6-2-4
Initializing and Saving the Operation Log
Initialize or save the operation log by using operations from the Initialize Tab Page in the Sys-
tem Menu, as follows:
This function initializes or saves the operation log saved in the PT.
Up to 1,024 operations can be recorded in order of occurrence.
Use this function when screen data has been changed, for initializing log data, or for saving
log data as a CSV file in the Memory Card.
The operation log is used to record the number of times the following operations are per-
formed and the order in which they occur.
• Functional object operation history
• Screen display history
• Macro execution history
• Communications address (bit) value change history
Refer to 2-4 System Memory in the PT Programming Manual for details.
Reference
• The functional objects that can be recorded are ON/OFF buttons, word buttons, Nu-
• The following methods can also be used to initialize operation log data with an NS-
• The operation log will be deleted when project data or system programs are down-
• The following methods can be used to save operation log data with an NS-series PT.
meral Display & Input, String Display & Input, thumbwheel switches, data block tables,
and Multifunction Objects.
series PT.
loaded.
• Turn ON $SB37 in system memory from the host.
• Execute a Multifunction Object set to initialize the operation log.
• For details on how to execute Multifunction Objects that have the operation log
• Press the Operation Log (Sort by Occurrence) Button or Operation Log (Sort
• Turn ON $SB38 in system memory from the host.
• For details on how to execute Multifunction Objects that have the operation log
data initialization function set, refer to the NS-series PT Programming Manual.
by Frequency) Button in the System Menu.
data initialization function set, refer to the NS-series PT Programming Manual.
6-2 Initializing and Saving Data and Removing the Memory Card
6-15