the Board mounted to the PLC.
Refer to Appendix 8 Standard Models for details on the Units that can be connected to NS-
series PTs as hosts using RS-232C or RS-422A communications in a 1:1 NT Link.
• Supported RS-422A Host Units
Units for RS-422A communications with a built-in 1:1 NT Link function vary according to the
type and series of OMRON PLC used.
• C200HX/HG/HE(-Z) PLCs can be connected in a 1:1 NT Link for RS-422A by adding a
• CQM1H PLCs can be connected in a 1:1 NT Link for RS-422A by adding a Serial Com-
Check the series and type of the PLC and the model of the Board that is mounted to the PLC
when connecting the PT to the host.
Refer to Appendix 8 Standard Models for details on the Units that can be connected to NS-
series PTs as hosts and support a 1:1 NT Link using RS-422A.
Reference
• Connecting to CPM2C PLCs
The CPM2C has a single connector that is the same shape as a CS-series peripheral port.
Internally, the connector has signal lines that are for use with the CPU’s built-in RS-232C
port and the peripheral port. Therefore, when using the CPM2C, use the settings for the
CPU’s built-in RS-232C port or for the peripheral port according to the converter cable and
port used. When using a CPM2C1-CIF21 Simplified Communications Unit, connect it to the
RS-232C port. Use CS1W-CN118 Connecting Cable to connect the CPM2C to the NS-series
PT using the built-in RS-232C port of the CPM2C. The peripheral port cannot be used to
connect the PT.
Refer to the CPM2C Operation Manual (Cat. No. W356) for details.
Reference
CS1W-CN118 port (D-Sub 9-pin)
RS-232C port
(D-Sub 9-pin female)
CS1W-CN118
Communications Board.
munications Board.
Port for connecting PT
CS/CJ series CPU Units cannot be connected in a 1:1 NT Link. Use a 1:1 connection
through 1:N NT Links (normal or high speed). For details, refer to 1:N NT Links or High-
speed 1:N NT Links in Section 4-2 1:N Host Connection.
The 1:1 NT Link is not supported for RS-485 (two-wire) communications. Always use RS-422A
(four-wire). NS-series RS-485 (two-wire) communications are used to connect to an OMRON Tem-
perature Controller. The NS-AL002 cannot be used with the NT-series PTs or PLCs.
CPM2C
Set for built-in RS-232C.
PLC Setup
4-1 1:1 Host Connection
4-3