3-6 Using Memory Cards
3-30
Error Messages Requiring Checking
After checking the message, reset the PT, and transfer the data again.
It may not be possible to replace the system program using a normal download if the PT sys-
tem has been damaged, e.g., if the power was turned OFF while a file was being written.
Use the following procedure to operate the PT if system program replacement is not possible
or the system program is damaged and the PT does not start.
Select Programs – Omron - CX-One - CX-Designer - Most Recent NS-series PT Up-
date/Recovery Program from the Windows Start Menu.
Memory Card Error
Could not recognize a Memory Card.
Check the Memory Card and reset the NS
Hardware.
Project Transmission Error
Transmission Failed.
Check the Memory Card and reset the NS
Hardware.
System Transmission Error
Transmission Failed.
Check the Memory Card and reset the NS
Hardware.
Cannot find source data.
Are you sure to continue Download-
ing/Uploading?
The password is incorrect. Check the pass-
word. Reset the PT.
System Program Recovery/Update
Error message
• Is the Memory Card inserted into the PT?
• Is the Memory Card damaged?
• Was the Memory Card removed during data trans-
• Is the free space on the Memory Card insufficient?
• Is the Memory Card damaged?
• Does the screen data volume exceed the memory
• Does the transfer source directory or file exist?
• Check whether the password is correct.
fer?
capacity of the PT?
(Note: If the Yes Button is pressed and data is
transferred, the previous data at the transfer desti-
nation will be deleted.)
Check item