G6SU-2G DC24 Omron, G6SU-2G DC24 Datasheet

SMT RELAY

G6SU-2G DC24

Manufacturer Part Number
G6SU-2G DC24
Description
SMT RELAY
Manufacturer
Omron
Series
G6Sr

Specifications of G6SU-2G DC24

Relay Type
Telecom
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
2A @ 30VDC
Coil Type
Latching, Single Coil
Coil Current
6.3mA
Coil Voltage
24VDC
Control On Voltage (max)
18 VDC
Mounting Type
Surface Mount
Termination Style
J Lead
Contact Form
2 Form C
Power Consumption
150 mW
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Control Off Voltage (min)
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
G6SU-2GDC24
G6SU2GDC24
Suface Mount DPDT Relay
• High dielectric withstand voltage of 2,000 VAC between coil
• Meets FCC Part 68 and Telcordia 2.5 kV surge withstand.
• European version certified for EN60950/EN41003 Supple-
• Low power consumption of 140 mW (Non-latching)
• Available in through-hole and SMT terminals.
• Tape and reel or tube packaging.
• RoHS Compliant.
Ordering Information
■ Standard Version
.
* Certified for EN60950/EN41003 Supplementary Insulation at 250 V (pollution degree 2)
Model Number Legend
1. Relay Function
2. Contact Form
Gull-wing
Inside “L”
PCB through-hole
Notes: 1. When ordering, add the rated coil voltage to the model number.
G6S
and contacts (standard type); 1,500 VAC between contacts
of different polarity.
mentary Insulation at 250 V at Pollution Degree 2.
Low Signal Relay
G6S
None: Non-latching
U:
K:
2: DPDT
Terminal
1
2. When ordering tape packing (surface mount models), add "-TR" to the model number.
3. Dual coil latching models are available with a High-sensitivity coil. (140 mW; 200 mW for DC24)
-
"-TR" is not part of the relay model number. Therefore, it is not marked on the relay case.
When ordering High-sensitivity dual coil latching models, add "-H” to the model number.
Single coil latching
Dual coil latching
Example: G6S-2F DC12
Example: G6S-2F-TR DC12
Example: G6SK-2G-H-TR DC5
2
3
-
4
DPDT
-
5
Contact form
DC
6
3. Terminal Shape
4. Approved Standards
Tape packing
Y:
None: Through-hole
F:
G:
None: UL/CSA
Model
High-sensitivity coil
Rated coil voltage
Gull-wing surface mount
(Standard coil models - 5, 12, 24 VDC )
Inside “L” surface mount
EN60950/EN41003
G6S-2F
G6S-2G
G6S-2
Standard
Non-latching
G6S-2F-Y
G6S-2G-Y
G6S-2-Y
European Version*
5. Packaging
6. Rated Coil Voltage
None: Tube packaging
TR:
3, 4.5, 5, 12, 24 VDC
Tape and reel packaging
(Surface mount models)
G6SU-2F
G6SU-2G
G6SU-2
Low Signal Relay
Single coil latching
G6SK-2F
G6SK-2G
G6SK-2
G6S
Dual coil latching
95

Related parts for G6SU-2G DC24

G6SU-2G DC24 Summary of contents

Page 1

... Tape and reel packaging Gull-wing surface mount (Surface mount models) Inside “L” surface mount 6. Rated Coil Voltage 3, 4.5, 5, 12, 24 VDC EN60950/EN41003 (Standard coil models - 5, 12, 24 VDC ) Single coil latching Dual coil latching G6SU-2F G6SK-2F G6SU-2G G6SK-2G G6SU-2 G6SK-2 G6S 95 Low Signal Relay ...

Page 2

... G6SU - Standard Single Coil Latching (G6SU-2F, G6SU-2G, G6SU-2) Rated Rated Coil voltage current resistance (VDC) (mA) (Ω) Armature OFF 3 33.3 90 0.108 4.5 22.2 203 0.27 5 20.0 250 0 ...

Page 3

... VAC, 50/60 Hz for 1 minute between contacts of same pole 500 VAC, 50/60 Hz for 1 minute between set and reset coils (G6SK) 2,500 μS) between coil and contacts for G6S and G6SU 2,500 μS) between contacts of different poles 1,500 V (10 x 160 μS) between coil and contacts for G6SK 1,500 V (10 x 160 μ ...

Page 4

... Ambient temperature (°C) Dielectric Strength (Standard Version, Non-latching) Detecting current: 1mA 1000 1500 2000 2500 3000 Breakdown voltage (V) Between coil and contacts Single Coil Latching Dual Coil Latching G6SU G6SK 12 VDC max. G6SK 24 VDC Ambient temperature (° 1000 1500 2000 2500 3000 ...

Page 5

Impulse Withstand Voltage (Standard Version, Non-latching ms 3500 4000 4500 5000 5500 6000 Breakdown voltage (V) Between coil and contacts Impulse Withstand Voltage (European version ms ...

Page 6

Dimensions Note: 1. All units are in millimeters unless otherwise indicated. 2. Coplanarity is 0.1 mm max. ■ Standard G6S-2F, G6S-2F-Y Tolerance: ±0.3 G6S-2G, G6S-2G-Y Tolerance: ±0.3 G6S-2, G6S-2-Y Tolerance: ±0.3 G6S 100 Low Signal Relay Terminal Arrangement/ Footprint Internal ...

Page 7

... Single Coil Latching G6SU-2F Tolerance: ±0.3 G6SU-2G Tolerance: ±0.3 G6SU-2 Tolerance: ±0.3 Terminal Arrangement/ Internal Connections (Top View) 7.3+0.2 Orientation mark Terminal Arrangement/ 7.3+0.2 Internal Connections (Top View) Orientation mark Terminal Arrangement/ Internal Connections (Bottom View) Orientation mark Low Signal Relay ...

Page 8

Dual Coil Latching G6SK-2F Tolerance: ±0.3 G6SK-2G Tolerance: ±0.3 G6SK-2 Tolerance: ±0.3 Recommended Soldering Method (1) IRS Method (Mounting Solder: Lead) Soldering Soldering 220 to 240 180 to 200 Preheating Preheating 150 90 to 120 Time ...

Page 9

... When ordering, add “TR” before the rated coil voltage (e.g., G6S-2F-TR-DC12) Note not part of the relay model number and will not be marked on the relay. 29.5±1.0 G6S-2F, G6SU-2F, G6SK-2F, G6S-2F-Y 25.5±0.5 330 80 G6S-2G, G6SU-2G, G6SK-2G, G6S-2G-Y Coil rating Contact ratings VDC VDC (Resistive) 0 110 VDC (Resistive VDC ...

Page 10

Precautions • Use a DC power supply with 5% or less ripple factor to operate the coil. • Do not use the G6S where subject to strong external magnetic fields. • Do not use the G6S where subject to magnetic ...

Page 11

... Seller within 30 days of receipt of shipment. III. PRECAUTIONS 1. Suitability THE BUYER’S SOLE RESPOINSIBILITY TO ENSURE THAT ANY OMRON PRODUCT IS FIT AND SUFFICIENT FOR USE IN A MOTORIZED VEHICLE APPLICATION. BUYER SHALL BE SOLELY RESPONSIBLE FOR DETERMINING APPROPRIATENESS OF THE PARTICULAR PRODUCT WITH RESPECT TO THE BUYER’ ...

Page 12

... THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website at http://www.components.omron.com – under the “About Us” tab, in the Legal Matters section. ...