Product data sheet
Characteristics
Apr 2, 2012
XPSATE5110P
module XPSAT - Emergency stop - 24 V DC
Main
Range of product
Preventa Safety automation
Product or component
Preventa safety module
type
Safety module name
XPSATE
Safety module applica-
For emergency stop and switch monitoring
tion
Function of module
Emergency stop button with 2 NC contacts
Safety level
Can reach PL d/category 3 conforming to EN/ISO
13849-1 time delay safety outputs
Can reach PL e/category 4 conforming to EN/ISO
13849-1 instantaneous safety outputs
Can reach SILCL 3 conforming to EN/IEC 62061 in-
stantaneous safety outputs
Can reach SILCL 2 conforming to EN/IEC 62061
time delay safety outputs
Safety reliability data
DC > 99 % conforming to EN/ISO 13849-1 instanta-
neous safety outputs
MTTFd = 134.8 years conforming to EN/ISO
13849-1 instantaneous safety outputs
MTTFd = 54.5 years conforming to EN/ISO 13849-1
time delay safety outputs
DC > 98.4 conforming to EN/ISO 13849-1 time delay
safety outputs
PFHd = 6.81E-9 1/h conforming to EN/IEC 62061 in-
stantaneous safety outputs
PFHd = 1.96E-8 1/h conforming to EN/IEC 62061
time delay safety outputs
Type of start
Configurable
Connections - terminals
Captive screw clamp terminals, removable terminal
block (1 x 0.2...1 x 2.5 mm²)flexible cable with cable
end, with double bezel
Captive screw clamp terminals, removable terminal
block (1 x 0.2...1 x 2.5 mm²)solid cable with cable
end, with double bezel
Captive screw clamp terminals, removable terminal
block (1 x 0.25...1 x 2.5 mm²)flexible cable with cable
end, with double bezel
Captive screw clamp terminals, removable terminal
block (2 x 0.2...2 x 1 mm²)solid cable with cable end,
with double bezel
Captive screw clamp terminals, removable terminal
block (2 x 0.2...2 x 1.5 mm²)flexible cable with cable
end, with double bezel
Captive screw clamp terminals, removable terminal
block (2 x 0.25...2 x 1 mm²)flexible cable with cable
end, with double bezel
Captive screw clamp terminals, removable terminal
block (2 x 0.5...2 x 1.5 mm²)flexible cable with cable
end, with double bezel
Output type
Relay instantaneous opening 2 NO, volt-free
Relay time delay opening 3 NO, volt-free
Number of additional
3 solid state outputs
circuits
[Us] rated supply volt-
24 V DC (- 15...10 %)
age
1

XPSATE5110P Summary of contents

  • Page 1

    ... Product data sheet Characteristics Apr 2, 2012 XPSATE5110P module XPSAT - Emergency stop - Main Range of product Preventa Safety automation Product or component Preventa safety module type Safety module name XPSATE Safety module applica- For emergency stop and switch monitoring tion Function of module Emergency stop button with 2 NC contacts ...

  • Page 2

    Complementary Synchronisation time between inputs Supply frequency Power consumption in W Input protection type Time delay Control circuit voltage Breaking capacity Breaking capacity Output thermal current [Ith] conventional free air thermal current Associated fuse rating Minimum output current Minimum output ...

  • Page 3

    ... Product data sheet Dimensions Drawings Dimensions XPSATE5110P 3 ...

  • Page 4

    ... Product data sheet Connections and Schema Wiring Diagrams Refer to the Instruction Sheet To download the instruction sheet, follow below procedure: 1 Click on Download & Documents. 2 Click on Instruction sheet. 4 XPSATE5110P ...