C200H-COV11 Omron, C200H-COV11 Datasheet

no-image

C200H-COV11

Manufacturer Part Number
C200H-COV11
Description
C200H 5&8-PT. TERM.COVER
Manufacturer
Omron
Datasheet

Specifications of C200H-COV11

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
CS1 Ordering Guide
CPU Selection
J CPU Rack
Note:
Name
CPUs
(See note.)
(
CPU Backplanes
(f
(for CS1 Units only)
CPU Backplanes
Power Supply Units
I/O Control Unit
C--170
CS1 U i
When using a CS1W-CN313 or CS1W-CN713 I/O Connecting Cable with a CS1j-CPUjjH CPU, use only Cables produced on
or after September 20, 2001 (production number 2091). Cables with no production number, or produced before September
20, 2001, cannot be used.
pp y
)
p
p
Programmable Controller
l )
Specifications
I/O bits
5,120
5,120
5,120
5,120
5,120
5,120
1,280
960
960
2 slots (Does not connect to Expansion Rack.)
3 slots
5 slots
8 slots
10 slots
2 slots (Does not connect to Expansion Rack.)
3 slots
5 slots
8 slots
10 slots
100 to 120 VAC or 200 to 240 VAC; Output capacity: 4.6 A, 5 VDC
100 to 120 VAC or 200 to 240 VAC (with 0.8 A, 24 VDC service power
supply)
Output capacity: 4.6 A, 5 VDC
100 to 120 VAC or 200 to 240 VAC (with RUN output) Output capacity:
4.6 A, 5 VDC
100 to 120 VAC or 200 to 240 VAC (with RUN output) Output capacity:
9 A, 5 VDC
24 VDC, Output capacity: 4.6 A, 5 VDC
For Expansion Racks connected over a distance of more than 12 m
(2 terminating resistors included. C200H Modules cannot be used on
Long-distance Expansion Racks.)
Reading the production number
j j j j
Program
capacity
250K steps
120K steps
60K steps
30K steps
20K steps
60K steps
30K steps
20K steps
10K steps
Year (e.g., 1997=7)
Month (1 to 9, X (10), Y (11), Z (12))
Day (01 to 31)
CS1
Data memory capacity
448K words (DM: 32K words, EM: 32K words ×13
banks)
256K words (DM: 32K words, EM: 32K words ×7
banks)
128K words (DM: 32K words, EM: 32K words ×3
banks)
64K words (DM: 32K words, EM: 32K words ×1
bank)
64K words (DM: 32K words, EM: 32K words ×1
bank)
128K words (DM: 32K words, EM: 32K words ×3
banks)
64K words (DM: 32K words, EM: 32K words ×1
bank)
64K words (DM: 32K words, EM: 32K words ×1
bank)
64K words (DM: 32K words, EM: 32K words ×1
bank)
(This table continues on the next page.)
Standards
---
N, L, UC,
CE, CID2
U, C, N, L,
CE
CE
U, C, N, L,
CE
CE
U, C, N, L,
CE
CE
U, C
U, C, N, L,
CE
U, C, N, L,
CE
U, C, CE, N
, , , ,
, , , ,
, , , ,
,
Part number
---
CS1H-CPU67H
CS1H-CPU66H
CS1H-CPU65H
CS1H-CPU64H
CS1H-CPU63H
CS1G-CPU45H
CS1G-CPU44H
CS1G-CPU43H
CS1G-CPU42H
CS1W-BC022
CS1W-BC032
CS1W-BC052
CS1W-BC082
CS1W-BC102
CS1W-BC023
CS1W-BC033
CS1W-BC053
CS1W-BC083
CS1W-BC103
C200HW-PA204
C200HW-PA204S
C200HW-PA204R
C200HW-PA209R
C200HW-PD024
CS1W-IC102

Related parts for C200H-COV11

C200H-COV11 Summary of contents

Page 1

... A, 5 VDC 24 VDC, Output capacity: 4 VDC I/O Control Unit For Expansion Racks connected over a distance of more than terminating resistors included. C200H Modules cannot be used on Long-distance Expansion Racks.) Note: When using a CS1W-CN313 or CS1W-CN713 I/O Connecting Cable with a CS1j-CPUjjH CPU, use only Cables produced on or after September 20, 2001 (production number 2091) ...

Page 2

... Programming Connects the CQM1-PRO01-E Programming Console. (Length: 0.05 m) Console Connecting Console Connecting Cables Connects the C200H-PRO27-E Programming Console. (Length: 2.0 m) Connects the C200H-PRO27-E Programming Console. (Length: 6.0 m) CX-Programmer For 1 license For 3 licenses For 10 licenses Peripheral Device Connects DOS computers, D-Sub 9-pin receptacle (Length: 0.1 m) ...

Page 3

... VDC 100 to 120 VAC or 200 to 240 VAC (with RUN output) Output capacity VDC I/O Interface Unit For Expansion Racks connected over a distance of more than 12 m. (C200H Modules cannot be used on Long-distance Expansion Racks.) CS1 I/O Connecting Cables / g Connects CS1 Expansion I/O Backplanes (See note ...

Page 4

... Connecting Cables CPU Backplanes or CS1 Expansion I/O CPU B Backplanes. Backplanes C200H I/O Connecting / g Connects C200H Expansion I/O Backplanes C bl Cables to other C200H Expansion I/O Backplanes. h C200H E J C200H Basic I/O Modules Mountable Racks Name Specifications p CPU Rack DC Input VDC, Yes Modules ...

Page 5

... Yes put Mod- ules 32 outputs Yes Note: 1. Interrupt Input Modules can only be used to input interrupts on the CPU Rack. They will function as normal I/O Modules on other Racks. 2. C200H-B7A12/02/21/22are C200H Group-2 Modules. C--174 Programmable Controller C200H CS1 CS1 SYSMAC Expansion Expansion Long ...

Page 6

... Interrupt Input Modules can only be used to input interrupts on the CPU Rack. They will function as normal I/O Modules on other Racks. 2. C200H-B7A12/02/21/22are C200H Group-2 Modules. 3. The C200H-ID001 (no-voltage contacts, 8 inputs, NPN) and C200H-ID002 (no-voltage contacts, 8 inputs, PNP) cannot be used. J C200H Group-2 High-density I/O Modules ...

Page 7

... Note: 1. Refer to the XW2j Connector-T erminal Block Conversion Unit catalog for details. (Square boxes indicate the cable length.) 2. The XW2Z-jjjD, CS1W-ODjjj, and C200H-ODjjj cannot be connected. Only the inputs of the CS1W-MDjjj can be connected. J CS1 High-density I/O Modules Mountable Racks Name ...

Page 8

... A, 48 inputs VDC, 0 outputs, sinking inputs/outputs 24 VDC, approx. Yes inputs VDC, 0 outputs, sourcing inputs/outputs Note: Interrupt input is not available when mounted on these Racks (i.e., used as normal I/O Unit). C200H CS1 CS1 SYSMAC Expansion Expansion Long- BUS I/O Racks Racks distance Slave Racks ...

Page 9

... Pressure welded Terminal block 1:1 1:2 1:3 Note: Refer to the XW2j Connector-T erminal Block Conversion Unit catalog for details. (Square boxes indicate the cable length.) J C200H High-density I/O Modules Classified as Special I/O Modules Name Specifications Mountable Racks CPU Rack DC Input Modules ...

Page 10

... J Connectors for C200H High-density I/O Modules Part Connection Applicable Soldered connectors (included with Unit) Crimped Pressure welded Terminal block Special Cable connection parts p Terminal Block Connector Special Cable Terminal Block Connector Note: Refer to the XW2j Connector-T erminal Block Conversion Unit catalog for details. (Square boxes indicate the cable length ...

Page 11

... CS1 Ordering Guide Special I/O Modules J C200H Special I/O Modules Mountable Racks Name Specifications p CPU C200H Rack Expansion I/O Racks Temperature Thermocou- Yes Yes Control Mod- ple input, ules time-propor- tioning PID, or ON/OFF transistor out- put Yes Yes Thermocou- ple input, ...

Page 12

... C200H Special I/O Modules (continued) Mountable Racks Name Specifications p CPU C200H Rack Expansion I/O Racks Heat/Cool Thermocou- Yes Yes Temperature ple input, Control time-propor- Modules tioning PID, or ON/OFF transistor out- put Thermocou- Yes Yes ple input, time-propor- tioning PID, or ON/OFF voltage out- ...

Page 13

... CS1 Ordering Guide Special I/O Modules C200H Special I/O Modules (continued) Mountable Racks Name Specifications p CPU C200H Rack Expansion I/O Racks PID Control Voltage out- Yes Yes Modules put/current input, time- proportioning PID, or ON/ OFF transis- tor output Voltage out- Yes ...

Page 14

... C200H Special I/O Modules (continued) Mountable Racks Name Specifications p CPU C200H Rack Expansion I/O Racks Data Setting Used with --- Console Cam Positioner Unit. Monitoring, setting, and changing present values, set points, alarm values, PID parameters, bank numbers, etc. Connecting --- Cable Connecting ...

Page 15

... CS1 Ordering Guide Special I/O Modules C200H Special I/O Modules (continued) Mountable Racks Name Specifications p CPU C200H Rack Expansion I/O Racks Analog Out mA, 1 Yes Yes put Modules to 5 (selectable); 2 outputs; 1/4,075 reso- lution mA, Yes Yes --10 to +10 V (selectable), 4 outputs; voltage: ...

Page 16

... C200H Special I/O Modules (continued) Mountable Racks Name Specifications p CPU C200H Rack Expansion I/O Racks High-speed One-axis Yes Yes Counter pulse input, Modules counting rate: 50 kcps max. One-axis Yes Yes pulse input, counting rate: 75 kcps max., line driver com- patible Two-axis ...

Page 17

... CS1 Ordering Guide Special I/O Modules C200H Special I/O Modules (continued) Mountable Racks Name Specifications p CPU C200H Rack Expansion I/O Racks Motion Con- G-language Yes Yes trol Modules program- mable, two- axis analog outputs MC Support --- Software IBM PC/AT or compat- ible Connecting --- Cable: 3 ...

Page 18

... C200H Special I/O Modules (continued) Mountable Racks Name Specifications p CPU C200H Rack Expansion I/O Racks Position Peripheral --- Control Mod- Port Con- ules necting Cables for computer RS-232C --- Port Con- necting ti Cables for computer computer 1-axis Relay Unit for C200HW- NC113 2-axis Relay ...

Page 19

... CS1 Ordering Guide Special I/O Modules C200H Special I/O Modules (continued) Mountable Racks Name Specifications p CPU C200H Rack Expansion I/O Racks ID Sensor Electromag- Yes Yes Modules netic cou- pling Microwave Yes Yes type Fuzzy Logic Use with Yes Yes Unit Fuzzy Sup- ...

Page 20

... V, -- mA) Reso- lution: 1/4,000 8 outputs ( -- mA) Reso- lution: 1/4,000 8 outputs ( mA) Resolution: 1/4,000 Analog I/O 4 inputs ( mA Unit 5 V, etc.) 4 outputs ( etc.) C200H CS1 CS1 Long- SYSMAC Expansion Expansion distance BUS Slave I/O Racks Racks Racks Racks No Yes Yes No No Yes Yes No No Yes ...

Page 21

... Input Unit 100 mA, ±100 mV Support Setting tool --- Software software for the Proces- sing I/O Mod- ules, OS: Windows 95, 98, NT 4.0 (see note) C--190 Programmable Controller C200H CS1 CS1 Long- SYSMAC Expansion Expansion distance BUS Slave I/O Racks Racks Racks Racks No Yes Yes No (This table continues on the next page ...

Page 22

... I/O connectors) MC Terminal Block Conversion Unit for 4 Axes (simplifies wiring I/O connectors) MC Terminal Block Conversion Unit Cable Note: Setting tool software for the Processing I/O Modules also supports CS1W-ADjjj, CS1WS-DAjjj, and CS1W-MAD44. C200H CS1 CS1 Long- SYSMAC Expansion Expansion distance BUS Slave ...

Page 23

... CS1 Ordering Guide CPU Bus Modules CS1 CPU Bus Modules (Continued) Mountable Racks Name Specifications p CPU C200H Rack Expansion I/O Racks Controller Twisted pair Yes Link Mod- Optical ring Yes No ules (H-PCF cable) Optical ring Yes No (GI cable) Controller For PCI Bus ...

Page 24

... Available in Canada only. Words allocated CS1 CS1 SYSMAC (CIO 1500 Expansion Long- BUS to Racks distance Slave CIO 1899) Racks Racks --- --- --- --- --- --- --- Programmable Controller CS1 Ordering Guide CPU Bus Modules Unit Standards Part number N No. --- --- WS02-LCTC1-E --- --- WS02-LCTK1-EL01 CE --- CS1W-CN118 --- CS1W-CN226 --- CS1W-CN626 --- --- C200H-CN229-EU CBL-202* --- --- CS1W-C1F31 CS1 C--193 ...

Page 25

... Provides CompoBus/S Master. I/O Link Modules 512 internal inputs/512 internal outputs (between CS1 or C200HX/HG/HE PLC and Master) 16 internal inputs/16 internal outputs (between CQM1/CQM1H PLC and Master) 32 internal inputs/32 internal outputs (between CPM1A/CPM2A PLC and Master) Remote Transistor I/O Terminals / ...

Page 26

DeviceNet Slaves (continued) Slave Specifications Remote Common power p 16 input points (NPN with + common) Transistor T i supply for input points (PNP with -- common) I/O Terminals I/O Terminals communications and communications and 8 input ...

Page 27

CS1 Ordering Guide DeviceNet Slaves DeviceNet Slaves (continued) Slave Specifications Water-resistant Terminals (transistor ( 4 inputs (NPN, + common) I/O) I/O) 4 inputs (PNP, -- common) 8 inputs (NPN, + common) 8 inputs (PNP, -- common) 4 outputs (NPN, -- ...

Page 28

J Smart DeviceNet I/O Terminals Basic Modules Product Smart I/O basic Modules automatically / y collect network status and connected device performance information device performance information 3--tier Terminal Block Types yp MIL Connector Terminal Block Types ...

Page 29

CS1 Ordering Guide DeviceNet Enhanced Products IP67 Rated Transistor Terminals with M12 Connectors Product Terminals with IP67-rated water-washdown resistance DeviceNet Enhanced Products Product Vision sensors Operator interface terminal adapter for NT31/NT631 touch screens Communications module for fiber--optic ...

Page 30

DeviceNet Enhanced Products (continued) Product Specifications Servo drive, W--series Communicate positioning commands, drive parameters, position- adapter ing data, motor characteristics etc, between the W-series servo and a DeviceNet master. Commands received via DeviceNet are output to the W-series servo drive ...

Page 31

CS1 Ordering Guide DeviceNet Multiple I/O Terminal Modules J DeviceNet Multiple I/O Terminal Modules Name Communications Unit Digital I Modules with Terminal Modules Blocks Bl k Modules with MOLEX C Connectors Modules with Fujitsu j ...

Page 32

J CompoBus/S Slave Modules Name Specifications I/O Link Modules / For CPM2C; 8 input points, 8 output points For CPM1A/CPM2A; 8 input points, 8 output points Remote I/O Terminals with Transistors / 4 input points, NPN (+ common) 4 input ...

Page 33

CS1 Ordering Guide CompoBus/S Modules CompoBus/S Slave Modules (Continued) Name Specifications Remote I/O Terminals with Transistors / 32 input points, NPN (+ common) and Connectors input points, PNP (-- common) 32 output points, NPN (-- common) 32 ...

Page 34

... Spacer --- CS1 Ordering Guide Specifications For 3-slot Backplane For 5-slot Backplane For 8-slot Backplane For 10-slot Back- plane Specifications Programmable Controller Optional Products Standards Part number --- C200H-COV11 C200H-COV02 C200H-COV03 C500-COV01 CV500-COV01 C200HW-ATT32 C200HW-ATT52 C200HW-ATT82 C200HW-ATTA2 --- G6B-1174P-FD-US C200H-ATT01 --- C200H-SP001 U, C CV500-TER01 ...

Page 35

...

Page 36

Cat. No. R301-E3-01 2/04 Specifications subject to change without notice Printed in USA ...

Related keywords