CP1W-20EDT Omron, CP1W-20EDT Datasheet - Page 29

no-image

CP1W-20EDT

Manufacturer Part Number
CP1W-20EDT
Description
Expansion 12 In, 8 Out NPN
Manufacturer
Omron
Datasheet

Specifications of CP1W-20EDT

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
42
CPU Unit Specifications
■ Serial Communications Specifications (CP1W-CIF01/-CIF11)
Note: 1. Serial PLC Link can be used with either serial port 1 or serial port 2.
■ Ethernet Communications Specifications (CP1W-CIF41)
Note: 1. CX-Programmer version 8.1 or higher (CX-One version 3.1 or higher) is required.
Peripheral USB port
Serial port 1
(Option board slot 1)
Serial port 2
(Option board slot 2)
Item
Applicable PLCs
Number of Units that can be mounted
Transfer
Item
Number of nodes
Message length
Size of buffer
Communications Function
FINS/UDP
method
FINS/TCP
method
2. CP1L CPU Units only.
2. Use CX-Integrator version 2.33 or higher (CX-One version 3.1 or higher) when the system needs to be set the routing tables. However, CX-Integrator does
3. To connect the CP1H/CP1L CPUs with the NS-series Programmable Terminals via Ethernet using CP1W-CIF41, make sure that the system version of NS
not support the other functions, using CP1W-CIF41, such as transferring the parameters and network structure.
Series is 8.2 or higher.
Item
Media access method
Modulation method
Transmission paths
Baud rate
Transmission media
Transmission Distance
Protocol used
Port number
Protection
Protocol used
Number of connections
Port number
Protection
CP1H
Yes
Yes
Yes
CP1L-M Type CP1L-L14/L20
100 Mbit/s
10 Mbit/s
Applicable CPU Units
Yes
Yes
Yes
CP1H/CP1L CPU Units
Note: The Ethernet Option Board cannot be used for the CP1L-L10.
1 set. (each type of micro PLC can only mount 1 set Ethernet Option Board)
CSMA/CD
Baseband
Star form
100 Mbit/s (100Base-TX), 10 Mbit/s (10Base-T)
• Unshielded twisted-pair (UDP) cable
• Shielded twisted-pair (STP) cable
• Unshielded twisted-pair (UDP) cable
• Shielded twisted-pair (STP) cable
100 m (distance between hub and node)
254
1016 bytes max.
8k
FINS Communications Service (UDP/IP, TCP/IP)
UDP/IP
9600 (default) Can be changed.
No
TCP/IP
Up to 2 simultaneous connections and only one connection can be set to client
9600 (default) Can be changed.
Yes (Specification of client IP addresses when unit is used as a server)
Categories: 5, 5e
Categories: 100 Ω at 5, 5e
Categories: 3, 4, 5, 5e
Categories: 100 Ω at 3, 4, 5, 5e
Yes
Yes
---
CP1L-L10
Yes
---
---
FINS Communications Service Specifications
For connecting
Peripheral Device.
Host Link, No-protocol,
NT Link (1: N),
Serial PLC Link
(See note 1.),
Serial Gateway
(CompoWay/
F master,
Modbus-RTU master),
Modbus-RTU easy
master function
NT Link (1: 1) (See note 2.)
1: 1 Link (See note 2.)
Function
Specifications
Conforms to USB 1.1, B-type connector
The following can be used for either port.
CP1W-CIF01 RS-232C Option Board
CP1W-CIF11
RS-422A/485 Option Board
(Maximum transmission
distance 50m)
CP1W-CIF12
RS-422A/485(Isolated-type)
Option Board
(Maximum transmission
distance 500m)
Can be used with either port.
Interface
COMM
COMM

Related parts for CP1W-20EDT