximum reset time by de-energisation after timing Output specification Nominal ...

Page 88

Dimensions 9,7 74,2 16 11-pole rear base79 694 002Panel-mounted Connector socket11-pin 25 622 077 8-pin 25 622 128 88 Panel cut-out VALID MODE 48 8-pin or 11-pin solder-connected plug 25 622 076 - 25 622 ...

Page 89

For more information www.crouzet.com 3 89 ...

Page 90

MBA Ø 22 panel-mounted timers ➜ MBA Solid state output ■ Panel-mounted pushbutton-type timer ■ Function A delay on energisation ■ 10 timing ranges : 0. min ■ ➞ Supply and 110 240 V ...

Page 91

Dimensions 14 47,5 B Panel C Nut D Sealing ring Connections Version 110 - 240 (+) (-) (+) (-) B Load For more ...

Page 92

Panel-mounted electromechanical timers ➜ Top 2000 Relay output ■ Mono-voltage ■ 1 timed changeover and 1 instantaneous contact ■ Elapsed time can be saved mechanically in the event of a break in supply ■ Progress of cycle displayed ■ Housing ...

Page 93

General characteristics Precision Precision limit error Repetition accuracy Selection precision Reset time Output specification Timed two-pole Instantaneous single pole Thermal rating Rating (cos ϕ = 0.41 operations Function and use Absorbed power--motor Voltage variation at maximum temperature of ...

Page 94

Connections Function Internal layout 88 226 0 Terminal identification 88 226 5 3 2-7 Supply 8-5-6 Timed contact 3-1 Instantaneous contact 94 Function ...

Page 95

For more information www.crouzet.com 3 95 ...

Page 96

Panel-mounted electromechanical timers ➜ Manual reset Relay output ■ Mono-function ■ Mono-range ■ Mono-voltage ■ Manual reset ■ Progress of cycle displayed ■ Output : 1 changeover contacts (max per contact) ■ Mounting option Specifications ...

Page 97

Dimensions Panel cut-out 88 256 256 83 256 Connections 1 pole Red C Blue D White 1 ...

Page 98

For more information www.crouzet.com ...

Page 99

Control relays Control relays www.crouzet.com 4 99 ...

Page 100

For more information www.crouzet.com ...

Page 101

Selection guide Control function • Loss or inversion of one of the phases • Total phase failure • Phase sequence • Voltage drop on one or more phases • Total phase failure • Phase sequence • Voltage drop on one ...

Page 102

Control function Measurement range ALTERNATING current With current transformer 2 to 500 mA DIRECT current 2 to 500 mA ALTERNATING and DIRECT current 4 ➜ Motor LOAD control relay (Cos. Control function Controlling motor under/overload by measuring the phase shift ...

Page 103

Control function Sensitivity Filling OR emptying LOW sensitivity 250 with timing NORMAL sensitivity levels: high/low) HIGH sensitivity 50 k Without alarm Sensitivity 5 k Filling OR emptying (2 levels: high/low) With alarm (Overflow or running ...

Page 104

Level control ➜ ENR filling or emptying function ■ Regulation of two levels (min./max.) ■ Monitoring filling (UP) or emptying (DOWN) , selected by a switch on the front panel. ■ Probes supplied with AC current. ■ Sensitivity adjustable on ...

Page 105

Principles Principles Monitoring filling or emptying ENR Monitoring filling or emptying ENR Down Maximum level Maximum level C Minimum level Minimum level D Output relay : Down or Up Output relay : Down ...

Page 106

Level control ➜ ENRM filling or emptying with adjustable time delay ■ Regulation of one or two levels (min./max.) ■ Monitoring filling (UP) or emptying (DOWN) selected by a switch on the front panel. ■ Probes supplied with AC current. ...

Page 107

Connections Adjusting two levels Monitoring filling "Up" Min Max Max. 3 Min Common C Off Output A1-A2 : ...

Page 108

Rotary switch in mode 3 - Deactivation time - Filling function Level C Relay Rotary switch in mode 3 - Deactivation time - Emptying function Level ...

Page 109

For more information www.crouzet.com 4 109 ...

Page 110

Level control ➜ LN plug-in emptying function ■ Relay for controlling level of conductive liquids ■ Regulation of two levels : - minimum - maximum ■ Empty function ■ Plug pins) ■ Sensitivity adjustable from 5 ...

Page 111

Connections Max. Min Principles Emptying control ...

Page 112

Level control ➜ L2N plug-in filling/emptying function ■ Relay for controlling level of conductive liquids ■ Combined fill and empty functions ■ Combined regulation of pumping out a well and filling a tank ■ Plug in (11 pins) ■ Output ...

Page 113

Principles Emptying control Max. 2 Min. Max. 3 Min Push button C Well D Tank E Output relay For more information www.crouzet.com Operating principle Control of maximum and/or minimum levels of conductive liquids ...

Page 114

Level control ➜ F2N filling/emptying function ■ Control and automatic regulation of liquid levels. ■ Sensitivity adjustement from 5 to 100 kΩ. ■ Combined regulation : emptying a well and filling a tank ■ LEDs indicate power supply and state ...

Page 115

Dimensions F2N 3 100 Connections F2N Min Max Min. Max Max. 2 Min Principles Un ...

Page 116

Level control ➜ FN filling/emptying function with alarm ■ Automatic control and regulation of liquid levels. ■ 2 sensitivity ranges. ■ Filling or emptying function selected via dip switch. ■ High or low alarm selected via dip switch. ■ Memory ...

Page 117

Dimensions 3 100 Connections Regulating with "up" filling control Min. Max Principles Filling control ...

Page 118

... To reset alarm relay R2, cut the power, as long as the levels are reset. Programming The FN level controller can be programmed using 3 switches on the lower panel : Note : Memory, Alarm and Function must only be selected when the unit is switched off. ...

Page 119

Level control ➜ Electrode holders and level probes ■ Accessories for level control Specifications Type Accessories S8 A light, compact, 3-probe electrode holder (stainless steel). Electrode holder and 1000 mm probe. Particularly recommended for drinks vending machines and in cases ...

Page 120

Phase control ➜ EWS / EWS2 phase sequence and loss of phase ■ Space savings, accurate measurement and optimized functions all improve the efficiency of your electrical installation. ■ Control : You simply install your EWS phase control relay and ...

Page 121

Connections EWS EWS2 Principles Timing diagrams EWS Phase L1 ...

Page 122

Phase control ➜ EW2 / EWA2 phase asymmetry, sequence, loss or volt drop ■ Control : - imbalance (asymmetry) between phases (for EWA2) - phase sequence - phase failure - voltage drop on one or more phases ■ Asymmetry rate ...

Page 123

Dimensions EW2 Connections EW2 EW2 Principles EW2 / EWA2 100 100 100 ...

Page 124

Phase control ➜ FW phase sequence, loss or volt drop ■ Controls : - phase sequence - loss of one or more phases - undervoltage ■ Control power from sensed circuit ■ Potentiometer for adjusting network voltage ■ Time delay ...

Page 125

Dimensions FW 3 100 Connections Isolating switch C Contactor D ...

Page 126

Phase control ➜ FWA/FWA2 phase asymmetry self-powered ■ Controls : - imbalance (asymmetry) between phases, - phase sequencing - loss of phase with regeneration Un. ■ Asymmetry rate adjustable on front face ( ...

Page 127

General characteristics Technical specifications Auxiliary power supply Auxiliary voltage (self powered from terminals L1 and L2) Operating range Frequency (Hz) Consumption Immunity from micro power cuts Delay on power-up T3 Delay on power-down T2 Insulation coordination Input circuit 3-phase network ...

Page 128

Connections FWA/FWA2 FWA/FWA2 Isolating switch C Alarm 128 FWA/FWA2 ...

Page 129

For more information www.crouzet.com 4 129 ...

Page 130

Control with LCD display - Voltage - Current ➜ HDU / HDI ■ Displays the current value and the preset value on LCD ■ Controls AC and DC signals (automatic detection) ■ Selectable overload or underload mode ■ Threshold and ...

Page 131

General characteristics Supply Supply voltage Operating range Maximum power consumption Immunity from micro power cuts Delay on pick-up Insulation coordination Output circuit Output Minimum current Mechanical life (operations) Maximum rate Electrical life (A) General characteristics Delay on threshold crossing Display ...

Page 132

Connections HDI / HDU (+) (+) (+) U >< A2 M(-) HDI (+) (-) ...

Page 133

... The threshold and hysteresis can be adjusted separately via two potentiometers on the front face. Before powering up the device, the operating mode should be selected using two dipswitches located under the device (with/without memory, over/under value). The mode is validated when power is applied to terminals A1 - A2. ...

Page 134

Current control ➜ MCI AC current control ■ Current transformer fitted by passing a cable through the front ■ AC current threshold adjustable from ( 400 Hz) via button on front ■ Relay ...

Page 135

Dimensions MCI 17,5 Ø 5,5 16,8 43,7 5 82,2 Connections MCI U (+) (-) Power supply 110...240 VAC Power supply 240 VAC Principles MCI ...

Page 136

Current control ➜ EI AC/DC current control ■ Space savings, accurate measurement and optimized functions all improve the efficiency of your electrical installation. ■ Control : Select ’’Over-current’’ or ’’Under-current’’ control mode, by means of a dip switch on the ...

Page 137

Dimensions EIL / EIH / EIT 32 63 22,5 3 Connections EIL / EIH U (+) (+) (+) (+) (-) (-) ...

Page 138

Voltage control ➜ EUL/EUH AC/DC voltage control ■ Voltage monitoring ■ 2 relays to cover 6 ranges of measurement : 0.2V to 600V ■ Automatic recognition AC/DC ■ Frequency up to 500 Hz Specifications Supply voltage ...

Page 139

Connections EUL U (+) (+) (+) (+) (-) (-) Supply voltage Principles Control of AC/DC voltage without memory ...

Page 140

Voltage control ➜ EUS/EUSF AC/DC voltage control with memory function ■ Control their own supply ■ Automatically detect the signal ■ EUS for the control of over/under voltage (selectable) ■ EUSF for the control between 2 values ...

Page 141

... T1 which can be set on the front face at between 0.1 and 3s. It switches back on when the voltage returns within the window and stays between the upper and lower thresholds displayed by two potentiometers on the front face. Fixed hysteresis ensures bounce-free relay switching around the threshold ...

Page 142

Voltage control ➜ F3US / F3USN 3-phase voltage control ■ Controls over- and undervoltages on own power supply (window-type). ■ F3US : phase-to-phase / F3USN : phase and neutral. ■ Minimum and maximum thresholds can be adjusted separately ■ Detects ...

Page 143

Dimensions F3US / F3USN 3 100 Connections F3US Auxiliary power supply F3US > < ...

Page 144

Motor control ➜ FFP motor load (cosine ϕ) control ■ Self-powered ■ Controls motor overload and underload ■ Measures the phase shift between the current and the voltage (cosine ϕ) ■ Independent adjustment of min. and max. thresholds from 0.1 ...

Page 145

Dimensions FFP 3 100 Connections FFP Operation on 3-phase network I < 400 Internal shunt L1 ...

Page 146

Motor control ➜ FRL motor underspeed control ■ Control of underspeed, stopping, running speed, or jamming of a motor. ■ Data collected by three-wire or NAMUR sensor contact or voltage ■ Delay adjustable from 100 ...

Page 147

Dimensions FRL 3 100 Principles Without latching Hysteresis C Speed displayed D Output relay E Inhibition delay With latching 200 ms min ...

Page 148

Motor control ➜ ETM / ETM2 / ETM22 motor thermal protection ■ Controls temperature of machines using built-in PTC probes ■ Line break or probe short-circuit detection Version ETM2 / ETM22 : ■ Fault latching function ■ Pushbutton for local ...

Page 149

Dimensions ETM / ETM2 / ETM22 100 Connections ETM U + CTP DIN 44081 ϑ Supply voltage Output relay ...

Page 150

Principles Reset WITHOUT fault latching (Y1 and Y2 not connected for ETM2/ETM22) U 3100 1650 Unit power-up C Resistance between terminals T1 and T2 D Output relay PTC probe specification According to standard DIN 44081 (or ...

Page 151

For more information www.crouzet.com 4 151 ...

Page 152

Variable speed ➜ Single-phase 300 W ■ Control fan speeds in air-conditioning applications ■ For 150 to 300 W asynchronous motor at 230 V AC with permanent dephasing via capacitor ■ control input ■ Quiet Specifications ...

Page 153

General characteristics Technical specifications Supply Voltage Frequency Power consumption Internal protection input Input voltage Max. voltage Input impedance (kΩ) Protection Transfer characteristics Motor control Characteristics of the load Supply Absorbed power cos ϕ Voltage range (RMS) ...

Page 154

Principles Basic controller 1 2 Crouzet controller Curves Operating principle Phase control by modification of the aperture angle of a triac input : Motor control activated when input higher than 2 V ...

Page 155

Solid state relays Solid state relays www.crouzet.com 5 155 ...

Page 156

Selection guide ➜ Solid state relays - resistive and inductive load Mains supply Current Single-phase 100 A ...

Page 157

Mains supply Current* Output voltage 660 V AC Two-phase 280 280 660 ...

Page 158

Relay-heatsink assembly for DIN rail mounting Mains supply Designation GA0 25 A Single-phase GA0 45 A ➜ Solid state relays - RHP Function Current AC control contactor 20 A single-pole DC control contactor 20 A single-pole Day/night contactor 20 ...

Page 159

For more information www.crouzet.com 5 159 ...

Page 160

Hybrid power relays ➜ RHP ■ case only 17.5 mm wide ■ Service life > 5 million operations at full load ■ Silent operation ■ Functions : contactor - impulse relay - day / night contactor ...

Page 161

Connections 90... 260V 90...260 V AC/4... LOAD Principles Operating principles Contactor The contactor output is closed ...

Page 162

GRD single or double phase DIN rail mounting ➜ GRD range 22.5 mm single phase ■ Single phase ■ Complete, compact units ■ Tailor-made solution to current sinks ■ DIN rail and panel mounting ■ Rating : 12 and 25 ...

Page 163

General characteristics Output characteristics Voltage range (Vrms max) Peak voltage - t = min (V) Maximum off-state leakage at Vmax and °C (mAeff per phase) Minimum current mA(rms) per phase Max. 1-cycle surge A(peak) Max. 1-second surge ...

Page 164

GRD single or double phase DIN rail mounting ➜ GRD Range 45 mm single phase ■ Single phase ■ Complete, compact units ■ Tailor-made solution to current sinks ■ DIN rail and panel mounting ■ Rating : 35 and 45 ...

Page 165

Dimensions 35,70 3,20 4,5 Ø 4,5 12,2 6,80 9,30 102,80 45 Connections GRD range - single-phase with SCR Zero voltage switching Curves GRD range ( ...

Page 166

GRD three-phase DIN rail mounting ➜ GRD Range phase ■ Three-phase ■ Complete, compact units ■ Tailor-made solution to current sinks ■ DIN rail and panel mounting ■ Rating : ■ Back-to-back SCRs ...

Page 167

Dimensions 80,70 3,20 4,5 Ø 4,5 12,2 6,80 9,30 90 Connections GRD range - three-phase with SCR A1 A2- Curves GRD range I( ...

Page 168

GRD double phase DIN rail mounting ➜ GRD Range 90 mm double phase ■ Double phase ■ Complete, compact units ■ Tailor-made solution to current sinks ■ DIN rail and panel mounting ■ Rating : ■ ...

Page 169

Dimensions 80,70 3,20 4,5 Ø 4,5 12,2 6,80 9,30 90 Curves GRD range I( (˚ For more information ...

Page 170

GN single-phase ➜ GND DC output ■ FET transistor versions 10, 15 and 30 A ■ Bipolar transistor version 10 A ■ Control voltage : ■ Optimum thermal response ■ Available with or without protective cover ...

Page 171

Dimensions 44,4 (1.75) 27,9 (1.1) 11,9 (0.47) 25,4 (1) Curves GN SSR FET 10 A 10.0 8.0 6.0 1 4.0 2.0 0 1,5 C/W 2.0 ...

Page 172

GN single-phase ➜ GNA5 - Triac output ■ Intented for resistive loads ■ Current ratings 10 and 25 A ■ Output voltage 24 to 280 V AC ■ "Zero voltage" switching ■ Optimum thermal response ■ Control input 3-32 V ...

Page 173

Dimensions 44,4 (1.75) 27,9 (1.1) 11,9 (0.47) 25,4 (1) Curves 10 A 10.0 8.0 6.0 4.0 2.0 0 For more information www.crouzet.com 22,2 (0.875) 19 (0.75) 6,35 ...

Page 174

DUAL two-phase solid state relay ➜ DUAL ■ Rating 2x25A or 2x40A ■ Output voltage 24 to 280 V ■ Back-to-back SCR ■ Instantaneous or zero volt switching ■ Input to output insulation voltage : 4000 V ■ Protection by ...

Page 175

Dimensions B 11,9 (0.47) 7,6 (0.3) 22,5 (0.886) 2,5 (0.1) Connections Equivalent circuits + - + - Curves 50,0 40,0 30,0 20,0 10,0 0 ...

Page 176

GN single-phase ➜ output ■ EMC compatible for industrial environments ■ built-in transient protections ■ Optimum thermal response ■ Regulated control input ■ Control status LED ■ Available with or without protective cover Specifications Current Output voltage 125 ...

Page 177

General characteristics General characteristics Operating temperature ( o C) Storage temperature ( 0 C) Input to output insulation voltage V(rms) Dielectric strength V(rms) Input/output capacitance (pF) Frequency (Hz) Material housing Material baseplate Weight (g) Control specifications Turn-off voltage (V) Max. ...

Page 178

Curves GN 10 AMP SSR (1200 & 600 V) 10,0 8,0 6,0 1 4,0 2,0 0 3,0 C/W 5,0 C/W B Load current (A) C ...

Page 179

GMS single-phase DIN rail mounting ➜ GMS range ■ Complete, compact units ■ DIN rail and panel mounting ■ Input voltage 4- regulated ■ Input to output insulation voltage : 4 Kv ■ LED display of input status ...

Page 180

Relay-heatsink assemblies ➜ DIN rail mounting Specifications Type Relay GA0- 067 441 GA3- 028 451 GA3- 068 451 GA3- 068 453 GA3- 068 651 Current (A) 24 ...

Page 181

For more information www.crouzet.com 5 181 ...

Page 182

PCB-mountable ➜ GA1 and GA8 ■ PCB-mountable (flat pack = GA1, SIP = GA8) ■ Rating : 4 A-5 A ■ Peak voltage : 600 V ■ Will withstand a 1-cycle 100 A surge ■ TRIAC outputs ■ ...

Page 183

Dimensions GA1 35,6 6,4 9,5 3,8 27,9 3 1,0 7,6 20,3 General tolerances ± 0.5 Connections Equivalent circuits Matching and trigger circuit (zero voltage) Curves ...

Page 184

SMART module ➜ Control module for solid state relays ■ Patented operating principle (96 050 16). ■ Provides both visual and electrical information if a fault occurs in the circuit or on the solid state relay being controlled ■ For ...

Page 185

Connections Curves SMART SSR power supply C SSR input D Green LED E Mains presence F Load : closed circuit G ...

Page 186

Low cost solid state relays ➜ GZ range ■ Low-cost solid state relay - Triac output ■ Extra-slim casing ■ Output current 12 and 20 A ■ Output voltages 24-280 V AC and 36-530 V AC ■ Control input 4-15 ...

Page 187

Dimensions 38,1 (1.5) 25,4 (1) Ø 5,05 (0.199) 0.76 (0.03) 12,7 (0.5) Connections Curves 12 A version 12,0 11,0 10,0 9,0 1 8,0 7,0 6,0 5 Current A(rms) C ...

Page 188

GA three-phase ➜ GA0 three-phase changeover ■ Reverses rotation of three-phase motors ■ Output voltage 24-480 V AC ■ Input voltage 3- ■ Input to output insulation voltage : 100 ms ■ Interlock against simultaneous actuation in both ...

Page 189

Dimensions 104 7, 5,3 A1F A2 A1R 12 screw C 3 M3.5 screws Tolérances générales ± 0.5 Connections ...

Page 190

GA three-phase ➜ GA3 three-phase ■ For controlling three-phase loads ■ Rating 10, 25 ■ Output voltages to 660 Vrms ■ Control voltage 4- 90-280 V AC ■ Peak voltage : 1200 V ■ Back-to-back ...

Page 191

Dimensions 104 2 ± 0,2 92 ∅ 5 screws C 2 M3.5 screws Connections Equivalent circuits A1+ 1 A2- B Input C Output For more information www.crouzet.com 191 ...

Page 192

Curves GA3 range - Dissipated power (W) C On-state current (A) D Ambient temperature (°C) E Baseplate temperature (°C) F ...

Page 193

Accessories for solid state relays ® THERMSTRATE heat seal Heat transfer compound “FERRAZ” quick-blow fuses To ensure that the solid state relay is fully protected, we recommend the use of quick-blow fuses. Their role is to protect the solid state ...

Page 194

Accessories for solid state relays Heatsinks 120 15 9 17 10, 112 47,6 7,3 ±0,15 4,4 ±0,2 76,2 87 Adaptors for fixing on panel (set 194 Range Thermal resistance 1 ...

Page 195

Accessories for solid state relays Protective cover 38,48 38,48 6,35 3 Ø 3,9 8,89 R 7,62 R 6,35 6,35 27,34 27,34 73,4 1,78 21,59 11,43 38,48 38,48 3 Ø 3,9 8,89 R 7,62 R 6,35 6,35 28,57 29,54 73,4 1,78 ...

Page 196

For more information www.crouzet.com ...

Page 197

Solid state I/O Solid state I/O modules modules www.crouzet.com 6 197 ...

Page 198

For more information www.crouzet.com ...

Page 199

Selection guide Control Module type Output type voltage Transistor Triac 0.5 A Transistor 0.5 A Transistor Triac 0.5 A Triac changeover relay 24 V AC/DC 1 changeover ...

Page 200

Input and output modules ➜ Input module SImm A range of space-saving modules for isolation of input signals. ■ Only 6.2 mm wide and 65 mm deep. ■ DIN rail mounting. ■ Built-in LED shows the status of the input ...

Related keywords