H3DEHACDC24S Omron, H3DEHACDC24S Datasheet

no-image

H3DEHACDC24S

Manufacturer Part Number
H3DEHACDC24S
Description
TIMER DIN MNT 22.5mm
Manufacturer
Omron
Datasheet

Specifications of H3DEHACDC24S

Lead Free Status / RoHS Status
Compliant
DIN Track Mounted, Standard 22.5-mm Width Timer Range
• A wide AC/DC power supply range (24 to 230 VAC/DC) reduces the number of timer models kept in stock. (except for H3DE-H)
• 12-VDC model available for a specific application. (H3DE-M2)
• Nameplate provided for easy timer identification and management.
• Terminal clamp left open when delivered.
• Finger protection terminal block to meet VDE0106/P100.
• Enables easy sequence checks through instantaneous outputs for a zero set value at any time range.
• Incorporates environment-friendly, cadmium-free contacts. (except for H3DE-H)
• High immunity to inverter noise.
• Approved by UL and CSA.
• Conforms to EN61812-1 and IEC60664-1 4 kV/2 for Low Voltage, and EMC Directives.
■ Broad Line-up of H3DE Series
Solid-state Timer
H3DE
Standard Timer
H3DE-M
H3DE-S
H3DE-M/S
Solid-state Timer
Common to ALL Timers
H3DE-M/-S......................................................................................................................................
H3DE-F ...........................................................................................................................................
H3DE-G ..........................................................................................................................................
H3DE-H...........................................................................................................................................
Accessories.....................................................................................................................................
Precautions .....................................................................................................................................
Twin Timer
H3DE-F
H3DE-F
Contents
H3DE
Star-delta Timer
H3DE-G
H3DE-G
Power OFF-delay Timer
H3DE-H
12
18
24
30
31
H3DE-H
2
CSM_H3DE_DS_E_3_1
1

Related parts for H3DEHACDC24S

H3DEHACDC24S Summary of contents

Page 1

Solid-state Timer H3DE DIN Track Mounted, Standard 22.5-mm Width Timer Range • A wide AC/DC power supply range (24 to 230 VAC/DC) reduces the number of timer models kept in stock. (except for H3DE-H) • 12-VDC model available for a ...

Page 2

Solid-state Multi-functional Timer H3DE-M/-S • Eight operating modes (H3DE-M) and four operating modes (H3DE-S) cover a wide range of applications. • Programmable contact enables the building of a self-holding re- lay circuit (-@2 models). • A wide time setting range ...

Page 3

Specifications ■ General Item H3DE-M2 Operating mode A: ON-delay (Signal or Power) B: Flicker OFF start (Signal or Power) B2: Flicker ON start (Signal or Power) C: Signal ON/OFF-delay D: Signal OFF-delay E: Interval (Signal or Power) G: Signal ON/OFF-delay ...

Page 4

Characteristics Accuracy of operating ±1% max (±1% ±10 ms max. at 1.2-s range) (see note 1) time Setting error ±10% ±50 ms max (see note 1) Signal input time 50 ms min. (see note 1) ...

Page 5

Connections ■ Block Diagram H3DE-M1/-M2 AC (DC) input Power supply circuit H3DE-S1/-S2 AC (DC) input Power supply circuit ■ I/O Functions Item Input Start Starts operation. Output Control output Outputs are turned ON according to designated out- put mode when ...

Page 6

Terminal Arrangement H3DE-M1 H3DE- (see note 25/ ...

Page 7

Operation ■ Basic Operation Setting of Selector The selectors can be turned clockwise and counterclockwise to select the desired time unit, time scale, or operating mode. Each selector has a snap mechanism that secures the selector at a given position. ...

Page 8

Timing Chart Note: 1. The minimum power reset time is 0.1 s and the minimum signal input time is 0. The letter “t” in the timing charts stands for the set time and “t–a” means that the ...

Page 9

Operating mode D: t Signal OFF- Power (A and delay Start (B and (see note) Output relay and 16 (25 and 26) Output relay: NO (output indicator) 15 and ...

Page 10

Nomenclature Time scale display window Time scale selector (select 0 Output indicator (orange) (Lit while Timer gives output.) Operating mode selector (select a mode from B2 and G for the H3DE-M1/-M2, from ...

Page 11

... To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. H3DE-M/-S Terminal block (black) Surface color: Light gray 5Y7/1 (OMRON) Output type selector switch (default setting: Time-limit output) Terminal block (black) 11 ...

Page 12

Solid-state Twin Timer H3DE-F • Operates in flicker-OFF or flicker-ON start mode with one Unit. • Independent ON- and OFF-time settings. Combinations of long ON- or OFF-time and short OFF- or ON- time setting are possible. • Long time range ...

Page 13

Specifications ■ General Item Operating mode Flicker-OFF/Flicker-ON start Operating/Reset method Time-limit operation/Time-limit reset or self-reset Terminal block Clamps two 2.5 mm Terminal screw tightening torque 0.98 N·m max. {approx. 10 kgf·cm max.} Output type Relay: SPDT Mounting method DIN track ...

Page 14

Characteristics Accuracy of operating time ±1% max (±1% ±10 ms max. at 1.2-s range) Setting error ±10% ± 0.05 s max Influence of voltage ±0.5% max (±0.5% ±10 ms max. at 1.2-s range) ...

Page 15

Connections ■ Block Diagram ON indicator AC (DC) input Power supply circuit ■ I/O Function Inputs --- Outputs Control output Outputs are turned ON/OFF according to the time set by the ON-and OFF-time setting dial. ■ Terminal Arrangement Note: DC ...

Page 16

Operation ■ Basic Operation Time Unit Selection The time unit display window for output ON is located on the upper- right side of the front panel above the corresponding time unit selec- tor. The time unit display window for output ...

Page 17

... OFF-time unit selector (select one from s, 10s, min OFF-time unit display window (Front View) ON/OFF Start Selector Switch Settings Setting Operating mode Flicker-ON start Flicker-OFF start (Bottom View) Terminal block (black) Terminal block (black) H3DE-F Surface color: Light gray 5Y7/1 (OMRON) 17 ...

Page 18

Solid-state Star-delta Timer H3DE-G • A wide star-time range (up to 120 seconds) and star-delta trans- fer time range (up to 0.5 seconds) Model Number Structure ■ Model Number Legend H3DE - Star-delta timer Ordering Information ■ ...

Page 19

Specifications ■ General Item Operating mode Star-delta operation Operating/Reset method Time-limit operation/Self-reset Terminal block Clamps two 2.5 mm Terminal screw tightening torque 0.98 N·m max. {approx. 10 kgf·cm max.} Output type (Star operation circuit) Relay: SPDT (Delta operation circuit) Relay: ...

Page 20

Characteristics Accuracy of operating time ±1% max Setting error ±10% ± 0.05 s max Total tolerance of transfer ± (25 ms) max. time Influence of voltage ±0.5% max Influence of ...

Page 21

Connections ■ Block Diagram AC (DC) input Star operation Power time supply oscillation circuit circuit ■ I/O Functions Inputs Outputs Control output ■ Terminal Arrangement Note: DC supply voltage does not require the designation of polarity. Star Star-delta operation transfer ...

Page 22

Operation ■ Basic Operation Time Unit Setting The star-delta transfer time is set to 0.05, 0.1, 0.25 or 0.5 with the star-delta transfer time selector on the lower-right side of the front panel and the set value appears in the ...

Page 23

... H3DE-G ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. Terminal block (black) Surface color: Light gray 5Y7/1 (OMRON) Terminal block (black) H3DE-G 23 ...

Page 24

Solid-state Power OFF-delay Timer H3DE-H • Two delay-time models available. 0 seconds (S Series 120 seconds (L Series) • Covers wide range of supply voltage. Model Number Structure ■ Model Number Legend H3DE - 1 1. ...

Page 25

Specifications ■ General Item Operating mode Power OFF-delay Operating/Reset method Instantaneous operation/Time-limit reset Terminal block Clamps Two 2.5 mm Terminal screw tightening torque 0.98 N·m max. {approx. 10 kgf·cm max.} Output type Relay: SPDT Mounting method DIN track mounting (see ...

Page 26

Characteristics Accuracy of operating time ±1% max (±1% ±10 ms max. at 1.2-s range) Setting error ±10% ± 0.05 s max Influence of voltage ±0.5% max (±0.5% ±10 ms max. at 1.2-s range) ...

Page 27

Connections ■ Block Diagram AC (DC) input Power supply circuit Power failure detection circuit ■ I/O Functions Inputs --- Outputs Control output The Timer operates instantaneously when the Timer is turned ON. The Timer is in counting operation after the ...

Page 28

Operation ■ Basic Operation Time Scale Selection The time scale selector on the upper left-hand side of the front panel of the S Series can be set to 0 and that of the L Series can be set ...

Page 29

... H3DE-H ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. Terminal block (black) Surface color: Light gray 5Y7/1 (OMRON) Terminal block (black) H3DE-H 29 ...

Page 30

Accessories (Order Separately) (Common) Note: The following is common for all H3DE models. Note: All units are in millimeters unless otherwise indicated. ■ Dimensions Mounting Track PFP-100N, PFP-50N 7.3±0.15 4 ...

Page 31

Safety Precautions (Common) Refer to Safety Precautions for All Timers. Note: The following is common for all H3DE models. ■ Changing of Setting !CAUTION Do not change the time unit, time scale, operating mode, or output type selector switch while ...

Page 32

Switching Current vs. Ambient Temperature (When Mounting Two or More H3DE Units Side-by-Side) 70 Mounting clearance Mounting 40 clearance Mounting 30 clearance Load current ( ...

Page 33

Operation (H3DE-H) An interval minimum is required to turn on the H3DE after the H3DE is turned off. If the H3DE is turned on and off repeatedly with an interval of shorter than 3 s, the ...

Page 34

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...