■ OMRON Function Block Library for E5CN and E5CN-U-series Temperature Controller Serial
Note: These OMRON Function Block can be used for only serial port 2 (the port on the right) for CP1H and CP1L-M30/-M40/-M60 CPU Units.
■ OMRON Function Block Library for E5AR and E5ER-series Temperature Controller Serial
Note: These OMRON Function Block can be used for only serial port 2 (the port on the right) for CP1H and CP1L-M30/-M40/-M60 CPU Units.
■ OMRON Function Block Library for E5ZN-series Temperature Controller Serial
Note: These OMRON Function Block can be used for only serial port 2 (the port on the right) for CP1H and CP1L-M30/-M40/-M60 CPU Units.
_E5xx003_Stop
_E5xN004_ExecuteAT
_E5xN005_CancelAT
_E5xx200_ReadVariable
_E5xx201_ReadStatus
_E5xx202_ReadPV
_E5xx203_ReadSP
_E5xx204_ReadCoolingMV
_E5xx205_ReadHeatingMV
_E5xx400_WriteVariable
_E5xx403_WriteSP
_E5xx600_SetComm
_E5xx003_Stop
_E5xN004_ExecuteAT
_E5xN005_CancelAT
_E5xx200_ReadVariable
_E5xx201_ReadStatus
_E5xx202_ReadPV
_E5xx203_ReadSP
_E5xx204_ReadCoolingMV
_E5xx205_ReadHeatingMV
_E5xxR206_ReadValveOpening
_E5xx400_WriteVariable
_E5xx403_WriteSP
_E5xx600_SetComm
_E5xx001_ExeOperation
_E5xx002_Run
_E5xx003_Stop
_E5xN004_ExecuteAT
_E5xN005_CancelAT
_E5xx200_ReadVariable
_E5xx201_ReadStatus
_E5xx202_ReadPV
_E5xx203_ReadSP
_E5xx204_ReadCoolingMV
_E5xx205_ReadHeatingMV
_E5xx400_WriteVariable
_E5xx403_WriteSP
_E5xx600_SetComm
OMRON Function Block Library
Communications
Communications
Communications
They can be used for serial port 1 only on CP1L-L14/-L20 CPU Units (which have only one serial port).
Cannot be used for the CP1L-L10.
They can be used for serial port 1 only on CP1L-L14/-L20 CPU Units (which have only one serial port).
Cannot be used for the CP1L-L10.
They can be used for serial port 1 only on CP1L-L14/-L20 CPU Units (which have only one serial port).
Cannot be used for the CP1L-L10.
FB name
FB name
FB name
Stop
Execute AT
Cancel AT
Read variable
Read status
Read PV
Read SP
Read cooling MV
Read heating MV
Write variable
Write SP
Set communications
Stop
Execute AT
Cancel AT
Read variable
Read status
Read PV
Read SP
Read cooling MV
Read heating MV
Read valve opening
Write variable
Write SP
Set communications
Execute command
Run
Stop
Execute AT
Cancel AT
Read variable
Read status
Read PV
Read SP
Read cooling MV
Read heating MV
Write variable
Write SP
Set communications
Function name
Function name
Function name
Stops operation for Temperature Controller channels.
Starts AT for Temperature Controller channels.
Cancels AT for Temperature Controller channels.
Reads one item in specified variable area.
Reads status of specified Temperature Controller channel.
Reads PV of specified Temperature Controller channel.
Reads SP of specified Temperature Controller channel.
Reads cooling MV of specified Temperature Controller channel.
Reads heating MV of specified Temperature Controller channel.
Reads valve opening monitor value of specified Temperature Controller channel.
Writes one data item to specified variable area.
Sets SP for specified Temperature Controller channel.
Sets PLC serial port to initial communications settings of Temperature Controller.
Stops operation for Temperature Controller channel.
Starts AT for Temperature Controller channel.
Cancels AT for Temperature Controller channel.
Reads one item from specified variable area.
Reads status of specified Temperature Controller channel.
Reads PV of specified Temperature Controller channel.
Reads SP f specified Temperature Controller channel.
Reads cooling MV of specified Temperature Controller channel.
Reads heating MV of specified Temperature Controller channel.
Writes one data item to specified variable area.
Sets SP for specified Temperature Controller channel.
Sets PLC serial port to default communications settings of Temperature Controller.
Executes specified command.
Starts operation for specified Temperature Controller channel.
Stops operation for specified Temperature Controller channel.
Starts AT for Temperature Controller channels.
Cancels AT for Temperature Controller channels.
Reads one item in specified variable area.
Reads status of specified Temperature Controller channel.
Reads PV of specified Temperature Controller channel.
Reads SP of specified Temperature Controller channel.
Reads cooling MV of specified Temperature Controller channel.
Reads heating MV of specified Temperature Controller channel.
Writes one data item to specified variable area.
Sets SP for specified Temperature Controller channel.
Sets PLC serial port to default communications settings of Temperature Controller.
Description
Description
Description
63