VF4-45H11-S05 Tyco Electronics, VF4-45H11-S05 Datasheet - Page 5

Automotive Relay

VF4-45H11-S05

Manufacturer Part Number
VF4-45H11-S05
Description
Automotive Relay
Manufacturer
Tyco Electronics
Datasheet

Specifications of VF4-45H11-S05

Coil Voltage Vdc Nom
24V
Coil Resistance
360ohm
Contact Configuration
SPDT
Relay Terminals
Quick Connect
Terminal Type
Quick Connect
No. Of Poles
1
Contact Carrying Power
1.6W
Carry Current
60A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
56
Mechanical Data
Cover retention
Terminals
Enclosures
1)
Environmental Conditions
Temperature range, storage
Test
Climatic cycling with condensation
Temperature cycling
Damp heat
Corrosive gas
Vibration resistance
Shock resistance
Load dump
Jump start
Drop test
Flammability
Overload current for relays with rated
currents as shown in contact data table
1)
2)
Values apply 2 mm from the end of the terminal. When the force is removed, the terminal must not have moved by more than 0.3 mm.
FMVSS: Federal Motor Vehicle Safety Standard.
Current and time are compatible with circuit protection by a typical automotive fuse. Relay will make, carry and break the specified current.
Axial force
Pull force
Push force
Pull force
Push force
Resistance to bending, force applied to front
Resistance to bending, force applied to side
Torsion
Dust cover
cyclic
constant
2)
Plug-In Relays
Mini ISO Relays
Power Relay F4 / VF4
All specifications subject to change. Consult Tyco Electronics for latest specifications.
Relevant standard
ISO 7637-1 (12 V)
ISO 7637-2 (24 V)
EN ISO 6988
IEC 68-2-14
IEC 68-2-30
IEC 68-2-42
IEC 68-2-43
IEC 68-2-27 (half sine form single pulses)
IEC 68-2-3
Refer to Storage in the “Glossary” catalog page 23 or http://relays.tycoelectronics.com/appnotes/
IEC 68-2-6 (sine sweep)
Capable of meeting specifications after 1.0 m (3.28 ft) drop onto concrete
24 V for 5 minutes conducting nominal current at 23°C
1 ±0.3 cm
Protects relay from dust. For use in passenger compartment or enclosures
10 ±2 cm
Testing as per
Db, Variant 1
Test pulse 5
Test pulse 5
UL94-HB or better (meets FMVSS 302)
Nb
Ca
3
3
/m
/m
1.35 x Rated current 1800 s
3.50 x Rated current 0.5 s
6.00 x Rated current 0.1 s
2.00 x Rated current 5 s
3
3
SO
H
2
S
2
Vs = +86.5 V
Vs = +200 V
10 - 500 Hz
Dimension
10 cycles
min. 20 g
6 cycles
6 cycles
min. 5 g
56 days
10 days
10 days
0.3 Nm
10 N
10 N
11 ms
150 N
150 N
150 N
100 N
100 N
1)
1)
1)
Upper air temperature 55°C
–40/+85°C (5°C per min)
switching state > 10 μs
Valid for NC contacts,
significantly higher
NO contact values
No change in the
Storage 8/16 h
Catalog 1308028-2
Comments
Revised 4-2009

Related parts for VF4-45H11-S05