G2AK-232A-DC24 Omron, G2AK-232A-DC24 Datasheet

RELAY

G2AK-232A-DC24

Manufacturer Part Number
G2AK-232A-DC24
Description
RELAY
Manufacturer
Omron
Series
G2AKr
Datasheets

Specifications of G2AK-232A-DC24

Relay Type
General Purpose
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
0.5A @ 24VDC
Coil Type
Latching, Dual Coil
Coil Current
85mA
Coil Voltage
24VDC
Control On Voltage (max)
19.2 VDC
Mounting Type
Socket
Termination Style
Socketable
Coil Voltage Vdc Nom
24V
Contact Current Max
500mA
Contact Voltage Ac Nom
110V
Contact Voltage Dc Nom
24V
Coil Resistance
270ohm
Contact Configuration
DPDT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Control Off Voltage (min)
-
Lead Free Status / Rohs Status
 Details
Other names
G2AK232ADC24
Magnetic Latching Version of G2A Ideal for
Sequence Control
• Double-winding latch system with continuous rating.
• Terminals pulled from the respective junctions between the
• Excellent vibration/shock resistance with minimal secular
• Easy monitoring of ON/OFF operation due to the built-in
• Same outline dimensions as the standard models of G2A.
Ordering Information
Model Number Legend
1. Number of Poles (Contact Form)
2. Contact Type
3. Enclosure Construction
4. Terminal Shape
Note: 1. When placing your order, add the coil voltage rating to the model number as shown below.
G2AK-@@@@@-@
DPDT
The arc barrier equipped model is a relay designed to prevent arc short-
circuiting between phases and can be used in a circuit which has poten-
tial difference between phases. The switching power of such a circuit
with potential difference must be limited to less than
1/2 the rated load when using this Relay.
built-in diodes and set and reset coils allow the built-in diodes to
be externally connected for coil surge absorption.
decrease in latching power.
operation indicator mechanism.
Latching Relay
G2AK
Contact form
2:
3:
2:
4:
A:
1P:
2. The applicable rated voltage range can be increased by connecting an external resistor. Refer to Specifications for details.
3. Models meeting UL standards must be specified when ordering. Add "-US" after the model number.
Example: G2AK-232A 100 VAC
1
DPDT
Crossbar bifurcated
Casing
Fully sealed
Plug-in terminal
PCB terminal
2 3
http://www.ia.omron.com/
4
Arc barrier equipped model
Standard model
Arc barrier equipped model
Fully sealed model
5
6
Classification
Rated coil voltage
The fully sealed model is a relay in a gas-tight plastic enclosure and thus
exhibits stable performance in an adverse atmosphere of harmful gas,
moisture, or powdery dust.
5. Safety Breaking Mechanism
6. Approved Standards
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
G2AK-232A
G2AK-232AY
G2AK-234A
None: No
Y:
None: Standard
US:
Plug-in terminals
Arc barrier
UL-approved
Fully sealed model
G2AK-2321P
---
---
PCB terminals
1

Related parts for G2AK-232A-DC24

G2AK-232A-DC24 Summary of contents

Page 1

... Fully sealed model Note: 1. When placing your order, add the coil voltage rating to the model number as shown below. Example: G2AK-232A 100 VAC 2. The applicable rated voltage range can be increased by connecting an external resistor. Refer to Specifications for details. 3. Models meeting UL standards must be specified when ordering. Add "-US" after the model number. ...

Page 2

... External resistor Set coil Resistance Capacity 0.27 kΩ 0.5 W min. 2.7 kΩ min. 3.3 kΩ min. 1.1 kΩ min. (c)Copyright OMRON Corporation 2007 All Rights Reserved. G2AK PCB terminals PY14-0 PY14-02 --- --- Reset Max. Power consumption voltage voltage Set coil Reset coil ...

Page 3

... The electrical endurance was measured at an ambient temperature of 23°C. 6. This value was measured at a switching frequency of 60 operations per minute. http://www.ia.omron.com/ Resistive load (cosφ 0 110 VAC 0 VDC 300 m/s (c)Copyright OMRON Corporation 2007 All Rights Reserved. G2AK Inductive load (cosφ = 0.4) (L ms) 3 ...

Page 4

... Not energized Energized Shock direction 2 Unit: m/s Changes in Operating Characteristics vs. External Magnetic Field G2AK-232A 24 VDC (Mean Value) Condition: Changes in set and reset voltages are checked in the worst direction in an external even magnetic field. Set voltage Reset voltage Even magnetic field strength (Oe) http://www ...

Page 5

... PCB Terminals G2AK-2321P(Y) 0.5 2.6 21.5 max. 0.5 28.5 max. 1.8 42.5 max. with PCB Terminals G2AK-2341P 0.5 2.6 22.5 max. 0.5 29.5 max. 1.8 42.5 max. Terminal Arrangement/Internal Connections (Bottom View) RESET SET Note: Terminals (Nos. 12 and 9) are pulled from the respective junctions between the diode and set coil and between the diode and reset coil ...

Page 6

... Safety Precautions Refer to Safety Precautions for All Relays. The G2AK can be used for special purposes by utilizing its built-in diodes. When built-in diodes are not required • With the DC-coil Latching Relay, the built-in diodes become unnecessary for a circuit in which a coil operating switch is incorporated for each of the set and reset coils as shown on the right ...

Page 7

... Values will vary for different combinations of ratings and performances. In the interest of product improvement, specifications are subject to change without notice. http://www.ia.omron.com/ ■ Precautions for Correct Use Refer to Technical Guide for General-purpose Relays. (c)Copyright OMRON Corporation 2007 All Rights Reserved. C-1 ...

Page 8

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specifi ed) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords