S82Y-D60S Omron, S82Y-D60S Datasheet

no-image

S82Y-D60S

Manufacturer Part Number
S82Y-D60S
Description
S82D-600w SIDE BRACKET
Manufacturer
Omron
Series
S82Dr
Datasheets

Specifications of S82Y-D60S

Accessory Type
Mounting Bracket(s)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
S82D-60xx Power Supply
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
S82YD60S
High-Grade Power Supply for
Demanding Industrial Applications
D
D
D
D
D
D
D
D
Ordering Information
J SWITCHING POWER SUPPLIES
Stock Note: Shaded models are normally stocked.
Note: For mounting brackets and other accessories, refer to the Accessories Section on the next page.
J MODEL NUMBER LEGEND
S82D -
Rated input voltage
Rated input voltage
120/240VAC
120/240VAC
Wide range of output voltages: 5 V or 12 V.
Selectable 85 to 132 VAC or
170 to 264 VAC input voltage.
Equipped with overvoltage and overload protection,
remote sensing and remote control functions.
Fan alarm signal warns of possible fan malfunction.
For loads drawing high current, parallel connection of
two power supplies possible.
Two pairs of output terminals simplify wiring of two
loads (300 W).
Optional multiple output terminal available (600 W).
3-year warranty.
S82D
Switching Power Supply
1
2
Power ratings
Power ratings
300 W
300 W
600 W
600 W
1. Power ratings
30: 300 W
60: 600 W
Output
Voltage
5 VDC
12 VDC
5 VDC
12 VDC
2. Output voltage
05: 5 V
12: 12 V
24: 24 V
Switching Power Supply
Current
60 A
27 A
120 A
53 A
Part number
Part number
S82D-3005
S82D-3012
S82D-6005
S82D-6012
S82D
1

Related parts for S82Y-D60S

S82Y-D60S Summary of contents

Page 1

Switching Power Supply S82D High-Grade Power Supply for Demanding Industrial Applications Wide range of output voltages Selectable 85 to 132 VAC or D 170 to 264 VAC input voltage. Equipped with overvoltage and overload ...

Page 2

... Relay output, connector SPST, 250 VAC load resistance, but switching capacity is 125 VA Yes Yes Yes (This table continues on the next page.) S82D Part number S82Y-D30B S82Y-D60B S82Y-D30S S82Y-D60S S82Y-D60T S82Y-D30A S82Y-D60A S82Y-DFAN S82Y-DFAN 600 max max typ typ. ...

Page 3

Specifications Table – continued from previous page Power rating Characteristics Ambient temperature Ambient temperature Operating Storage Ambient humidity Ambient humidity Operating Storage Dielectric strength (see note below table) Insulation resistance (see note below table) Vibration resistance Shock resistance Output indicator ...

Page 4

J OVERLOAD PROTECTION The protective function prevents damage to the load as well as to the power supply itself due to overload. If the load current rises above the overload set value (105% to 135% of the rated load current), ...

Page 5

Nomenclature Output Terminals: Connect load wiring. 2. Input Terminals: Connect input wiring. 3. Voltage Select Terminals: Switch the input ...

Page 6

Operation J REMOTE SENSING FUNCTION This function corrects a voltage drop in the load wiring. When using the remote sensing function, remove the short bars from the remote sensing terminals as shown in the following diagram. Remote sensing connection (2-wire ...

Page 7

J SWITCHING THE INPUT VOLTAGE BETWEEN 120 V AND 240 V • Select 100 to 120 or 200 to 240 V input voltage by shorting or opening the input voltage switching terminals, as shown in the diagram below. (Factory set ...

Page 8

... Power supply Connection kit S82D-300 W S82Y-D30A S82D-600 W S82Y-D60A Wiring Specifications When using lead wires, the wires should meet the specifications in the following table. Model Cross sectional area 2 S82D-3005 14 mm min ...

Page 9

Dimensions Unit: mm (inch) J SWITCHING POWER SUPPLIES S82D-30jj (300 W) M3 terminal screw 92 (3.62) M4 terminal screw S82D-60jj (600 W) 190 (7.48) 92 (3.62) M4 terminal screw 30 max. 4 max. 120 190 (7.48) (4.72) M5 terminal Eight, ...

Page 10

... Unit: mm (inch) J MOUNTING BRACKETS (ORDER SEPARATELY) Bottom Mounting S82Y-D30B for S82D-30jj (5.91) S82Y-D60B for S82D-60jj Side Mounting S82Y-D30S for S82D-30jj 15 32 122 (4.80) 55 S82Y-D60S for S82D-60jj 122 (4.80 Switching Power Supply 190 (7.48) 160 150 138 100 Four, 4.5-dia holes Four, 4.5-dia. holes countersunk at 90_ 200 (7 ...

Page 11

... J REPLACING THE FAN Fan Alarm • necessary to replace the internal fan when the fan alarm output goes ON. Note: Replacement fan S82Y-DFAN can be ordered through your dealer. • To replace the fan, remove the back cover as shown in the diagram below. Connector for ...

Page 12

... Seller hereby objects to any terms or conditions proposed in Buyer’s purchase order or other documents which are inconsistent with addi- tion to, these Terms. Please contact your Omron representative to confirm any additional terms for sales from your Omron company. 2. Prices. All prices stated are current, subject to change without notice by Seller ...